Cargando…
Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function?
High quality means good fitness for the intended use. Research activity regarding quality measures for platelet transfusions has focused on platelet storage and platelet storage lesion. Thus, platelet quality is judged from the manufacturer's point of view and regulated to ensure consistency an...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5178367/ https://www.ncbi.nlm.nih.gov/pubmed/28053805 http://dx.doi.org/10.1155/2016/6140239 |
_version_ | 1782485167314567168 |
---|---|
author | Maurer-Spurej, Elisabeth Chipperfield, Kate |
author_facet | Maurer-Spurej, Elisabeth Chipperfield, Kate |
author_sort | Maurer-Spurej, Elisabeth |
collection | PubMed |
description | High quality means good fitness for the intended use. Research activity regarding quality measures for platelet transfusions has focused on platelet storage and platelet storage lesion. Thus, platelet quality is judged from the manufacturer's point of view and regulated to ensure consistency and stability of the manufacturing process. Assuming that fresh product is always superior to aged product, maintaining in vitro characteristics should preserve high quality. However, despite the highest in vitro quality standards, platelets often fail in vivo. This suggests we may need different quality measures to predict platelet performance after transfusion. Adding to this complexity, platelets are used clinically for very different purposes: platelets need to circulate when given as prophylaxis to cancer patients and to stop bleeding when given to surgery or trauma patients. In addition, the emerging application of platelet-rich plasma injections exploits the immunological functions of platelets. Requirements for quality of platelets intended to prevent bleeding, stop bleeding, or promote wound healing are potentially very different. Can a single measurable characteristic describe platelet quality for all uses? Here we present microparticle measurement in platelet samples, and its potential to become the universal quality characteristic for platelet production, storage, viability, function, and compatibility. |
format | Online Article Text |
id | pubmed-5178367 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-51783672017-01-04 Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function? Maurer-Spurej, Elisabeth Chipperfield, Kate J Blood Transfus Review Article High quality means good fitness for the intended use. Research activity regarding quality measures for platelet transfusions has focused on platelet storage and platelet storage lesion. Thus, platelet quality is judged from the manufacturer's point of view and regulated to ensure consistency and stability of the manufacturing process. Assuming that fresh product is always superior to aged product, maintaining in vitro characteristics should preserve high quality. However, despite the highest in vitro quality standards, platelets often fail in vivo. This suggests we may need different quality measures to predict platelet performance after transfusion. Adding to this complexity, platelets are used clinically for very different purposes: platelets need to circulate when given as prophylaxis to cancer patients and to stop bleeding when given to surgery or trauma patients. In addition, the emerging application of platelet-rich plasma injections exploits the immunological functions of platelets. Requirements for quality of platelets intended to prevent bleeding, stop bleeding, or promote wound healing are potentially very different. Can a single measurable characteristic describe platelet quality for all uses? Here we present microparticle measurement in platelet samples, and its potential to become the universal quality characteristic for platelet production, storage, viability, function, and compatibility. Hindawi Publishing Corporation 2016 2016-12-08 /pmc/articles/PMC5178367/ /pubmed/28053805 http://dx.doi.org/10.1155/2016/6140239 Text en Copyright © 2016 E. Maurer-Spurej and K. Chipperfield. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Maurer-Spurej, Elisabeth Chipperfield, Kate Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function? |
title | Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function? |
title_full | Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function? |
title_fullStr | Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function? |
title_full_unstemmed | Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function? |
title_short | Could Microparticles Be the Universal Quality Indicator for Platelet Viability and Function? |
title_sort | could microparticles be the universal quality indicator for platelet viability and function? |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5178367/ https://www.ncbi.nlm.nih.gov/pubmed/28053805 http://dx.doi.org/10.1155/2016/6140239 |
work_keys_str_mv | AT maurerspurejelisabeth couldmicroparticlesbetheuniversalqualityindicatorforplateletviabilityandfunction AT chipperfieldkate couldmicroparticlesbetheuniversalqualityindicatorforplateletviabilityandfunction |