Cargando…

Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study

PURPOSE: To evaluate in unselected patients imaged under routine conditions the co-registration accuracy of elastic fusion between magnetic resonance (MR) and ultrasound (US) images obtained by the Koelis Urostation(™). MATERIALS AND METHODS: We prospectively included 15 consecutive patients referre...

Descripción completa

Detalles Bibliográficos
Autores principales: Moldovan, Paul, Udrescu, Corina, Ravier, Emmanuel, Souchon, Rémi, Rabilloud, Muriel, Bratan, Flavie, Sanzalone, Thomas, Cros, Fanny, Crouzet, Sébastien, Gelet, Albert, Chapet, Olivier, Rouvière, Olivier
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5199076/
https://www.ncbi.nlm.nih.gov/pubmed/28033423
http://dx.doi.org/10.1371/journal.pone.0169120
_version_ 1782488942108475392
author Moldovan, Paul
Udrescu, Corina
Ravier, Emmanuel
Souchon, Rémi
Rabilloud, Muriel
Bratan, Flavie
Sanzalone, Thomas
Cros, Fanny
Crouzet, Sébastien
Gelet, Albert
Chapet, Olivier
Rouvière, Olivier
author_facet Moldovan, Paul
Udrescu, Corina
Ravier, Emmanuel
Souchon, Rémi
Rabilloud, Muriel
Bratan, Flavie
Sanzalone, Thomas
Cros, Fanny
Crouzet, Sébastien
Gelet, Albert
Chapet, Olivier
Rouvière, Olivier
author_sort Moldovan, Paul
collection PubMed
description PURPOSE: To evaluate in unselected patients imaged under routine conditions the co-registration accuracy of elastic fusion between magnetic resonance (MR) and ultrasound (US) images obtained by the Koelis Urostation(™). MATERIALS AND METHODS: We prospectively included 15 consecutive patients referred for placement of intraprostatic fiducials before radiotherapy and who gave written informed consent by signing the Institutional Review Board-approved forms. Three fiducials were placed in the prostate under US guidance in standardized positions (right apex, left mid-gland, right base) using the Koelis Urostation(™). Patients then underwent prostate MR imaging. Four operators outlined the prostate on MR and US images and an elastic fusion was retrospectively performed. Fiducials were used to measure the overall target registration error (TRE(3D)), the error along the antero-posterior (TRE(AP)), right-left (TRE(RL)) and head-feet (TRE(HF)) directions, and within the plane orthogonal to the virtual biopsy track (TRE(2D)). RESULTS: Median TRE(3D) and TRE(2D) were 3.8–5.6 mm, and 2.5–3.6 mm, respectively. TRE(3D) was significantly influenced by the operator (p = 0.013), fiducial location (p = 0.001) and 3D axis orientation (p<0.0001). The worst results were obtained by the least experienced operator. TRE(3D) was smaller in mid-gland and base than in apex (average difference: -1.21 mm (95% confidence interval (95%CI): -2.03; -0.4) and -1.56 mm (95%CI: -2.44; -0.69) respectively). TRE(AP) and TRE(HF) were larger than TRE(RL) (average difference: +1.29 mm (95%CI: +0.87; +1.71) and +0.59 mm (95%CI: +0.1; +0.95) respectively). CONCLUSIONS: Registration error values were reasonable for clinical practice. The co-registration accuracy was significantly influenced by the operator’s experience, and significantly poorer in the antero-posterior direction and at the apex.
format Online
Article
Text
id pubmed-5199076
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-51990762017-01-19 Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study Moldovan, Paul Udrescu, Corina Ravier, Emmanuel Souchon, Rémi Rabilloud, Muriel Bratan, Flavie Sanzalone, Thomas Cros, Fanny Crouzet, Sébastien Gelet, Albert Chapet, Olivier Rouvière, Olivier PLoS One Research Article PURPOSE: To evaluate in unselected patients imaged under routine conditions the co-registration accuracy of elastic fusion between magnetic resonance (MR) and ultrasound (US) images obtained by the Koelis Urostation(™). MATERIALS AND METHODS: We prospectively included 15 consecutive patients referred for placement of intraprostatic fiducials before radiotherapy and who gave written informed consent by signing the Institutional Review Board-approved forms. Three fiducials were placed in the prostate under US guidance in standardized positions (right apex, left mid-gland, right base) using the Koelis Urostation(™). Patients then underwent prostate MR imaging. Four operators outlined the prostate on MR and US images and an elastic fusion was retrospectively performed. Fiducials were used to measure the overall target registration error (TRE(3D)), the error along the antero-posterior (TRE(AP)), right-left (TRE(RL)) and head-feet (TRE(HF)) directions, and within the plane orthogonal to the virtual biopsy track (TRE(2D)). RESULTS: Median TRE(3D) and TRE(2D) were 3.8–5.6 mm, and 2.5–3.6 mm, respectively. TRE(3D) was significantly influenced by the operator (p = 0.013), fiducial location (p = 0.001) and 3D axis orientation (p<0.0001). The worst results were obtained by the least experienced operator. TRE(3D) was smaller in mid-gland and base than in apex (average difference: -1.21 mm (95% confidence interval (95%CI): -2.03; -0.4) and -1.56 mm (95%CI: -2.44; -0.69) respectively). TRE(AP) and TRE(HF) were larger than TRE(RL) (average difference: +1.29 mm (95%CI: +0.87; +1.71) and +0.59 mm (95%CI: +0.1; +0.95) respectively). CONCLUSIONS: Registration error values were reasonable for clinical practice. The co-registration accuracy was significantly influenced by the operator’s experience, and significantly poorer in the antero-posterior direction and at the apex. Public Library of Science 2016-12-29 /pmc/articles/PMC5199076/ /pubmed/28033423 http://dx.doi.org/10.1371/journal.pone.0169120 Text en © 2016 Moldovan et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Moldovan, Paul
Udrescu, Corina
Ravier, Emmanuel
Souchon, Rémi
Rabilloud, Muriel
Bratan, Flavie
Sanzalone, Thomas
Cros, Fanny
Crouzet, Sébastien
Gelet, Albert
Chapet, Olivier
Rouvière, Olivier
Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study
title Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study
title_full Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study
title_fullStr Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study
title_full_unstemmed Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study
title_short Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study
title_sort accuracy of elastic fusion of prostate magnetic resonance and transrectal ultrasound images under routine conditions: a prospective multi-operator study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5199076/
https://www.ncbi.nlm.nih.gov/pubmed/28033423
http://dx.doi.org/10.1371/journal.pone.0169120
work_keys_str_mv AT moldovanpaul accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy
AT udrescucorina accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy
AT ravieremmanuel accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy
AT souchonremi accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy
AT rabilloudmuriel accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy
AT bratanflavie accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy
AT sanzalonethomas accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy
AT crosfanny accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy
AT crouzetsebastien accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy
AT geletalbert accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy
AT chapetolivier accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy
AT rouviereolivier accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy