Cargando…
Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study
PURPOSE: To evaluate in unselected patients imaged under routine conditions the co-registration accuracy of elastic fusion between magnetic resonance (MR) and ultrasound (US) images obtained by the Koelis Urostation(™). MATERIALS AND METHODS: We prospectively included 15 consecutive patients referre...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5199076/ https://www.ncbi.nlm.nih.gov/pubmed/28033423 http://dx.doi.org/10.1371/journal.pone.0169120 |
_version_ | 1782488942108475392 |
---|---|
author | Moldovan, Paul Udrescu, Corina Ravier, Emmanuel Souchon, Rémi Rabilloud, Muriel Bratan, Flavie Sanzalone, Thomas Cros, Fanny Crouzet, Sébastien Gelet, Albert Chapet, Olivier Rouvière, Olivier |
author_facet | Moldovan, Paul Udrescu, Corina Ravier, Emmanuel Souchon, Rémi Rabilloud, Muriel Bratan, Flavie Sanzalone, Thomas Cros, Fanny Crouzet, Sébastien Gelet, Albert Chapet, Olivier Rouvière, Olivier |
author_sort | Moldovan, Paul |
collection | PubMed |
description | PURPOSE: To evaluate in unselected patients imaged under routine conditions the co-registration accuracy of elastic fusion between magnetic resonance (MR) and ultrasound (US) images obtained by the Koelis Urostation(™). MATERIALS AND METHODS: We prospectively included 15 consecutive patients referred for placement of intraprostatic fiducials before radiotherapy and who gave written informed consent by signing the Institutional Review Board-approved forms. Three fiducials were placed in the prostate under US guidance in standardized positions (right apex, left mid-gland, right base) using the Koelis Urostation(™). Patients then underwent prostate MR imaging. Four operators outlined the prostate on MR and US images and an elastic fusion was retrospectively performed. Fiducials were used to measure the overall target registration error (TRE(3D)), the error along the antero-posterior (TRE(AP)), right-left (TRE(RL)) and head-feet (TRE(HF)) directions, and within the plane orthogonal to the virtual biopsy track (TRE(2D)). RESULTS: Median TRE(3D) and TRE(2D) were 3.8–5.6 mm, and 2.5–3.6 mm, respectively. TRE(3D) was significantly influenced by the operator (p = 0.013), fiducial location (p = 0.001) and 3D axis orientation (p<0.0001). The worst results were obtained by the least experienced operator. TRE(3D) was smaller in mid-gland and base than in apex (average difference: -1.21 mm (95% confidence interval (95%CI): -2.03; -0.4) and -1.56 mm (95%CI: -2.44; -0.69) respectively). TRE(AP) and TRE(HF) were larger than TRE(RL) (average difference: +1.29 mm (95%CI: +0.87; +1.71) and +0.59 mm (95%CI: +0.1; +0.95) respectively). CONCLUSIONS: Registration error values were reasonable for clinical practice. The co-registration accuracy was significantly influenced by the operator’s experience, and significantly poorer in the antero-posterior direction and at the apex. |
format | Online Article Text |
id | pubmed-5199076 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-51990762017-01-19 Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study Moldovan, Paul Udrescu, Corina Ravier, Emmanuel Souchon, Rémi Rabilloud, Muriel Bratan, Flavie Sanzalone, Thomas Cros, Fanny Crouzet, Sébastien Gelet, Albert Chapet, Olivier Rouvière, Olivier PLoS One Research Article PURPOSE: To evaluate in unselected patients imaged under routine conditions the co-registration accuracy of elastic fusion between magnetic resonance (MR) and ultrasound (US) images obtained by the Koelis Urostation(™). MATERIALS AND METHODS: We prospectively included 15 consecutive patients referred for placement of intraprostatic fiducials before radiotherapy and who gave written informed consent by signing the Institutional Review Board-approved forms. Three fiducials were placed in the prostate under US guidance in standardized positions (right apex, left mid-gland, right base) using the Koelis Urostation(™). Patients then underwent prostate MR imaging. Four operators outlined the prostate on MR and US images and an elastic fusion was retrospectively performed. Fiducials were used to measure the overall target registration error (TRE(3D)), the error along the antero-posterior (TRE(AP)), right-left (TRE(RL)) and head-feet (TRE(HF)) directions, and within the plane orthogonal to the virtual biopsy track (TRE(2D)). RESULTS: Median TRE(3D) and TRE(2D) were 3.8–5.6 mm, and 2.5–3.6 mm, respectively. TRE(3D) was significantly influenced by the operator (p = 0.013), fiducial location (p = 0.001) and 3D axis orientation (p<0.0001). The worst results were obtained by the least experienced operator. TRE(3D) was smaller in mid-gland and base than in apex (average difference: -1.21 mm (95% confidence interval (95%CI): -2.03; -0.4) and -1.56 mm (95%CI: -2.44; -0.69) respectively). TRE(AP) and TRE(HF) were larger than TRE(RL) (average difference: +1.29 mm (95%CI: +0.87; +1.71) and +0.59 mm (95%CI: +0.1; +0.95) respectively). CONCLUSIONS: Registration error values were reasonable for clinical practice. The co-registration accuracy was significantly influenced by the operator’s experience, and significantly poorer in the antero-posterior direction and at the apex. Public Library of Science 2016-12-29 /pmc/articles/PMC5199076/ /pubmed/28033423 http://dx.doi.org/10.1371/journal.pone.0169120 Text en © 2016 Moldovan et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Moldovan, Paul Udrescu, Corina Ravier, Emmanuel Souchon, Rémi Rabilloud, Muriel Bratan, Flavie Sanzalone, Thomas Cros, Fanny Crouzet, Sébastien Gelet, Albert Chapet, Olivier Rouvière, Olivier Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study |
title | Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study |
title_full | Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study |
title_fullStr | Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study |
title_full_unstemmed | Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study |
title_short | Accuracy of Elastic Fusion of Prostate Magnetic Resonance and Transrectal Ultrasound Images under Routine Conditions: A Prospective Multi-Operator Study |
title_sort | accuracy of elastic fusion of prostate magnetic resonance and transrectal ultrasound images under routine conditions: a prospective multi-operator study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5199076/ https://www.ncbi.nlm.nih.gov/pubmed/28033423 http://dx.doi.org/10.1371/journal.pone.0169120 |
work_keys_str_mv | AT moldovanpaul accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy AT udrescucorina accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy AT ravieremmanuel accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy AT souchonremi accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy AT rabilloudmuriel accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy AT bratanflavie accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy AT sanzalonethomas accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy AT crosfanny accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy AT crouzetsebastien accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy AT geletalbert accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy AT chapetolivier accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy AT rouviereolivier accuracyofelasticfusionofprostatemagneticresonanceandtransrectalultrasoundimagesunderroutineconditionsaprospectivemultioperatorstudy |