Cargando…
P13, the EMBL macromolecular crystallography beamline at the low-emittance PETRA III ring for high- and low-energy phasing with variable beam focusing
The macromolecular crystallography P13 beamline is part of the European Molecular Biology Laboratory Integrated Facility for Structural Biology at PETRA III (DESY, Hamburg, Germany) and has been in user operation since mid-2013. P13 is tunable across the energy range from 4 to 17.5 keV to support cr...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5182027/ https://www.ncbi.nlm.nih.gov/pubmed/28009574 http://dx.doi.org/10.1107/S1600577516016465 |
_version_ | 1782485814303784960 |
---|---|
author | Cianci, Michele Bourenkov, Gleb Pompidor, Guillaume Karpics, Ivars Kallio, Johanna Bento, Isabel Roessle, Manfred Cipriani, Florent Fiedler, Stefan Schneider, Thomas R. |
author_facet | Cianci, Michele Bourenkov, Gleb Pompidor, Guillaume Karpics, Ivars Kallio, Johanna Bento, Isabel Roessle, Manfred Cipriani, Florent Fiedler, Stefan Schneider, Thomas R. |
author_sort | Cianci, Michele |
collection | PubMed |
description | The macromolecular crystallography P13 beamline is part of the European Molecular Biology Laboratory Integrated Facility for Structural Biology at PETRA III (DESY, Hamburg, Germany) and has been in user operation since mid-2013. P13 is tunable across the energy range from 4 to 17.5 keV to support crystallographic data acquisition exploiting a wide range of elemental absorption edges for experimental phase determination. An adaptive Kirkpatrick–Baez focusing system provides an X-ray beam with a high photon flux and tunable focus size to adapt to diverse experimental situations. Data collections at energies as low as 4 keV (λ = 3.1 Å) are possible due to a beamline design minimizing background and maximizing photon flux particularly at low energy (up to 10(11) photons s(−1) at 4 keV), a custom calibration of the PILATUS 6M-F detector for use at low energies, and the availability of a helium path. At high energies, the high photon flux (5.4 × 10(11) photons s(−1) at 17.5 keV) combined with a large area detector mounted on a 2θ arm allows data collection to sub-atomic resolution (0.55 Å). A peak flux of about 8.0 × 10(12) photons s(−1) is reached at 11 keV. Automated sample mounting is available by means of the robotic sample changer ‘MARVIN’ with a dewar capacity of 160 samples. In close proximity to the beamline, laboratories have been set up for sample preparation and characterization; a laboratory specifically equipped for on-site heavy atom derivatization with a library of more than 150 compounds is available to beamline users. |
format | Online Article Text |
id | pubmed-5182027 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-51820272017-01-10 P13, the EMBL macromolecular crystallography beamline at the low-emittance PETRA III ring for high- and low-energy phasing with variable beam focusing Cianci, Michele Bourenkov, Gleb Pompidor, Guillaume Karpics, Ivars Kallio, Johanna Bento, Isabel Roessle, Manfred Cipriani, Florent Fiedler, Stefan Schneider, Thomas R. J Synchrotron Radiat Beamlines The macromolecular crystallography P13 beamline is part of the European Molecular Biology Laboratory Integrated Facility for Structural Biology at PETRA III (DESY, Hamburg, Germany) and has been in user operation since mid-2013. P13 is tunable across the energy range from 4 to 17.5 keV to support crystallographic data acquisition exploiting a wide range of elemental absorption edges for experimental phase determination. An adaptive Kirkpatrick–Baez focusing system provides an X-ray beam with a high photon flux and tunable focus size to adapt to diverse experimental situations. Data collections at energies as low as 4 keV (λ = 3.1 Å) are possible due to a beamline design minimizing background and maximizing photon flux particularly at low energy (up to 10(11) photons s(−1) at 4 keV), a custom calibration of the PILATUS 6M-F detector for use at low energies, and the availability of a helium path. At high energies, the high photon flux (5.4 × 10(11) photons s(−1) at 17.5 keV) combined with a large area detector mounted on a 2θ arm allows data collection to sub-atomic resolution (0.55 Å). A peak flux of about 8.0 × 10(12) photons s(−1) is reached at 11 keV. Automated sample mounting is available by means of the robotic sample changer ‘MARVIN’ with a dewar capacity of 160 samples. In close proximity to the beamline, laboratories have been set up for sample preparation and characterization; a laboratory specifically equipped for on-site heavy atom derivatization with a library of more than 150 compounds is available to beamline users. International Union of Crystallography 2017-01-01 /pmc/articles/PMC5182027/ /pubmed/28009574 http://dx.doi.org/10.1107/S1600577516016465 Text en © Michele Cianci et al. 2017 http://creativecommons.org/licenses/by/2.0/uk/ This is an open-access article distributed under the terms of the Creative Commons Attribution Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited. |
spellingShingle | Beamlines Cianci, Michele Bourenkov, Gleb Pompidor, Guillaume Karpics, Ivars Kallio, Johanna Bento, Isabel Roessle, Manfred Cipriani, Florent Fiedler, Stefan Schneider, Thomas R. P13, the EMBL macromolecular crystallography beamline at the low-emittance PETRA III ring for high- and low-energy phasing with variable beam focusing |
title | P13, the EMBL macromolecular crystallography beamline at the low-emittance PETRA III ring for high- and low-energy phasing with variable beam focusing |
title_full | P13, the EMBL macromolecular crystallography beamline at the low-emittance PETRA III ring for high- and low-energy phasing with variable beam focusing |
title_fullStr | P13, the EMBL macromolecular crystallography beamline at the low-emittance PETRA III ring for high- and low-energy phasing with variable beam focusing |
title_full_unstemmed | P13, the EMBL macromolecular crystallography beamline at the low-emittance PETRA III ring for high- and low-energy phasing with variable beam focusing |
title_short | P13, the EMBL macromolecular crystallography beamline at the low-emittance PETRA III ring for high- and low-energy phasing with variable beam focusing |
title_sort | p13, the embl macromolecular crystallography beamline at the low-emittance petra iii ring for high- and low-energy phasing with variable beam focusing |
topic | Beamlines |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5182027/ https://www.ncbi.nlm.nih.gov/pubmed/28009574 http://dx.doi.org/10.1107/S1600577516016465 |
work_keys_str_mv | AT ciancimichele p13theemblmacromolecularcrystallographybeamlineatthelowemittancepetraiiiringforhighandlowenergyphasingwithvariablebeamfocusing AT bourenkovgleb p13theemblmacromolecularcrystallographybeamlineatthelowemittancepetraiiiringforhighandlowenergyphasingwithvariablebeamfocusing AT pompidorguillaume p13theemblmacromolecularcrystallographybeamlineatthelowemittancepetraiiiringforhighandlowenergyphasingwithvariablebeamfocusing AT karpicsivars p13theemblmacromolecularcrystallographybeamlineatthelowemittancepetraiiiringforhighandlowenergyphasingwithvariablebeamfocusing AT kalliojohanna p13theemblmacromolecularcrystallographybeamlineatthelowemittancepetraiiiringforhighandlowenergyphasingwithvariablebeamfocusing AT bentoisabel p13theemblmacromolecularcrystallographybeamlineatthelowemittancepetraiiiringforhighandlowenergyphasingwithvariablebeamfocusing AT roesslemanfred p13theemblmacromolecularcrystallographybeamlineatthelowemittancepetraiiiringforhighandlowenergyphasingwithvariablebeamfocusing AT ciprianiflorent p13theemblmacromolecularcrystallographybeamlineatthelowemittancepetraiiiringforhighandlowenergyphasingwithvariablebeamfocusing AT fiedlerstefan p13theemblmacromolecularcrystallographybeamlineatthelowemittancepetraiiiringforhighandlowenergyphasingwithvariablebeamfocusing AT schneiderthomasr p13theemblmacromolecularcrystallographybeamlineatthelowemittancepetraiiiringforhighandlowenergyphasingwithvariablebeamfocusing |