INTRODUCTION: Traditional laparaendoscopic surgery using CO2 pneumoperitoneum is associated with complications and the existing gasless laparaendoscopic surgery has shortcomings such as poor visibility in the operation field. To overcome the disadvantages of the current lifting gasless laparaendosco...

Descripción completa

Detalles Bibliográficos
Autores principales: Hu, Hai, Zhang, Kai, Zhao, Gang, Jiang, Zhaoyan, Huang, Anhua, Cai, Jingli, Xu, Anan, Li, Haidong, He, Chuanqi, Ding, Kan, Lu, Ruiqi, Ye, Ruiqi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5173315/
https://www.ncbi.nlm.nih.gov/pubmed/28018588
http://dx.doi.org/10.1016/j.amsu.2016.11.010
_version_ 1782484302642020352
author Hu, Hai
Zhang, Kai
Zhao, Gang
Jiang, Zhaoyan
Huang, Anhua
Cai, Jingli
Xu, Anan
Li, Haidong
He, Chuanqi
Ding, Kan
Lu, Ruiqi
Ye, Ruiqi
author_facet Hu, Hai
Zhang, Kai
Zhao, Gang
Jiang, Zhaoyan
Huang, Anhua
Cai, Jingli
Xu, Anan
Li, Haidong
He, Chuanqi
Ding, Kan
Lu, Ruiqi
Ye, Ruiqi
author_sort Hu, Hai
collection PubMed
description INTRODUCTION: Traditional laparaendoscopic surgery using CO2 pneumoperitoneum is associated with complications and the existing gasless laparaendoscopic surgery has shortcomings such as poor visibility in the operation field. To overcome the disadvantages of the current lifting gasless laparaendoscopic operation platforms, we developed an inflatable device for gasless laparoscopic operation field formation (LOFF) that can be internally installed and applied in practice. METHODS: We initially designed operation platforms for gasless laparaendoscopic single-port (GLESP) surgery. Subsequently, a triangular prismatic LOFF device was selected and applied successfully to GLESP cholecystectomy of five pigs. Ultimately, using pigs as a model, three surgical approaches (LOFF-assisted laparaendoscopic single-site (LOFF-LESS), LESS surgery, and traditional lifting (GLESP) were compared, and the advantages and drawbacks of inflatable devices for gasless laparoscopic operation field assessed. RESULTS: The use of the LOFF device in GLESP cholecystectomy was first evaluated. The time for surgical space formation (4.4 ± 1.2 and 4.8 ± 1.0), the operating time for gallbladder removal (25.2 ± 4.8 and 25.4 ± 2.7), and the loss of blood (9.4 ± 3.1and 9.2 ± 2.4) was similar between LESS and LOFF, respectively (Table 2). In contrast these parameters were higher in GLESP (6.6 ± 1.0, 30.3 ± 4.4 and 10.1 ± 2.0, respectively. The LOFF-LESS surgery exhibited a clearer exposure of the surgical field and shorter operating time than the GLESP surgery. LESS technology showed less postoperation pain, fast recovery, and extremely high cosmetic satisfaction. CONCLUSION: The LOFF device provides a safe, effective, and feasible operation platform that can be internally installed and inflated for GLESP surgery during cholescytectomy in animal models.
format Online
Article
Text
id pubmed-5173315
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-51733152016-12-23 Experimental use of a novel single-port gasless laparoendoscopic operative field formation device Hu, Hai Zhang, Kai Zhao, Gang Jiang, Zhaoyan Huang, Anhua Cai, Jingli Xu, Anan Li, Haidong He, Chuanqi Ding, Kan Lu, Ruiqi Ye, Ruiqi Ann Med Surg (Lond) Original Research INTRODUCTION: Traditional laparaendoscopic surgery using CO2 pneumoperitoneum is associated with complications and the existing gasless laparaendoscopic surgery has shortcomings such as poor visibility in the operation field. To overcome the disadvantages of the current lifting gasless laparaendoscopic operation platforms, we developed an inflatable device for gasless laparoscopic operation field formation (LOFF) that can be internally installed and applied in practice. METHODS: We initially designed operation platforms for gasless laparaendoscopic single-port (GLESP) surgery. Subsequently, a triangular prismatic LOFF device was selected and applied successfully to GLESP cholecystectomy of five pigs. Ultimately, using pigs as a model, three surgical approaches (LOFF-assisted laparaendoscopic single-site (LOFF-LESS), LESS surgery, and traditional lifting (GLESP) were compared, and the advantages and drawbacks of inflatable devices for gasless laparoscopic operation field assessed. RESULTS: The use of the LOFF device in GLESP cholecystectomy was first evaluated. The time for surgical space formation (4.4 ± 1.2 and 4.8 ± 1.0), the operating time for gallbladder removal (25.2 ± 4.8 and 25.4 ± 2.7), and the loss of blood (9.4 ± 3.1and 9.2 ± 2.4) was similar between LESS and LOFF, respectively (Table 2). In contrast these parameters were higher in GLESP (6.6 ± 1.0, 30.3 ± 4.4 and 10.1 ± 2.0, respectively. The LOFF-LESS surgery exhibited a clearer exposure of the surgical field and shorter operating time than the GLESP surgery. LESS technology showed less postoperation pain, fast recovery, and extremely high cosmetic satisfaction. CONCLUSION: The LOFF device provides a safe, effective, and feasible operation platform that can be internally installed and inflated for GLESP surgery during cholescytectomy in animal models. Elsevier 2016-11-23 /pmc/articles/PMC5173315/ /pubmed/28018588 http://dx.doi.org/10.1016/j.amsu.2016.11.010 Text en © 2016 Published by Elsevier Ltd on behalf of IJS Publishing Group Ltd. http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Hu, Hai
Zhang, Kai
Zhao, Gang
Jiang, Zhaoyan
Huang, Anhua
Cai, Jingli
Xu, Anan
Li, Haidong
He, Chuanqi
Ding, Kan
Lu, Ruiqi
Ye, Ruiqi
Experimental use of a novel single-port gasless laparoendoscopic operative field formation device
title Experimental use of a novel single-port gasless laparoendoscopic operative field formation device
title_full Experimental use of a novel single-port gasless laparoendoscopic operative field formation device
title_fullStr Experimental use of a novel single-port gasless laparoendoscopic operative field formation device
title_full_unstemmed Experimental use of a novel single-port gasless laparoendoscopic operative field formation device
title_short Experimental use of a novel single-port gasless laparoendoscopic operative field formation device
title_sort experimental use of a novel single-port gasless laparoendoscopic operative field formation device
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5173315/
https://www.ncbi.nlm.nih.gov/pubmed/28018588
http://dx.doi.org/10.1016/j.amsu.2016.11.010
work_keys_str_mv AT huhai experimentaluseofanovelsingleportgaslesslaparoendoscopicoperativefieldformationdevice
AT zhangkai experimentaluseofanovelsingleportgaslesslaparoendoscopicoperativefieldformationdevice
AT zhaogang experimentaluseofanovelsingleportgaslesslaparoendoscopicoperativefieldformationdevice
AT jiangzhaoyan experimentaluseofanovelsingleportgaslesslaparoendoscopicoperativefieldformationdevice
AT huanganhua experimentaluseofanovelsingleportgaslesslaparoendoscopicoperativefieldformationdevice
AT caijingli experimentaluseofanovelsingleportgaslesslaparoendoscopicoperativefieldformationdevice
AT xuanan experimentaluseofanovelsingleportgaslesslaparoendoscopicoperativefieldformationdevice
AT lihaidong experimentaluseofanovelsingleportgaslesslaparoendoscopicoperativefieldformationdevice
AT hechuanqi experimentaluseofanovelsingleportgaslesslaparoendoscopicoperativefieldformationdevice
AT dingkan experimentaluseofanovelsingleportgaslesslaparoendoscopicoperativefieldformationdevice
AT luruiqi experimentaluseofanovelsingleportgaslesslaparoendoscopicoperativefieldformationdevice
AT yeruiqi experimentaluseofanovelsingleportgaslesslaparoendoscopicoperativefieldformationdevice