Phase Meter Calibration at NBS

To provide a phase meter calibration service, a phase angle calibration standard has been developed at NBS. This standard is a signal generator with two sinusoidal outputs and uses direct digital synthesis to generate the signals. The phase angle between the two sinusoids is determined by the input...

Descripción completa

Detalles Bibliográficos
Autor principal: Turgel, Raymond S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1988
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5178310/
http://dx.doi.org/10.6028/jres.093.006
_version_ 1782485154672934912
author Turgel, Raymond S.
author_facet Turgel, Raymond S.
author_sort Turgel, Raymond S.
collection PubMed
description To provide a phase meter calibration service, a phase angle calibration standard has been developed at NBS. This standard is a signal generator with two sinusoidal outputs and uses direct digital synthesis to generate the signals. The phase angle between the two sinusoids is determined by the input parameters in the calculation of the sets of digital values from which the analog output is synthesized. An auto-zero compensation mode corrects for residual phase differences in the two output channels. The phase resolution is better than 0.002° over a frequency range from 2 Hz to 5 kHz and 0.005° from 5 to 50 kHz. Phase meter calibration data are fitted to a linear model from which appropriate corrections for the phase meter readings can be derived. Statistical treatment of the data provides an estimate of the uncertainty of the corrected phase meter readings relative to the phase angle calibration standard.
format Online
Article
Text
id pubmed-5178310
institution National Center for Biotechnology Information
language English
publishDate 1988
publisher [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
record_format MEDLINE/PubMed
spelling pubmed-51783102021-08-02 Phase Meter Calibration at NBS Turgel, Raymond S. J Res Natl Bur Stand (1977) Article To provide a phase meter calibration service, a phase angle calibration standard has been developed at NBS. This standard is a signal generator with two sinusoidal outputs and uses direct digital synthesis to generate the signals. The phase angle between the two sinusoids is determined by the input parameters in the calculation of the sets of digital values from which the analog output is synthesized. An auto-zero compensation mode corrects for residual phase differences in the two output channels. The phase resolution is better than 0.002° over a frequency range from 2 Hz to 5 kHz and 0.005° from 5 to 50 kHz. Phase meter calibration data are fitted to a linear model from which appropriate corrections for the phase meter readings can be derived. Statistical treatment of the data provides an estimate of the uncertainty of the corrected phase meter readings relative to the phase angle calibration standard. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1988 1988-02-01 /pmc/articles/PMC5178310/ http://dx.doi.org/10.6028/jres.093.006 Text en https://creativecommons.org/publicdomain/zero/1.0/ The Journal of Research of the National Bureau of Standards is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright.
spellingShingle Article
Turgel, Raymond S.
Phase Meter Calibration at NBS
title Phase Meter Calibration at NBS
title_full Phase Meter Calibration at NBS
title_fullStr Phase Meter Calibration at NBS
title_full_unstemmed Phase Meter Calibration at NBS
title_short Phase Meter Calibration at NBS
title_sort phase meter calibration at nbs
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5178310/
http://dx.doi.org/10.6028/jres.093.006
work_keys_str_mv AT turgelraymonds phasemetercalibrationatnbs