Cargando…

Diffusion Tensor Imaging for Evaluating Biliary Atresia in Infants and Neonates

BACKGROUND: Preliminary studies have shown that diffusion tensor imaging (DTI) is helpful in evaluating liver disorders. However, there is no published literature on the use of DTI in the diagnosis of biliary atresia (BA). This study aimed to investigate the diagnostic value of the liver average app...

Descripción completa

Detalles Bibliográficos
Autores principales: Liu, Bo, Cai, Jinhua, Zhu, Jin, Zheng, Helin, Zhang, Yun, Wang, Longlun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5167545/
https://www.ncbi.nlm.nih.gov/pubmed/27992499
http://dx.doi.org/10.1371/journal.pone.0168477
_version_ 1782483190404874240
author Liu, Bo
Cai, Jinhua
Zhu, Jin
Zheng, Helin
Zhang, Yun
Wang, Longlun
author_facet Liu, Bo
Cai, Jinhua
Zhu, Jin
Zheng, Helin
Zhang, Yun
Wang, Longlun
author_sort Liu, Bo
collection PubMed
description BACKGROUND: Preliminary studies have shown that diffusion tensor imaging (DTI) is helpful in evaluating liver disorders. However, there is no published literature on the use of DTI in the diagnosis of biliary atresia (BA). This study aimed to investigate the diagnostic value of the liver average apparent diffusion coefficient (ADC) and fractional anisotropy (FA) measured using DTI for BA in neonates and infants. METHODS: Fifty-nine patients with infant jaundice were included in this study. DTI was performed with b factors of 0 and 1000 s/mm(2). Liver fibrosis in the BA group was determined and graded (F0, F1, F2, F3, F4) based on the pathological findings. Statistical analyses were performed to determine the diagnostic accuracy of DTI for BA. RESULTS: The ADC value was significantly lower in the BA group [(1.262±0.127)×10(−3) mm(2)/s] than in the non-BA group [(1.430±0.149)×10(−3) mm(2)/s, (P<0.001)]. The area under the receiver operating characteristic curve was 0.805±0.058 (P<0.001) for ADC. With a cut-off value of 1.317×10(−3) mm(2)/s, ADC achieved a sensitivity of 75% and a specificity of 81.5% for the differential diagnosis of BA and non-BA. In the BA group, the ADC value was significantly correlated with fibrotic stage. Further analysis showed that the ADC value of stage F0 was significantly higher than that of stages F1, F2, F3 and F4, whereas there were no significant differences among stages F1, F2, F3 and F4. CONCLUSION: Hepatic ADC measured with DTI can be used as an adjunct to other noninvasive imaging methods in the differential diagnosis of BA and non-BA. ADC was helpful in detecting liver fibrosis but not in differentiating the fibrotic grades.
format Online
Article
Text
id pubmed-5167545
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-51675452017-01-04 Diffusion Tensor Imaging for Evaluating Biliary Atresia in Infants and Neonates Liu, Bo Cai, Jinhua Zhu, Jin Zheng, Helin Zhang, Yun Wang, Longlun PLoS One Research Article BACKGROUND: Preliminary studies have shown that diffusion tensor imaging (DTI) is helpful in evaluating liver disorders. However, there is no published literature on the use of DTI in the diagnosis of biliary atresia (BA). This study aimed to investigate the diagnostic value of the liver average apparent diffusion coefficient (ADC) and fractional anisotropy (FA) measured using DTI for BA in neonates and infants. METHODS: Fifty-nine patients with infant jaundice were included in this study. DTI was performed with b factors of 0 and 1000 s/mm(2). Liver fibrosis in the BA group was determined and graded (F0, F1, F2, F3, F4) based on the pathological findings. Statistical analyses were performed to determine the diagnostic accuracy of DTI for BA. RESULTS: The ADC value was significantly lower in the BA group [(1.262±0.127)×10(−3) mm(2)/s] than in the non-BA group [(1.430±0.149)×10(−3) mm(2)/s, (P<0.001)]. The area under the receiver operating characteristic curve was 0.805±0.058 (P<0.001) for ADC. With a cut-off value of 1.317×10(−3) mm(2)/s, ADC achieved a sensitivity of 75% and a specificity of 81.5% for the differential diagnosis of BA and non-BA. In the BA group, the ADC value was significantly correlated with fibrotic stage. Further analysis showed that the ADC value of stage F0 was significantly higher than that of stages F1, F2, F3 and F4, whereas there were no significant differences among stages F1, F2, F3 and F4. CONCLUSION: Hepatic ADC measured with DTI can be used as an adjunct to other noninvasive imaging methods in the differential diagnosis of BA and non-BA. ADC was helpful in detecting liver fibrosis but not in differentiating the fibrotic grades. Public Library of Science 2016-12-19 /pmc/articles/PMC5167545/ /pubmed/27992499 http://dx.doi.org/10.1371/journal.pone.0168477 Text en © 2016 Liu et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Liu, Bo
Cai, Jinhua
Zhu, Jin
Zheng, Helin
Zhang, Yun
Wang, Longlun
Diffusion Tensor Imaging for Evaluating Biliary Atresia in Infants and Neonates
title Diffusion Tensor Imaging for Evaluating Biliary Atresia in Infants and Neonates
title_full Diffusion Tensor Imaging for Evaluating Biliary Atresia in Infants and Neonates
title_fullStr Diffusion Tensor Imaging for Evaluating Biliary Atresia in Infants and Neonates
title_full_unstemmed Diffusion Tensor Imaging for Evaluating Biliary Atresia in Infants and Neonates
title_short Diffusion Tensor Imaging for Evaluating Biliary Atresia in Infants and Neonates
title_sort diffusion tensor imaging for evaluating biliary atresia in infants and neonates
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5167545/
https://www.ncbi.nlm.nih.gov/pubmed/27992499
http://dx.doi.org/10.1371/journal.pone.0168477
work_keys_str_mv AT liubo diffusiontensorimagingforevaluatingbiliaryatresiaininfantsandneonates
AT caijinhua diffusiontensorimagingforevaluatingbiliaryatresiaininfantsandneonates
AT zhujin diffusiontensorimagingforevaluatingbiliaryatresiaininfantsandneonates
AT zhenghelin diffusiontensorimagingforevaluatingbiliaryatresiaininfantsandneonates
AT zhangyun diffusiontensorimagingforevaluatingbiliaryatresiaininfantsandneonates
AT wanglonglun diffusiontensorimagingforevaluatingbiliaryatresiaininfantsandneonates