Cargando…

Rapid-Deployment Aortic Valve Replacement after Previous Mechanical Valve Implantation

Recent studies report a reproducible reduction of myocardial ischemic and cardiopulmonary bypass times along with excellent hemodynamics and low rates of paravalvular leakage for rapid-deployment valves. A 68-year-old female patient with aortic stenosis and a mechanical mitral valve which was implan...

Descripción completa

Detalles Bibliográficos
Autores principales: Schlömicher, Markus, Haldenwang, Peter Lukas, Moustafine, Vadim, Wolf, Britta, Zahn, Peter, Bechtel, Matthias, Strauch, Justus Thomas
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2016
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5177430/
https://www.ncbi.nlm.nih.gov/pubmed/28018816
http://dx.doi.org/10.1055/s-0036-1579681
_version_ 1782485013934112768
author Schlömicher, Markus
Haldenwang, Peter Lukas
Moustafine, Vadim
Wolf, Britta
Zahn, Peter
Bechtel, Matthias
Strauch, Justus Thomas
author_facet Schlömicher, Markus
Haldenwang, Peter Lukas
Moustafine, Vadim
Wolf, Britta
Zahn, Peter
Bechtel, Matthias
Strauch, Justus Thomas
author_sort Schlömicher, Markus
collection PubMed
description Recent studies report a reproducible reduction of myocardial ischemic and cardiopulmonary bypass times along with excellent hemodynamics and low rates of paravalvular leakage for rapid-deployment valves. A 68-year-old female patient with aortic stenosis and a mechanical mitral valve which was implanted in 2006 received rapid-deployment aortic valve replacement. The procedure could be performed with a cross-clamp time of 45 minutes and a cardiopulmonary bypass time of 60 minutes. Postoperative course was uncomplicated and the patient was discharged to the referring hospital on postoperative day 8.
format Online
Article
Text
id pubmed-5177430
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-51774302016-12-23 Rapid-Deployment Aortic Valve Replacement after Previous Mechanical Valve Implantation Schlömicher, Markus Haldenwang, Peter Lukas Moustafine, Vadim Wolf, Britta Zahn, Peter Bechtel, Matthias Strauch, Justus Thomas Thorac Cardiovasc Surg Rep Recent studies report a reproducible reduction of myocardial ischemic and cardiopulmonary bypass times along with excellent hemodynamics and low rates of paravalvular leakage for rapid-deployment valves. A 68-year-old female patient with aortic stenosis and a mechanical mitral valve which was implanted in 2006 received rapid-deployment aortic valve replacement. The procedure could be performed with a cross-clamp time of 45 minutes and a cardiopulmonary bypass time of 60 minutes. Postoperative course was uncomplicated and the patient was discharged to the referring hospital on postoperative day 8. Georg Thieme Verlag KG 2016-04-04 2016-12 /pmc/articles/PMC5177430/ /pubmed/28018816 http://dx.doi.org/10.1055/s-0036-1579681 Text en © Thieme Medical Publishers
spellingShingle Schlömicher, Markus
Haldenwang, Peter Lukas
Moustafine, Vadim
Wolf, Britta
Zahn, Peter
Bechtel, Matthias
Strauch, Justus Thomas
Rapid-Deployment Aortic Valve Replacement after Previous Mechanical Valve Implantation
title Rapid-Deployment Aortic Valve Replacement after Previous Mechanical Valve Implantation
title_full Rapid-Deployment Aortic Valve Replacement after Previous Mechanical Valve Implantation
title_fullStr Rapid-Deployment Aortic Valve Replacement after Previous Mechanical Valve Implantation
title_full_unstemmed Rapid-Deployment Aortic Valve Replacement after Previous Mechanical Valve Implantation
title_short Rapid-Deployment Aortic Valve Replacement after Previous Mechanical Valve Implantation
title_sort rapid-deployment aortic valve replacement after previous mechanical valve implantation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5177430/
https://www.ncbi.nlm.nih.gov/pubmed/28018816
http://dx.doi.org/10.1055/s-0036-1579681
work_keys_str_mv AT schlomichermarkus rapiddeploymentaorticvalvereplacementafterpreviousmechanicalvalveimplantation
AT haldenwangpeterlukas rapiddeploymentaorticvalvereplacementafterpreviousmechanicalvalveimplantation
AT moustafinevadim rapiddeploymentaorticvalvereplacementafterpreviousmechanicalvalveimplantation
AT wolfbritta rapiddeploymentaorticvalvereplacementafterpreviousmechanicalvalveimplantation
AT zahnpeter rapiddeploymentaorticvalvereplacementafterpreviousmechanicalvalveimplantation
AT bechtelmatthias rapiddeploymentaorticvalvereplacementafterpreviousmechanicalvalveimplantation
AT strauchjustusthomas rapiddeploymentaorticvalvereplacementafterpreviousmechanicalvalveimplantation