Basket-Type Catheters: Diagnostic Pitfalls Caused by Deformation and Limited Coverage
Whole-chamber mapping using a 64-pole basket catheter (BC) has become a featured approach for the analysis of excitation patterns during atrial fibrillation. A flexible catheter design avoids perforation but may lead to spline bunching and influence coverage. We aim to quantify the catheter deformat...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5187596/ https://www.ncbi.nlm.nih.gov/pubmed/28070511 http://dx.doi.org/10.1155/2016/5340574 |
_version_ | 1782486875198455808 |
---|---|
author | Oesterlein, Tobias Frisch, Daniel Loewe, Axel Seemann, Gunnar Schmitt, Claus Dössel, Olaf Luik, Armin |
author_facet | Oesterlein, Tobias Frisch, Daniel Loewe, Axel Seemann, Gunnar Schmitt, Claus Dössel, Olaf Luik, Armin |
author_sort | Oesterlein, Tobias |
collection | PubMed |
description | Whole-chamber mapping using a 64-pole basket catheter (BC) has become a featured approach for the analysis of excitation patterns during atrial fibrillation. A flexible catheter design avoids perforation but may lead to spline bunching and influence coverage. We aim to quantify the catheter deformation and endocardial coverage in clinical situations and study the effect of catheter size and electrode arrangement using an in silico basket model. Atrial coverage and spline separation were evaluated quantitatively in an ensemble of clinical measurements. A computational model of the BC was implemented including an algorithm to adapt its shape to the atrial anatomy. Two clinically relevant mapping positions in each atrium were assessed in both clinical and simulated data. The simulation environment allowed varying both BC size and electrode arrangement. Results showed that interspline distances of more than 20 mm are common, leading to a coverage of less than 50% of the left atrial (LA) surface. In an ideal in silico scenario with variable catheter designs, a maximum coverage of 65% could be reached. As spline bunching and insufficient coverage can hardly be avoided, this has to be taken into account for interpretation of excitation patterns and development of new panoramic mapping techniques. |
format | Online Article Text |
id | pubmed-5187596 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-51875962017-01-09 Basket-Type Catheters: Diagnostic Pitfalls Caused by Deformation and Limited Coverage Oesterlein, Tobias Frisch, Daniel Loewe, Axel Seemann, Gunnar Schmitt, Claus Dössel, Olaf Luik, Armin Biomed Res Int Research Article Whole-chamber mapping using a 64-pole basket catheter (BC) has become a featured approach for the analysis of excitation patterns during atrial fibrillation. A flexible catheter design avoids perforation but may lead to spline bunching and influence coverage. We aim to quantify the catheter deformation and endocardial coverage in clinical situations and study the effect of catheter size and electrode arrangement using an in silico basket model. Atrial coverage and spline separation were evaluated quantitatively in an ensemble of clinical measurements. A computational model of the BC was implemented including an algorithm to adapt its shape to the atrial anatomy. Two clinically relevant mapping positions in each atrium were assessed in both clinical and simulated data. The simulation environment allowed varying both BC size and electrode arrangement. Results showed that interspline distances of more than 20 mm are common, leading to a coverage of less than 50% of the left atrial (LA) surface. In an ideal in silico scenario with variable catheter designs, a maximum coverage of 65% could be reached. As spline bunching and insufficient coverage can hardly be avoided, this has to be taken into account for interpretation of excitation patterns and development of new panoramic mapping techniques. Hindawi Publishing Corporation 2016 2016-12-13 /pmc/articles/PMC5187596/ /pubmed/28070511 http://dx.doi.org/10.1155/2016/5340574 Text en Copyright © 2016 Tobias Oesterlein et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Oesterlein, Tobias Frisch, Daniel Loewe, Axel Seemann, Gunnar Schmitt, Claus Dössel, Olaf Luik, Armin Basket-Type Catheters: Diagnostic Pitfalls Caused by Deformation and Limited Coverage |
title | Basket-Type Catheters: Diagnostic Pitfalls Caused by Deformation and Limited Coverage |
title_full | Basket-Type Catheters: Diagnostic Pitfalls Caused by Deformation and Limited Coverage |
title_fullStr | Basket-Type Catheters: Diagnostic Pitfalls Caused by Deformation and Limited Coverage |
title_full_unstemmed | Basket-Type Catheters: Diagnostic Pitfalls Caused by Deformation and Limited Coverage |
title_short | Basket-Type Catheters: Diagnostic Pitfalls Caused by Deformation and Limited Coverage |
title_sort | basket-type catheters: diagnostic pitfalls caused by deformation and limited coverage |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5187596/ https://www.ncbi.nlm.nih.gov/pubmed/28070511 http://dx.doi.org/10.1155/2016/5340574 |
work_keys_str_mv | AT oesterleintobias baskettypecathetersdiagnosticpitfallscausedbydeformationandlimitedcoverage AT frischdaniel baskettypecathetersdiagnosticpitfallscausedbydeformationandlimitedcoverage AT loeweaxel baskettypecathetersdiagnosticpitfallscausedbydeformationandlimitedcoverage AT seemanngunnar baskettypecathetersdiagnosticpitfallscausedbydeformationandlimitedcoverage AT schmittclaus baskettypecathetersdiagnosticpitfallscausedbydeformationandlimitedcoverage AT dosselolaf baskettypecathetersdiagnosticpitfallscausedbydeformationandlimitedcoverage AT luikarmin baskettypecathetersdiagnosticpitfallscausedbydeformationandlimitedcoverage |