Cargando…

Tangential intensity modulated radiation therapy (IMRT) to the intact breast

INTRODUCTION: Inverse‐planned intensity modulated radiation therapy (IP‐IMRT) has potential benefits over other techniques for tangential intact breast radiotherapy. Possible benefits include increased homogeneity, faster planning time, less inter‐planner variability and lower doses to organs at ris...

Descripción completa

Detalles Bibliográficos
Autores principales: Dean, Jenna, Hansen, Carmen J., Westhuyzen, Justin, Waller, Brett, Turnbull, Kirsty, Wood, Maree, Last, Andrew
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5167335/
https://www.ncbi.nlm.nih.gov/pubmed/27741382
http://dx.doi.org/10.1002/jmrs.185
_version_ 1782483161843761152
author Dean, Jenna
Hansen, Carmen J.
Westhuyzen, Justin
Waller, Brett
Turnbull, Kirsty
Wood, Maree
Last, Andrew
author_facet Dean, Jenna
Hansen, Carmen J.
Westhuyzen, Justin
Waller, Brett
Turnbull, Kirsty
Wood, Maree
Last, Andrew
author_sort Dean, Jenna
collection PubMed
description INTRODUCTION: Inverse‐planned intensity modulated radiation therapy (IP‐IMRT) has potential benefits over other techniques for tangential intact breast radiotherapy. Possible benefits include increased homogeneity, faster planning time, less inter‐planner variability and lower doses to organs at risk (OAR). We therefore conducted a pilot study of previously treated intact breast patients to compare the current forward‐planned ‘field‐in‐field’ technique (FP‐IMRT) with an IP‐IMRT alternative. METHODS: The IP‐IMRT plans of 20 patients were generated from a template created for the planning system. All patients were prescribed adjuvant whole breast radiotherapy using a hypofractionated regimen of 40.05 Gy in 15 fractions over 3 weeks. Plans were assessed based on visual inspection of coverage as well as statistical analysis and compared to the clinically acceptable FP‐IMRT plans. Patients were planned retrospectively in Monaco 3.2(®) using a laterality‐specific, tangential planning template. Minor adjustments were made as necessary to meet the planning criteria in the protocol. Dose coverage, maximums, homogeneity indices and doses to OAR were recorded. RESULTS: The IP‐IMRT plans provided more consistent coverage (38.18 Gy vs. 36.08 Gy of D95; P = 0.005), a comparable though higher average maximum (D2 = 42.52 Gy vs. 42.08 Gy; P = 0.0001), more homogeneous plans (homogeneity index = 0.908 vs. 0.861; P = 0.01) and somewhat lower V20 heart and lung doses (0.11% vs. 0.89% for heart; 5.4% vs. 7.52% for lung) than FP‐IMRT (P > 0.05). CONCLUSION: Clinically acceptable plans have been generated using the IP‐IMRT templates in Monaco. Improvements in consistency and quality were seen when compared to the FP‐IMRT plans. The template‐based process is an efficient method to inversely plan IMRT for breast patients.
format Online
Article
Text
id pubmed-5167335
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-51673352016-12-28 Tangential intensity modulated radiation therapy (IMRT) to the intact breast Dean, Jenna Hansen, Carmen J. Westhuyzen, Justin Waller, Brett Turnbull, Kirsty Wood, Maree Last, Andrew J Med Radiat Sci Original Articles INTRODUCTION: Inverse‐planned intensity modulated radiation therapy (IP‐IMRT) has potential benefits over other techniques for tangential intact breast radiotherapy. Possible benefits include increased homogeneity, faster planning time, less inter‐planner variability and lower doses to organs at risk (OAR). We therefore conducted a pilot study of previously treated intact breast patients to compare the current forward‐planned ‘field‐in‐field’ technique (FP‐IMRT) with an IP‐IMRT alternative. METHODS: The IP‐IMRT plans of 20 patients were generated from a template created for the planning system. All patients were prescribed adjuvant whole breast radiotherapy using a hypofractionated regimen of 40.05 Gy in 15 fractions over 3 weeks. Plans were assessed based on visual inspection of coverage as well as statistical analysis and compared to the clinically acceptable FP‐IMRT plans. Patients were planned retrospectively in Monaco 3.2(®) using a laterality‐specific, tangential planning template. Minor adjustments were made as necessary to meet the planning criteria in the protocol. Dose coverage, maximums, homogeneity indices and doses to OAR were recorded. RESULTS: The IP‐IMRT plans provided more consistent coverage (38.18 Gy vs. 36.08 Gy of D95; P = 0.005), a comparable though higher average maximum (D2 = 42.52 Gy vs. 42.08 Gy; P = 0.0001), more homogeneous plans (homogeneity index = 0.908 vs. 0.861; P = 0.01) and somewhat lower V20 heart and lung doses (0.11% vs. 0.89% for heart; 5.4% vs. 7.52% for lung) than FP‐IMRT (P > 0.05). CONCLUSION: Clinically acceptable plans have been generated using the IP‐IMRT templates in Monaco. Improvements in consistency and quality were seen when compared to the FP‐IMRT plans. The template‐based process is an efficient method to inversely plan IMRT for breast patients. John Wiley and Sons Inc. 2016-07-18 2016-12 /pmc/articles/PMC5167335/ /pubmed/27741382 http://dx.doi.org/10.1002/jmrs.185 Text en © 2016 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs (http://creativecommons.org/licenses/by-nc-nd/4.0/) License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
spellingShingle Original Articles
Dean, Jenna
Hansen, Carmen J.
Westhuyzen, Justin
Waller, Brett
Turnbull, Kirsty
Wood, Maree
Last, Andrew
Tangential intensity modulated radiation therapy (IMRT) to the intact breast
title Tangential intensity modulated radiation therapy (IMRT) to the intact breast
title_full Tangential intensity modulated radiation therapy (IMRT) to the intact breast
title_fullStr Tangential intensity modulated radiation therapy (IMRT) to the intact breast
title_full_unstemmed Tangential intensity modulated radiation therapy (IMRT) to the intact breast
title_short Tangential intensity modulated radiation therapy (IMRT) to the intact breast
title_sort tangential intensity modulated radiation therapy (imrt) to the intact breast
topic Original Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5167335/
https://www.ncbi.nlm.nih.gov/pubmed/27741382
http://dx.doi.org/10.1002/jmrs.185
work_keys_str_mv AT deanjenna tangentialintensitymodulatedradiationtherapyimrttotheintactbreast
AT hansencarmenj tangentialintensitymodulatedradiationtherapyimrttotheintactbreast
AT westhuyzenjustin tangentialintensitymodulatedradiationtherapyimrttotheintactbreast
AT wallerbrett tangentialintensitymodulatedradiationtherapyimrttotheintactbreast
AT turnbullkirsty tangentialintensitymodulatedradiationtherapyimrttotheintactbreast
AT woodmaree tangentialintensitymodulatedradiationtherapyimrttotheintactbreast
AT lastandrew tangentialintensitymodulatedradiationtherapyimrttotheintactbreast