Cargando…

2D to 3D Evaluation of Organs at Risk Doses in Intracavitary Brachytherapy for Cervical Cancer

PURPOSE: To compare International Commission on Radiation Units and Measurements (ICRU) bladder and rectum reference points doses with volumetric doses in 3D intracavitary brachytherapy (ICBT) for cervical cancer. Also to compare bladder, rectum and sigmoid (organs at risk, OARs) volume doses with d...

Descripción completa

Detalles Bibliográficos
Autores principales: Tan, Yun Inn, Choo, Bok Ai, Lee, Khai Mun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2010
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5183646/
https://www.ncbi.nlm.nih.gov/pubmed/28031742
http://dx.doi.org/10.5114/jcb.2010.13721
_version_ 1782486089157574656
author Tan, Yun Inn
Choo, Bok Ai
Lee, Khai Mun
author_facet Tan, Yun Inn
Choo, Bok Ai
Lee, Khai Mun
author_sort Tan, Yun Inn
collection PubMed
description PURPOSE: To compare International Commission on Radiation Units and Measurements (ICRU) bladder and rectum reference points doses with volumetric doses in 3D intracavitary brachytherapy (ICBT) for cervical cancer. Also to compare bladder, rectum and sigmoid (organs at risk, OARs) volume doses with dose constraints recommended by the (GYN) GEC-ESTRO Working Group. MATERIAL AND METHODS: A retrospective study was carried out on 10 patients with a total of 55 fractions CT-based high dose rate (HDR) ICBT. ICRU bladder (bICRU) and rectum (rICRU) points were defined according to ICRU Report 38 on the CT images and prospectively kept to less than 80% of prescription dose to Point A during real treatment planning. Post-treatment, outer wall of OARs were contoured and minimum dose to 2cc (D2cc) of the most irradiated part of the OARs was obtained from the dose-volume histogram (DVH). Total dose (external beam radiotherapy plus ICBT) were computed with ICRU point dose and D2cc and compared. RESULTS: The mean ICRU point dose and D2cc volume dose were found to be significantly different for bladder (per fraction: p = 0.000; total dose: p = 0.004) but no differences were found for rectum (per fraction: p = 0.055; total dose: p = 0.090). bICRU point dose underestimated D2cc dose with an average ratio of 1.34 ± 0.34. 3 out of 10 patients, 7 out of 10 patients, and 5 out of 10 patients exceeded the recommended dose constraint for bladder, rectum, and sigmoid, respectively. CONCLUSIONS: bICRU was not representative of bladder D2cc and resulted in different total dose. rICRU was found to be similar to D2cc dose and was reliable in total dose computation. Our current institutional practice of point-based planning in ICBT resulted in significant number of patients’ OARs doses exceeded the volume constraint, because the total dose concept was not used propectively in planning.
format Online
Article
Text
id pubmed-5183646
institution National Center for Biotechnology Information
language English
publishDate 2010
publisher Termedia Publishing House
record_format MEDLINE/PubMed
spelling pubmed-51836462016-12-28 2D to 3D Evaluation of Organs at Risk Doses in Intracavitary Brachytherapy for Cervical Cancer Tan, Yun Inn Choo, Bok Ai Lee, Khai Mun J Contemp Brachytherapy Original Article PURPOSE: To compare International Commission on Radiation Units and Measurements (ICRU) bladder and rectum reference points doses with volumetric doses in 3D intracavitary brachytherapy (ICBT) for cervical cancer. Also to compare bladder, rectum and sigmoid (organs at risk, OARs) volume doses with dose constraints recommended by the (GYN) GEC-ESTRO Working Group. MATERIAL AND METHODS: A retrospective study was carried out on 10 patients with a total of 55 fractions CT-based high dose rate (HDR) ICBT. ICRU bladder (bICRU) and rectum (rICRU) points were defined according to ICRU Report 38 on the CT images and prospectively kept to less than 80% of prescription dose to Point A during real treatment planning. Post-treatment, outer wall of OARs were contoured and minimum dose to 2cc (D2cc) of the most irradiated part of the OARs was obtained from the dose-volume histogram (DVH). Total dose (external beam radiotherapy plus ICBT) were computed with ICRU point dose and D2cc and compared. RESULTS: The mean ICRU point dose and D2cc volume dose were found to be significantly different for bladder (per fraction: p = 0.000; total dose: p = 0.004) but no differences were found for rectum (per fraction: p = 0.055; total dose: p = 0.090). bICRU point dose underestimated D2cc dose with an average ratio of 1.34 ± 0.34. 3 out of 10 patients, 7 out of 10 patients, and 5 out of 10 patients exceeded the recommended dose constraint for bladder, rectum, and sigmoid, respectively. CONCLUSIONS: bICRU was not representative of bladder D2cc and resulted in different total dose. rICRU was found to be similar to D2cc dose and was reliable in total dose computation. Our current institutional practice of point-based planning in ICBT resulted in significant number of patients’ OARs doses exceeded the volume constraint, because the total dose concept was not used propectively in planning. Termedia Publishing House 2010-04-01 2010-03 /pmc/articles/PMC5183646/ /pubmed/28031742 http://dx.doi.org/10.5114/jcb.2010.13721 Text en Copyright: © 2010 Termedia Sp. z o. o. http://creativecommons.org/licenses/by-nc-sa/4.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 International (CC BY-NC-SA 4.0) License, allowing third parties to copy and redistribute the material in any medium or format and to remix, transform, and build upon the material, provided the original work is properly cited and states its license.
spellingShingle Original Article
Tan, Yun Inn
Choo, Bok Ai
Lee, Khai Mun
2D to 3D Evaluation of Organs at Risk Doses in Intracavitary Brachytherapy for Cervical Cancer
title 2D to 3D Evaluation of Organs at Risk Doses in Intracavitary Brachytherapy for Cervical Cancer
title_full 2D to 3D Evaluation of Organs at Risk Doses in Intracavitary Brachytherapy for Cervical Cancer
title_fullStr 2D to 3D Evaluation of Organs at Risk Doses in Intracavitary Brachytherapy for Cervical Cancer
title_full_unstemmed 2D to 3D Evaluation of Organs at Risk Doses in Intracavitary Brachytherapy for Cervical Cancer
title_short 2D to 3D Evaluation of Organs at Risk Doses in Intracavitary Brachytherapy for Cervical Cancer
title_sort 2d to 3d evaluation of organs at risk doses in intracavitary brachytherapy for cervical cancer
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5183646/
https://www.ncbi.nlm.nih.gov/pubmed/28031742
http://dx.doi.org/10.5114/jcb.2010.13721
work_keys_str_mv AT tanyuninn 2dto3devaluationoforgansatriskdosesinintracavitarybrachytherapyforcervicalcancer
AT choobokai 2dto3devaluationoforgansatriskdosesinintracavitarybrachytherapyforcervicalcancer
AT leekhaimun 2dto3devaluationoforgansatriskdosesinintracavitarybrachytherapyforcervicalcancer