Cargando…
Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor
For asymmetric laser beams, the values of beam quality factor [Formula: see text] and [Formula: see text] are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniquenes...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5190995/ https://www.ncbi.nlm.nih.gov/pubmed/27916845 http://dx.doi.org/10.3390/s16122014 |
_version_ | 1782487530695819264 |
---|---|
author | Du, Yongzhao |
author_facet | Du, Yongzhao |
author_sort | Du, Yongzhao |
collection | PubMed |
description | For asymmetric laser beams, the values of beam quality factor [Formula: see text] and [Formula: see text] are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniqueness, a new beam quality characterization method named as M(2)-curve is developed. The M(2)-curve not only contains the beam quality factor [Formula: see text] and [Formula: see text] in the x-direction and y-direction, respectively; but also introduces a curve of [Formula: see text] versus rotation angle α of coordinate axis. Moreover, we also present a real-time measurement method to demonstrate beam propagation factor M(2)-curve with a modified self-referencing Mach-Zehnder interferometer based-wavefront sensor (henceforth SRI-WFS). The feasibility of the proposed method is demonstrated with the theoretical analysis and experiment in multimode beams. The experimental results showed that the proposed measurement method is simple, fast, and a single-shot measurement procedure without movable parts. |
format | Online Article Text |
id | pubmed-5190995 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-51909952017-01-03 Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor Du, Yongzhao Sensors (Basel) Article For asymmetric laser beams, the values of beam quality factor [Formula: see text] and [Formula: see text] are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniqueness, a new beam quality characterization method named as M(2)-curve is developed. The M(2)-curve not only contains the beam quality factor [Formula: see text] and [Formula: see text] in the x-direction and y-direction, respectively; but also introduces a curve of [Formula: see text] versus rotation angle α of coordinate axis. Moreover, we also present a real-time measurement method to demonstrate beam propagation factor M(2)-curve with a modified self-referencing Mach-Zehnder interferometer based-wavefront sensor (henceforth SRI-WFS). The feasibility of the proposed method is demonstrated with the theoretical analysis and experiment in multimode beams. The experimental results showed that the proposed measurement method is simple, fast, and a single-shot measurement procedure without movable parts. MDPI 2016-11-29 /pmc/articles/PMC5190995/ /pubmed/27916845 http://dx.doi.org/10.3390/s16122014 Text en © 2016 by the author; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Du, Yongzhao Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor |
title | Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor |
title_full | Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor |
title_fullStr | Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor |
title_full_unstemmed | Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor |
title_short | Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor |
title_sort | measurement of m(2)-curve for asymmetric beams by self-referencing interferometer wavefront sensor |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5190995/ https://www.ncbi.nlm.nih.gov/pubmed/27916845 http://dx.doi.org/10.3390/s16122014 |
work_keys_str_mv | AT duyongzhao measurementofm2curveforasymmetricbeamsbyselfreferencinginterferometerwavefrontsensor |