Cargando…
Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation
Background Patients referred to transcatheter aortic valve implantation (TAVI) present with multiple risk factors for intraprocedural complications. Case Description We describe a TAVI procedure with sudden hemodynamic collapse and cardiopulmonary resuscitation. Therefore, extracorporeal membrane ox...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Georg Thieme Verlag KG
2016
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5177439/ https://www.ncbi.nlm.nih.gov/pubmed/28018822 http://dx.doi.org/10.1055/s-0036-1572512 |
_version_ | 1782485015938990080 |
---|---|
author | Kuhn, Elmar W. Madershahian, Navid Rudolph, Tanja K. Scherner, Maximilian Choi, Yeong-Hoon Wahlers, Thorsten |
author_facet | Kuhn, Elmar W. Madershahian, Navid Rudolph, Tanja K. Scherner, Maximilian Choi, Yeong-Hoon Wahlers, Thorsten |
author_sort | Kuhn, Elmar W. |
collection | PubMed |
description | Background Patients referred to transcatheter aortic valve implantation (TAVI) present with multiple risk factors for intraprocedural complications. Case Description We describe a TAVI procedure with sudden hemodynamic collapse and cardiopulmonary resuscitation. Therefore, extracorporeal membrane oxygenation cannulas were immediately implanted via vessels of the groin. A Y-connector was inserted into the arterial line of the extracorporeal membrane oxygenator using an additional sheath facilitating to insert a pigtail catheter to guide the further valve implantation. Conclusion This case report provides an option to insert a pigtail catheter after implantation of extracorporeal membrane oxygenator cannulas without need for additional vascular access. |
format | Online Article Text |
id | pubmed-5177439 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-51774392016-12-23 Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation Kuhn, Elmar W. Madershahian, Navid Rudolph, Tanja K. Scherner, Maximilian Choi, Yeong-Hoon Wahlers, Thorsten Thorac Cardiovasc Surg Rep Background Patients referred to transcatheter aortic valve implantation (TAVI) present with multiple risk factors for intraprocedural complications. Case Description We describe a TAVI procedure with sudden hemodynamic collapse and cardiopulmonary resuscitation. Therefore, extracorporeal membrane oxygenation cannulas were immediately implanted via vessels of the groin. A Y-connector was inserted into the arterial line of the extracorporeal membrane oxygenator using an additional sheath facilitating to insert a pigtail catheter to guide the further valve implantation. Conclusion This case report provides an option to insert a pigtail catheter after implantation of extracorporeal membrane oxygenator cannulas without need for additional vascular access. Georg Thieme Verlag KG 2016-02-24 2016-12 /pmc/articles/PMC5177439/ /pubmed/28018822 http://dx.doi.org/10.1055/s-0036-1572512 Text en © Thieme Medical Publishers |
spellingShingle | Kuhn, Elmar W. Madershahian, Navid Rudolph, Tanja K. Scherner, Maximilian Choi, Yeong-Hoon Wahlers, Thorsten Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation |
title | Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation |
title_full | Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation |
title_fullStr | Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation |
title_full_unstemmed | Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation |
title_short | Catheter Insertion via Extracorporeal Membrane Oxygenation Cannula during Transcatheter Aortic Valve Implantation |
title_sort | catheter insertion via extracorporeal membrane oxygenation cannula during transcatheter aortic valve implantation |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5177439/ https://www.ncbi.nlm.nih.gov/pubmed/28018822 http://dx.doi.org/10.1055/s-0036-1572512 |
work_keys_str_mv | AT kuhnelmarw catheterinsertionviaextracorporealmembraneoxygenationcannuladuringtranscatheteraorticvalveimplantation AT madershahiannavid catheterinsertionviaextracorporealmembraneoxygenationcannuladuringtranscatheteraorticvalveimplantation AT rudolphtanjak catheterinsertionviaextracorporealmembraneoxygenationcannuladuringtranscatheteraorticvalveimplantation AT schernermaximilian catheterinsertionviaextracorporealmembraneoxygenationcannuladuringtranscatheteraorticvalveimplantation AT choiyeonghoon catheterinsertionviaextracorporealmembraneoxygenationcannuladuringtranscatheteraorticvalveimplantation AT wahlersthorsten catheterinsertionviaextracorporealmembraneoxygenationcannuladuringtranscatheteraorticvalveimplantation |