Cargando…

Comparison of Anterior Segment Measurements Obtained by Aladdin Optical Biometer and Sirius Corneal Topography

OBJECTIVES: To assess the agreement of anterior segment parameter measurements derived from Aladdin optical biometer using optical low coherence interferometer and Sirius corneal topography using combined Scheimpflug-Placido disk. MATERIALS AND METHODS: Data obtained using the Aladdin and Sirius sys...

Descripción completa

Detalles Bibliográficos
Autores principales: Polat, Onur, Baysal, Zeki, Özcan, Serkan, İnan, Sibel, İnan, Ümit Übeyt
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Galenos Publishing 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5177781/
https://www.ncbi.nlm.nih.gov/pubmed/28050321
http://dx.doi.org/10.4274/tjo.60476
_version_ 1782485051675508736
author Polat, Onur
Baysal, Zeki
Özcan, Serkan
İnan, Sibel
İnan, Ümit Übeyt
author_facet Polat, Onur
Baysal, Zeki
Özcan, Serkan
İnan, Sibel
İnan, Ümit Übeyt
author_sort Polat, Onur
collection PubMed
description OBJECTIVES: To assess the agreement of anterior segment parameter measurements derived from Aladdin optical biometer using optical low coherence interferometer and Sirius corneal topography using combined Scheimpflug-Placido disk. MATERIALS AND METHODS: Data obtained using the Aladdin and Sirius systems from 110 eyes of 59 subjects who had no health problems other than refractive errors were retrospectively evaluated. Anterior chamber depth (ACD), flat (K1) and steep (K2) keratometry readings, and white-to-white distance (WTW) measurements taken with both devices were noted. RESULTS: The mean age of the patients was 47.31±18.57 years (range, 25 to 79 years). Mean ACD was 3.35±0.4 mm using Aladdin and 3.42±0.44 mm using Sirius. Mean difference in ACD was 0.075 mm greater with Sirius than Aladdin (p<0.001). K1 measurement obtained by Aladdin was an average of 0.409 D higher (p<0.001). No statistically significant differences were detected between the two devices in respect to K2 and WTW measurements (p=0.18, p=0.85 respectively). Pearson correlation analysis showed high correlation between the two devices for all measurements (r=0.985, 0.895, 0.961 and 0.766 for ACD, K1, K2 and WTW respectively; p<0.001). CONCLUSION: Anterior segment parameters obtained by Aladdin optical biometer and Sirius anterior segment analysis system correlated well with each other and measurement differences between the devices were clinically negligible except for K1 values.
format Online
Article
Text
id pubmed-5177781
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Galenos Publishing
record_format MEDLINE/PubMed
spelling pubmed-51777812017-01-03 Comparison of Anterior Segment Measurements Obtained by Aladdin Optical Biometer and Sirius Corneal Topography Polat, Onur Baysal, Zeki Özcan, Serkan İnan, Sibel İnan, Ümit Übeyt Turk J Ophthalmol Original Article OBJECTIVES: To assess the agreement of anterior segment parameter measurements derived from Aladdin optical biometer using optical low coherence interferometer and Sirius corneal topography using combined Scheimpflug-Placido disk. MATERIALS AND METHODS: Data obtained using the Aladdin and Sirius systems from 110 eyes of 59 subjects who had no health problems other than refractive errors were retrospectively evaluated. Anterior chamber depth (ACD), flat (K1) and steep (K2) keratometry readings, and white-to-white distance (WTW) measurements taken with both devices were noted. RESULTS: The mean age of the patients was 47.31±18.57 years (range, 25 to 79 years). Mean ACD was 3.35±0.4 mm using Aladdin and 3.42±0.44 mm using Sirius. Mean difference in ACD was 0.075 mm greater with Sirius than Aladdin (p<0.001). K1 measurement obtained by Aladdin was an average of 0.409 D higher (p<0.001). No statistically significant differences were detected between the two devices in respect to K2 and WTW measurements (p=0.18, p=0.85 respectively). Pearson correlation analysis showed high correlation between the two devices for all measurements (r=0.985, 0.895, 0.961 and 0.766 for ACD, K1, K2 and WTW respectively; p<0.001). CONCLUSION: Anterior segment parameters obtained by Aladdin optical biometer and Sirius anterior segment analysis system correlated well with each other and measurement differences between the devices were clinically negligible except for K1 values. Galenos Publishing 2016-12 2016-12-01 /pmc/articles/PMC5177781/ /pubmed/28050321 http://dx.doi.org/10.4274/tjo.60476 Text en ©Turkish Journal of Ophthalmology, Published by Galenos Publishing. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Polat, Onur
Baysal, Zeki
Özcan, Serkan
İnan, Sibel
İnan, Ümit Übeyt
Comparison of Anterior Segment Measurements Obtained by Aladdin Optical Biometer and Sirius Corneal Topography
title Comparison of Anterior Segment Measurements Obtained by Aladdin Optical Biometer and Sirius Corneal Topography
title_full Comparison of Anterior Segment Measurements Obtained by Aladdin Optical Biometer and Sirius Corneal Topography
title_fullStr Comparison of Anterior Segment Measurements Obtained by Aladdin Optical Biometer and Sirius Corneal Topography
title_full_unstemmed Comparison of Anterior Segment Measurements Obtained by Aladdin Optical Biometer and Sirius Corneal Topography
title_short Comparison of Anterior Segment Measurements Obtained by Aladdin Optical Biometer and Sirius Corneal Topography
title_sort comparison of anterior segment measurements obtained by aladdin optical biometer and sirius corneal topography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5177781/
https://www.ncbi.nlm.nih.gov/pubmed/28050321
http://dx.doi.org/10.4274/tjo.60476
work_keys_str_mv AT polatonur comparisonofanteriorsegmentmeasurementsobtainedbyaladdinopticalbiometerandsiriuscornealtopography
AT baysalzeki comparisonofanteriorsegmentmeasurementsobtainedbyaladdinopticalbiometerandsiriuscornealtopography
AT ozcanserkan comparisonofanteriorsegmentmeasurementsobtainedbyaladdinopticalbiometerandsiriuscornealtopography
AT inansibel comparisonofanteriorsegmentmeasurementsobtainedbyaladdinopticalbiometerandsiriuscornealtopography
AT inanumitubeyt comparisonofanteriorsegmentmeasurementsobtainedbyaladdinopticalbiometerandsiriuscornealtopography