Cargando…

Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation

Background Patients referred to transcatheter aortic valve implantation (TAVI) present with multiple risk factors for intraprocedural complications. Case Description We describe a TAVI procedure with sudden hemodynamic collapse and cardiopulmonary resuscitation. Therefore, extracorporeal membrane ox...

Descripción completa

Detalles Bibliográficos
Autores principales: Kuhn, Elmar W., Madershahian, Navid, Rudolph, Tanja K., Scherner, Maximilian, Choi, Yeong-Hoon, Wahlers, Thorsten
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2016
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5177439/
https://www.ncbi.nlm.nih.gov/pubmed/28018822
http://dx.doi.org/10.1055/s-0036-1572512
_version_ 1782485015938990080
author Kuhn, Elmar W.
Madershahian, Navid
Rudolph, Tanja K.
Scherner, Maximilian
Choi, Yeong-Hoon
Wahlers, Thorsten
author_facet Kuhn, Elmar W.
Madershahian, Navid
Rudolph, Tanja K.
Scherner, Maximilian
Choi, Yeong-Hoon
Wahlers, Thorsten
author_sort Kuhn, Elmar W.
collection PubMed
description Background Patients referred to transcatheter aortic valve implantation (TAVI) present with multiple risk factors for intraprocedural complications. Case Description We describe a TAVI procedure with sudden hemodynamic collapse and cardiopulmonary resuscitation. Therefore, extracorporeal membrane oxygenation cannulas were immediately implanted via vessels of the groin. A Y-connector was inserted into the arterial line of the extracorporeal membrane oxygenator using an additional sheath facilitating to insert a pigtail catheter to guide the further valve implantation. Conclusion This case report provides an option to insert a pigtail catheter after implantation of extracorporeal membrane oxygenator cannulas without need for additional vascular access.
format Online
Article
Text
id pubmed-5177439
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-51774392016-12-23 Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation Kuhn, Elmar W. Madershahian, Navid Rudolph, Tanja K. Scherner, Maximilian Choi, Yeong-Hoon Wahlers, Thorsten Thorac Cardiovasc Surg Rep Background Patients referred to transcatheter aortic valve implantation (TAVI) present with multiple risk factors for intraprocedural complications. Case Description We describe a TAVI procedure with sudden hemodynamic collapse and cardiopulmonary resuscitation. Therefore, extracorporeal membrane oxygenation cannulas were immediately implanted via vessels of the groin. A Y-connector was inserted into the arterial line of the extracorporeal membrane oxygenator using an additional sheath facilitating to insert a pigtail catheter to guide the further valve implantation. Conclusion This case report provides an option to insert a pigtail catheter after implantation of extracorporeal membrane oxygenator cannulas without need for additional vascular access. Georg Thieme Verlag KG 2016-02-24 2016-12 /pmc/articles/PMC5177439/ /pubmed/28018822 http://dx.doi.org/10.1055/s-0036-1572512 Text en © Thieme Medical Publishers
spellingShingle Kuhn, Elmar W.
Madershahian, Navid
Rudolph, Tanja K.
Scherner, Maximilian
Choi, Yeong-Hoon
Wahlers, Thorsten
Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation
title Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation
title_full Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation
title_fullStr Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation
title_full_unstemmed Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation
title_short Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation
title_sort catheter insertion via extracorporeal membrane oxygenation cannula during transcatheter aortic valve implantation
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5177439/
https://www.ncbi.nlm.nih.gov/pubmed/28018822
http://dx.doi.org/10.1055/s-0036-1572512
work_keys_str_mv AT kuhnelmarw catheterinsertionviaextracorporealmembraneoxygenationcannuladuringtranscatheteraorticvalveimplantation
AT madershahiannavid catheterinsertionviaextracorporealmembraneoxygenationcannuladuringtranscatheteraorticvalveimplantation
AT rudolphtanjak catheterinsertionviaextracorporealmembraneoxygenationcannuladuringtranscatheteraorticvalveimplantation
AT schernermaximilian catheterinsertionviaextracorporealmembraneoxygenationcannuladuringtranscatheteraorticvalveimplantation
AT choiyeonghoon catheterinsertionviaextracorporealmembraneoxygenationcannuladuringtranscatheteraorticvalveimplantation
AT wahlersthorsten catheterinsertionviaextracorporealmembraneoxygenationcannuladuringtranscatheteraorticvalveimplantation