Cargando…

Impact of high-sensitivity cardiac troponin on use of coronary angiography, cardiac stress testing, and time to discharge in suspected acute myocardial infarction

AIMS: High-sensitivity cardiac troponin (hs-cTn) assays provide higher diagnostic accuracy for acute myocardial infarction (AMI) when compared with conventional assays, but may result in increased use of unnecessary coronary angiographies due to their increased detection of cardiomyocyte injury in c...

Descripción completa

Detalles Bibliográficos
Autores principales: Twerenbold, Raphael, Jaeger, Cedric, Rubini Gimenez, Maria, Wildi, Karin, Reichlin, Tobias, Nestelberger, Thomas, Boeddinghaus, Jasper, Grimm, Karin, Puelacher, Christian, Moehring, Berit, Pretre, Gil, Schaerli, Nicolas, Campodarve, Isabel, Rentsch, Katharina, Steuer, Stephan, Osswald, Stefan, Mueller, Christian
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5177796/
https://www.ncbi.nlm.nih.gov/pubmed/27357358
http://dx.doi.org/10.1093/eurheartj/ehw232
_version_ 1782485054102962176
author Twerenbold, Raphael
Jaeger, Cedric
Rubini Gimenez, Maria
Wildi, Karin
Reichlin, Tobias
Nestelberger, Thomas
Boeddinghaus, Jasper
Grimm, Karin
Puelacher, Christian
Moehring, Berit
Pretre, Gil
Schaerli, Nicolas
Campodarve, Isabel
Rentsch, Katharina
Steuer, Stephan
Osswald, Stefan
Mueller, Christian
author_facet Twerenbold, Raphael
Jaeger, Cedric
Rubini Gimenez, Maria
Wildi, Karin
Reichlin, Tobias
Nestelberger, Thomas
Boeddinghaus, Jasper
Grimm, Karin
Puelacher, Christian
Moehring, Berit
Pretre, Gil
Schaerli, Nicolas
Campodarve, Isabel
Rentsch, Katharina
Steuer, Stephan
Osswald, Stefan
Mueller, Christian
author_sort Twerenbold, Raphael
collection PubMed
description AIMS: High-sensitivity cardiac troponin (hs-cTn) assays provide higher diagnostic accuracy for acute myocardial infarction (AMI) when compared with conventional assays, but may result in increased use of unnecessary coronary angiographies due to their increased detection of cardiomyocyte injury in conditions other than AMI. METHODS AND RESULTS: We evaluated the impact of the clinical introduction of high-sensitivity cardiac troponin T (hs-cTnT) on the use of coronary angiography, stress testing, and time to discharge in 2544 patients presenting with symptoms suggestive of AMI to the emergency department (ED) within a multicentre study either before (1455 patients) or after (1089 patients) hs-cTnT introduction. Acute myocardial infarction was more often the clinical discharge diagnosis after hs-cTnT introduction (10 vs. 14%, P < 0.001), while unstable angina less often the clinical discharge diagnosis (14 vs. 9%, P = 0.007). The rate of coronary angiography was similar before and after the introduction of hs-cTnT (23 vs. 23%, P = 0.092), as was the percentage of coronary angiographies showing no stenosis (11 vs. 7%, P = 0.361). In contrast, the use of stress testing was substantially reduced from 29 to 19% (P < 0.001). In outpatients, median time to discharge from the ED decreased by 79 min (P < 0.001). Mean total costs decreased by 20% in outpatients after the introduction of hs-cTnT (P = 0.002). CONCLUSION: The clinical introduction of hs-cTn does not lead to an increased or inappropriate use of coronary angiography. Introduction of hs-cTn is associated with an improved rule-out process and thereby reduces the need for stress testing and time to discharge. CLINICAL TRIAL REGISTRATION INFORMATION: www.clinicaltrials.gov. Identifier, NCT00470587.
format Online
Article
Text
id pubmed-5177796
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-51777962016-12-23 Impact of high-sensitivity cardiac troponin on use of coronary angiography, cardiac stress testing, and time to discharge in suspected acute myocardial infarction Twerenbold, Raphael Jaeger, Cedric Rubini Gimenez, Maria Wildi, Karin Reichlin, Tobias Nestelberger, Thomas Boeddinghaus, Jasper Grimm, Karin Puelacher, Christian Moehring, Berit Pretre, Gil Schaerli, Nicolas Campodarve, Isabel Rentsch, Katharina Steuer, Stephan Osswald, Stefan Mueller, Christian Eur Heart J Clinical Research AIMS: High-sensitivity cardiac troponin (hs-cTn) assays provide higher diagnostic accuracy for acute myocardial infarction (AMI) when compared with conventional assays, but may result in increased use of unnecessary coronary angiographies due to their increased detection of cardiomyocyte injury in conditions other than AMI. METHODS AND RESULTS: We evaluated the impact of the clinical introduction of high-sensitivity cardiac troponin T (hs-cTnT) on the use of coronary angiography, stress testing, and time to discharge in 2544 patients presenting with symptoms suggestive of AMI to the emergency department (ED) within a multicentre study either before (1455 patients) or after (1089 patients) hs-cTnT introduction. Acute myocardial infarction was more often the clinical discharge diagnosis after hs-cTnT introduction (10 vs. 14%, P < 0.001), while unstable angina less often the clinical discharge diagnosis (14 vs. 9%, P = 0.007). The rate of coronary angiography was similar before and after the introduction of hs-cTnT (23 vs. 23%, P = 0.092), as was the percentage of coronary angiographies showing no stenosis (11 vs. 7%, P = 0.361). In contrast, the use of stress testing was substantially reduced from 29 to 19% (P < 0.001). In outpatients, median time to discharge from the ED decreased by 79 min (P < 0.001). Mean total costs decreased by 20% in outpatients after the introduction of hs-cTnT (P = 0.002). CONCLUSION: The clinical introduction of hs-cTn does not lead to an increased or inappropriate use of coronary angiography. Introduction of hs-cTn is associated with an improved rule-out process and thereby reduces the need for stress testing and time to discharge. CLINICAL TRIAL REGISTRATION INFORMATION: www.clinicaltrials.gov. Identifier, NCT00470587. Oxford University Press 2016-11-21 2016-06-29 /pmc/articles/PMC5177796/ /pubmed/27357358 http://dx.doi.org/10.1093/eurheartj/ehw232 Text en © The Author 2016. Published by Oxford University Press on behalf of the European Society of Cardiology. http://creativecommons.org/licenses/by-nc/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Clinical Research
Twerenbold, Raphael
Jaeger, Cedric
Rubini Gimenez, Maria
Wildi, Karin
Reichlin, Tobias
Nestelberger, Thomas
Boeddinghaus, Jasper
Grimm, Karin
Puelacher, Christian
Moehring, Berit
Pretre, Gil
Schaerli, Nicolas
Campodarve, Isabel
Rentsch, Katharina
Steuer, Stephan
Osswald, Stefan
Mueller, Christian
Impact of high-sensitivity cardiac troponin on use of coronary angiography, cardiac stress testing, and time to discharge in suspected acute myocardial infarction
title Impact of high-sensitivity cardiac troponin on use of coronary angiography, cardiac stress testing, and time to discharge in suspected acute myocardial infarction
title_full Impact of high-sensitivity cardiac troponin on use of coronary angiography, cardiac stress testing, and time to discharge in suspected acute myocardial infarction
title_fullStr Impact of high-sensitivity cardiac troponin on use of coronary angiography, cardiac stress testing, and time to discharge in suspected acute myocardial infarction
title_full_unstemmed Impact of high-sensitivity cardiac troponin on use of coronary angiography, cardiac stress testing, and time to discharge in suspected acute myocardial infarction
title_short Impact of high-sensitivity cardiac troponin on use of coronary angiography, cardiac stress testing, and time to discharge in suspected acute myocardial infarction
title_sort impact of high-sensitivity cardiac troponin on use of coronary angiography, cardiac stress testing, and time to discharge in suspected acute myocardial infarction
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5177796/
https://www.ncbi.nlm.nih.gov/pubmed/27357358
http://dx.doi.org/10.1093/eurheartj/ehw232
work_keys_str_mv AT twerenboldraphael impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT jaegercedric impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT rubinigimenezmaria impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT wildikarin impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT reichlintobias impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT nestelbergerthomas impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT boeddinghausjasper impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT grimmkarin impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT puelacherchristian impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT moehringberit impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT pretregil impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT schaerlinicolas impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT campodarveisabel impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT rentschkatharina impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT steuerstephan impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT osswaldstefan impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction
AT muellerchristian impactofhighsensitivitycardiactroponinonuseofcoronaryangiographycardiacstresstestingandtimetodischargeinsuspectedacutemyocardialinfarction