Cargando…

Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation

OBJECTIVES: To compare anterior chamber depth (ACD) changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX) and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intra...

Descripción completa

Detalles Bibliográficos
Autores principales: Gür Güngör, Sirel, Akman, Ahmet, Asena, Leyla, Aksoy, Mustafa, Sarıgül Sezenöz, Almila
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5177780/
https://www.ncbi.nlm.nih.gov/pubmed/28050320
http://dx.doi.org/10.4274/tjo.56659
_version_ 1782485051473133568
author Gür Güngör, Sirel
Akman, Ahmet
Asena, Leyla
Aksoy, Mustafa
Sarıgül Sezenöz, Almila
author_facet Gür Güngör, Sirel
Akman, Ahmet
Asena, Leyla
Aksoy, Mustafa
Sarıgül Sezenöz, Almila
author_sort Gür Güngör, Sirel
collection PubMed
description OBJECTIVES: To compare anterior chamber depth (ACD) changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX) and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intraocular lens (IOL) power calculation and postoperative refraction. MATERIALS AND METHODS: Twenty-two eyes of 22 patients with PEX and 30 eyes of 30 normal patients who underwent uneventful phacoemulsification surgery and IOL implantation were included in the study. The ACD of all patients was evaluated preoperatively and at 3 months postoperatively with the ALLEGRO Oculyzer (WaveLight® Oculyzer™ II, Alcon, Novartis)-Scheimpflug imaging system. RESULTS: The postoperative mean ACD values were significantly larger than the preoperative ACD values in both groups (p<0.001 for both groups). The pre- to postoperative change in ACD was 0.46±0.3 mm in the PEX group, which was a larger change than seen in the normal patients (0.12±0.1 mm) (p=0.04). The mean absolute errors (MAE) calculated with different IOL formulas (SRK/T, Haigis, Hoffer and Holladay 1 formulas) were comparable and no statistically significant difference was observed between the two groups (p=0.21). CONCLUSION: Phacoemulsification induces more significant ACD changes in patients with PEX compared to normal patients. However, the MAE did not differ significantly between the groups.
format Online
Article
Text
id pubmed-5177780
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-51777802017-01-03 Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation Gür Güngör, Sirel Akman, Ahmet Asena, Leyla Aksoy, Mustafa Sarıgül Sezenöz, Almila Turk J Ophthalmol Original Article OBJECTIVES: To compare anterior chamber depth (ACD) changes after phacoemulsification surgery in patients with pseudoexfoliation syndrome (PEX) and normal patients using an anterior segment imaging method. Another aim of this study was to evaluate the effect of these changes on the accuracy of intraocular lens (IOL) power calculation and postoperative refraction. MATERIALS AND METHODS: Twenty-two eyes of 22 patients with PEX and 30 eyes of 30 normal patients who underwent uneventful phacoemulsification surgery and IOL implantation were included in the study. The ACD of all patients was evaluated preoperatively and at 3 months postoperatively with the ALLEGRO Oculyzer (WaveLight® Oculyzer™ II, Alcon, Novartis)-Scheimpflug imaging system. RESULTS: The postoperative mean ACD values were significantly larger than the preoperative ACD values in both groups (p<0.001 for both groups). The pre- to postoperative change in ACD was 0.46±0.3 mm in the PEX group, which was a larger change than seen in the normal patients (0.12±0.1 mm) (p=0.04). The mean absolute errors (MAE) calculated with different IOL formulas (SRK/T, Haigis, Hoffer and Holladay 1 formulas) were comparable and no statistically significant difference was observed between the two groups (p=0.21). CONCLUSION: Phacoemulsification induces more significant ACD changes in patients with PEX compared to normal patients. However, the MAE did not differ significantly between the groups. Galenos Publishing 2016-12 2016-12-01 /pmc/articles/PMC5177780/ /pubmed/28050320 http://dx.doi.org/10.4274/tjo.56659 Text en ©Turkish Journal of Ophthalmology, Published by Galenos Publishing. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Gür Güngör, Sirel
Akman, Ahmet
Asena, Leyla
Aksoy, Mustafa
Sarıgül Sezenöz, Almila
Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation
title Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation
title_full Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation
title_fullStr Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation
title_full_unstemmed Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation
title_short Changes in Anterior Chamber Depth after Phacoemulsification in Pseudoexfoliative Eyes and their Effect on Accuracy of Intraocular Lens Power Calculation
title_sort changes in anterior chamber depth after phacoemulsification in pseudoexfoliative eyes and their effect on accuracy of intraocular lens power calculation
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5177780/
https://www.ncbi.nlm.nih.gov/pubmed/28050320
http://dx.doi.org/10.4274/tjo.56659
work_keys_str_mv AT gurgungorsirel changesinanteriorchamberdepthafterphacoemulsificationinpseudoexfoliativeeyesandtheireffectonaccuracyofintraocularlenspowercalculation
AT akmanahmet changesinanteriorchamberdepthafterphacoemulsificationinpseudoexfoliativeeyesandtheireffectonaccuracyofintraocularlenspowercalculation
AT asenaleyla changesinanteriorchamberdepthafterphacoemulsificationinpseudoexfoliativeeyesandtheireffectonaccuracyofintraocularlenspowercalculation
AT aksoymustafa changesinanteriorchamberdepthafterphacoemulsificationinpseudoexfoliativeeyesandtheireffectonaccuracyofintraocularlenspowercalculation
AT sarıgulsezenozalmila changesinanteriorchamberdepthafterphacoemulsificationinpseudoexfoliativeeyesandtheireffectonaccuracyofintraocularlenspowercalculation