Cargando…
Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity
Fluorescence probes represent an attractive solution for the detection of the biologically important Cu(i) cation; however, achieving a bright, high-contrast response has been a challenging goal. Concluding from previous studies on pyrazoline-based fluorescent Cu(i) probes, the maximum attainable fl...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Royal Society of Chemistry
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5201193/ https://www.ncbi.nlm.nih.gov/pubmed/28042469 http://dx.doi.org/10.1039/c5sc03643g |
_version_ | 1782489300830519296 |
---|---|
author | Morgan, M. T. McCallum, A. M. Fahrni, C. J. |
author_facet | Morgan, M. T. McCallum, A. M. Fahrni, C. J. |
author_sort | Morgan, M. T. |
collection | PubMed |
description | Fluorescence probes represent an attractive solution for the detection of the biologically important Cu(i) cation; however, achieving a bright, high-contrast response has been a challenging goal. Concluding from previous studies on pyrazoline-based fluorescent Cu(i) probes, the maximum attainable fluorescence contrast and quantum yield were limited due to several non-radiative deactivation mechanisms, including ternary complex formation, excited state protonation, and colloidal aggregation in aqueous solution. Through knowledge-driven optimization of the ligand and fluorophore architectures, we overcame these limitations in the design of CTAP-3, a Cu(i)-selective fluorescent probe offering a 180-fold fluorescence enhancement, 41% quantum yield, and a limit of detection in the sub-part-per-trillion concentration range. In contrast to lipophilic Cu(i)-probes, CTAP-3 does not aggregate and interacts only weakly with lipid bilayers, thus maintaining a high contrast ratio even in the presence of liposomes. |
format | Online Article Text |
id | pubmed-5201193 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Royal Society of Chemistry |
record_format | MEDLINE/PubMed |
spelling | pubmed-52011932016-12-30 Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity Morgan, M. T. McCallum, A. M. Fahrni, C. J. Chem Sci Chemistry Fluorescence probes represent an attractive solution for the detection of the biologically important Cu(i) cation; however, achieving a bright, high-contrast response has been a challenging goal. Concluding from previous studies on pyrazoline-based fluorescent Cu(i) probes, the maximum attainable fluorescence contrast and quantum yield were limited due to several non-radiative deactivation mechanisms, including ternary complex formation, excited state protonation, and colloidal aggregation in aqueous solution. Through knowledge-driven optimization of the ligand and fluorophore architectures, we overcame these limitations in the design of CTAP-3, a Cu(i)-selective fluorescent probe offering a 180-fold fluorescence enhancement, 41% quantum yield, and a limit of detection in the sub-part-per-trillion concentration range. In contrast to lipophilic Cu(i)-probes, CTAP-3 does not aggregate and interacts only weakly with lipid bilayers, thus maintaining a high contrast ratio even in the presence of liposomes. Royal Society of Chemistry 2016-02-01 2015-12-01 /pmc/articles/PMC5201193/ /pubmed/28042469 http://dx.doi.org/10.1039/c5sc03643g Text en This journal is © The Royal Society of Chemistry 2016 http://creativecommons.org/licenses/by/3.0/ This article is freely available. This article is licensed under a Creative Commons Attribution 3.0 Unported Licence (CC BY 3.0) |
spellingShingle | Chemistry Morgan, M. T. McCallum, A. M. Fahrni, C. J. Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity |
title | Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity
|
title_full | Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity
|
title_fullStr | Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity
|
title_full_unstemmed | Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity
|
title_short | Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity
|
title_sort | rational design of a water-soluble, lipid-compatible fluorescent probe for cu(i) with sub-part-per-trillion sensitivity |
topic | Chemistry |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5201193/ https://www.ncbi.nlm.nih.gov/pubmed/28042469 http://dx.doi.org/10.1039/c5sc03643g |
work_keys_str_mv | AT morganmt rationaldesignofawatersolublelipidcompatiblefluorescentprobeforcuiwithsubpartpertrillionsensitivity AT mccallumam rationaldesignofawatersolublelipidcompatiblefluorescentprobeforcuiwithsubpartpertrillionsensitivity AT fahrnicj rationaldesignofawatersolublelipidcompatiblefluorescentprobeforcuiwithsubpartpertrillionsensitivity |