Cargando…

Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor

For asymmetric laser beams, the values of beam quality factor [Formula: see text] and [Formula: see text] are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniquenes...

Descripción completa

Detalles Bibliográficos
Autor principal: Du, Yongzhao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5190995/
https://www.ncbi.nlm.nih.gov/pubmed/27916845
http://dx.doi.org/10.3390/s16122014
_version_ 1782487530695819264
author Du, Yongzhao
author_facet Du, Yongzhao
author_sort Du, Yongzhao
collection PubMed
description For asymmetric laser beams, the values of beam quality factor [Formula: see text] and [Formula: see text] are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniqueness, a new beam quality characterization method named as M(2)-curve is developed. The M(2)-curve not only contains the beam quality factor [Formula: see text] and [Formula: see text] in the x-direction and y-direction, respectively; but also introduces a curve of [Formula: see text] versus rotation angle α of coordinate axis. Moreover, we also present a real-time measurement method to demonstrate beam propagation factor M(2)-curve with a modified self-referencing Mach-Zehnder interferometer based-wavefront sensor (henceforth SRI-WFS). The feasibility of the proposed method is demonstrated with the theoretical analysis and experiment in multimode beams. The experimental results showed that the proposed measurement method is simple, fast, and a single-shot measurement procedure without movable parts.
format Online
Article
Text
id pubmed-5190995
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-51909952017-01-03 Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor Du, Yongzhao Sensors (Basel) Article For asymmetric laser beams, the values of beam quality factor [Formula: see text] and [Formula: see text] are inconsistent if one selects a different coordinate system or measures beam quality with different experimental conditionals, even when analyzing the same beam. To overcome this non-uniqueness, a new beam quality characterization method named as M(2)-curve is developed. The M(2)-curve not only contains the beam quality factor [Formula: see text] and [Formula: see text] in the x-direction and y-direction, respectively; but also introduces a curve of [Formula: see text] versus rotation angle α of coordinate axis. Moreover, we also present a real-time measurement method to demonstrate beam propagation factor M(2)-curve with a modified self-referencing Mach-Zehnder interferometer based-wavefront sensor (henceforth SRI-WFS). The feasibility of the proposed method is demonstrated with the theoretical analysis and experiment in multimode beams. The experimental results showed that the proposed measurement method is simple, fast, and a single-shot measurement procedure without movable parts. MDPI 2016-11-29 /pmc/articles/PMC5190995/ /pubmed/27916845 http://dx.doi.org/10.3390/s16122014 Text en © 2016 by the author; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Du, Yongzhao
Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor
title Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor
title_full Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor
title_fullStr Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor
title_full_unstemmed Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor
title_short Measurement of M(2)-Curve for Asymmetric Beams by Self-Referencing Interferometer Wavefront Sensor
title_sort measurement of m(2)-curve for asymmetric beams by self-referencing interferometer wavefront sensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5190995/
https://www.ncbi.nlm.nih.gov/pubmed/27916845
http://dx.doi.org/10.3390/s16122014
work_keys_str_mv AT duyongzhao measurementofm2curveforasymmetricbeamsbyselfreferencinginterferometerwavefrontsensor