Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity

Fluorescence probes represent an attractive solution for the detection of the biologically important Cu(i) cation; however, achieving a bright, high-contrast response has been a challenging goal. Concluding from previous studies on pyrazoline-based fluorescent Cu(i) probes, the maximum attainable fl...

Descripción completa

Detalles Bibliográficos
Autores principales: Morgan, M. T., McCallum, A. M., Fahrni, C. J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Royal Society of Chemistry 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5201193/
https://www.ncbi.nlm.nih.gov/pubmed/28042469
http://dx.doi.org/10.1039/c5sc03643g
_version_ 1782489300830519296
author Morgan, M. T.
McCallum, A. M.
Fahrni, C. J.
author_facet Morgan, M. T.
McCallum, A. M.
Fahrni, C. J.
author_sort Morgan, M. T.
collection PubMed
description Fluorescence probes represent an attractive solution for the detection of the biologically important Cu(i) cation; however, achieving a bright, high-contrast response has been a challenging goal. Concluding from previous studies on pyrazoline-based fluorescent Cu(i) probes, the maximum attainable fluorescence contrast and quantum yield were limited due to several non-radiative deactivation mechanisms, including ternary complex formation, excited state protonation, and colloidal aggregation in aqueous solution. Through knowledge-driven optimization of the ligand and fluorophore architectures, we overcame these limitations in the design of CTAP-3, a Cu(i)-selective fluorescent probe offering a 180-fold fluorescence enhancement, 41% quantum yield, and a limit of detection in the sub-part-per-trillion concentration range. In contrast to lipophilic Cu(i)-probes, CTAP-3 does not aggregate and interacts only weakly with lipid bilayers, thus maintaining a high contrast ratio even in the presence of liposomes.
format Online
Article
Text
id pubmed-5201193
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Royal Society of Chemistry
record_format MEDLINE/PubMed
spelling pubmed-52011932016-12-30 Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity Morgan, M. T. McCallum, A. M. Fahrni, C. J. Chem Sci Chemistry Fluorescence probes represent an attractive solution for the detection of the biologically important Cu(i) cation; however, achieving a bright, high-contrast response has been a challenging goal. Concluding from previous studies on pyrazoline-based fluorescent Cu(i) probes, the maximum attainable fluorescence contrast and quantum yield were limited due to several non-radiative deactivation mechanisms, including ternary complex formation, excited state protonation, and colloidal aggregation in aqueous solution. Through knowledge-driven optimization of the ligand and fluorophore architectures, we overcame these limitations in the design of CTAP-3, a Cu(i)-selective fluorescent probe offering a 180-fold fluorescence enhancement, 41% quantum yield, and a limit of detection in the sub-part-per-trillion concentration range. In contrast to lipophilic Cu(i)-probes, CTAP-3 does not aggregate and interacts only weakly with lipid bilayers, thus maintaining a high contrast ratio even in the presence of liposomes. Royal Society of Chemistry 2016-02-01 2015-12-01 /pmc/articles/PMC5201193/ /pubmed/28042469 http://dx.doi.org/10.1039/c5sc03643g Text en This journal is © The Royal Society of Chemistry 2016 http://creativecommons.org/licenses/by/3.0/ This article is freely available. This article is licensed under a Creative Commons Attribution 3.0 Unported Licence (CC BY 3.0)
spellingShingle Chemistry
Morgan, M. T.
McCallum, A. M.
Fahrni, C. J.
Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity
title Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity
title_full Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity
title_fullStr Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity
title_full_unstemmed Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity
title_short Rational design of a water-soluble, lipid-compatible fluorescent probe for Cu(i) with sub-part-per-trillion sensitivity
title_sort rational design of a water-soluble, lipid-compatible fluorescent probe for cu(i) with sub-part-per-trillion sensitivity
topic Chemistry
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5201193/
https://www.ncbi.nlm.nih.gov/pubmed/28042469
http://dx.doi.org/10.1039/c5sc03643g
work_keys_str_mv AT morganmt rationaldesignofawatersolublelipidcompatiblefluorescentprobeforcuiwithsubpartpertrillionsensitivity
AT mccallumam rationaldesignofawatersolublelipidcompatiblefluorescentprobeforcuiwithsubpartpertrillionsensitivity
AT fahrnicj rationaldesignofawatersolublelipidcompatiblefluorescentprobeforcuiwithsubpartpertrillionsensitivity