Cargando…

Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function?

High quality means good fitness for the intended use. Research activity regarding quality measures for platelet transfusions has focused on platelet storage and platelet storage lesion. Thus, platelet quality is judged from the manufacturer's point of view and regulated to ensure consistency an...

Descripción completa

Detalles Bibliográficos
Autores principales: Maurer-Spurej, Elisabeth, Chipperfield, Kate
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5178367/
https://www.ncbi.nlm.nih.gov/pubmed/28053805
http://dx.doi.org/10.1155/2016/6140239
_version_ 1782485167314567168
author Maurer-Spurej, Elisabeth
Chipperfield, Kate
author_facet Maurer-Spurej, Elisabeth
Chipperfield, Kate
author_sort Maurer-Spurej, Elisabeth
collection PubMed
description High quality means good fitness for the intended use. Research activity regarding quality measures for platelet transfusions has focused on platelet storage and platelet storage lesion. Thus, platelet quality is judged from the manufacturer's point of view and regulated to ensure consistency and stability of the manufacturing process. Assuming that fresh product is always superior to aged product, maintaining in vitro characteristics should preserve high quality. However, despite the highest in vitro quality standards, platelets often fail in vivo. This suggests we may need different quality measures to predict platelet performance after transfusion. Adding to this complexity, platelets are used clinically for very different purposes: platelets need to circulate when given as prophylaxis to cancer patients and to stop bleeding when given to surgery or trauma patients. In addition, the emerging application of platelet-rich plasma injections exploits the immunological functions of platelets. Requirements for quality of platelets intended to prevent bleeding, stop bleeding, or promote wound healing are potentially very different. Can a single measurable characteristic describe platelet quality for all uses? Here we present microparticle measurement in platelet samples, and its potential to become the universal quality characteristic for platelet production, storage, viability, function, and compatibility.
format Online
Article
Text
id pubmed-5178367
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-51783672017-01-04 Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function? Maurer-Spurej, Elisabeth Chipperfield, Kate J Blood Transfus Review Article High quality means good fitness for the intended use. Research activity regarding quality measures for platelet transfusions has focused on platelet storage and platelet storage lesion. Thus, platelet quality is judged from the manufacturer's point of view and regulated to ensure consistency and stability of the manufacturing process. Assuming that fresh product is always superior to aged product, maintaining in vitro characteristics should preserve high quality. However, despite the highest in vitro quality standards, platelets often fail in vivo. This suggests we may need different quality measures to predict platelet performance after transfusion. Adding to this complexity, platelets are used clinically for very different purposes: platelets need to circulate when given as prophylaxis to cancer patients and to stop bleeding when given to surgery or trauma patients. In addition, the emerging application of platelet-rich plasma injections exploits the immunological functions of platelets. Requirements for quality of platelets intended to prevent bleeding, stop bleeding, or promote wound healing are potentially very different. Can a single measurable characteristic describe platelet quality for all uses? Here we present microparticle measurement in platelet samples, and its potential to become the universal quality characteristic for platelet production, storage, viability, function, and compatibility. Hindawi Publishing Corporation 2016 2016-12-08 /pmc/articles/PMC5178367/ /pubmed/28053805 http://dx.doi.org/10.1155/2016/6140239 Text en Copyright © 2016 E. Maurer-Spurej and K. Chipperfield. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Maurer-Spurej, Elisabeth
Chipperfield, Kate
Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function?
title Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function?
title_full Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function?
title_fullStr Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function?
title_full_unstemmed Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function?
title_short Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function?
title_sort could microparticles be the universal quality indicator for platelet viability and function?
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5178367/
https://www.ncbi.nlm.nih.gov/pubmed/28053805
http://dx.doi.org/10.1155/2016/6140239
work_keys_str_mv AT maurerspurejelisabeth couldmicroparticlesbetheuniversalqualityindicatorforplateletviabilityandfunction
AT chipperfieldkate couldmicroparticlesbetheuniversalqualityindicatorforplateletviabilityandfunction