Cargando…

On-Line Monitoring the Growth of E. coli or HeLa Cells Using an Annular Microelectrode Piezoelectric Biosensor

Biological information is obtained from the interaction between the series detection electrode and the organism or the physical field of biological cultures in the non-mass responsive piezoelectric biosensor. Therefore, electric parameter of the electrode will affect the biosensor signal. The electr...

Descripción completa

Detalles Bibliográficos
Autores principales: Tong, Feifei, Lian, Yan, Han, Junliang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5201395/
https://www.ncbi.nlm.nih.gov/pubmed/27999343
http://dx.doi.org/10.3390/ijerph13121254
_version_ 1782489339885780992
author Tong, Feifei
Lian, Yan
Han, Junliang
author_facet Tong, Feifei
Lian, Yan
Han, Junliang
author_sort Tong, Feifei
collection PubMed
description Biological information is obtained from the interaction between the series detection electrode and the organism or the physical field of biological cultures in the non-mass responsive piezoelectric biosensor. Therefore, electric parameter of the electrode will affect the biosensor signal. The electric field distribution of the microelectrode used in this study was simulated using the COMSOL Multiphysics analytical tool. This process showed that the electric field spatial distribution is affected by the width of the electrode finger or the space between the electrodes. In addition, the characteristic response of the piezoelectric sensor constructed serially with an annular microelectrode was tested and applied for the continuous detection of Escherichia coli culture or HeLa cell culture. Results indicated that the piezoelectric biosensor with an annular microelectrode meets the requirements for the real-time detection of E. coli or HeLa cells in culture. Moreover, this kind of piezoelectric biosensor is more sensitive than the sensor with an interdigital microelectrode. Thus, the piezoelectric biosensor acts as an effective analysis tool for acquiring online cell or microbial culture information.
format Online
Article
Text
id pubmed-5201395
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-52013952016-12-30 On-Line Monitoring the Growth of E. coli or HeLa Cells Using an Annular Microelectrode Piezoelectric Biosensor Tong, Feifei Lian, Yan Han, Junliang Int J Environ Res Public Health Article Biological information is obtained from the interaction between the series detection electrode and the organism or the physical field of biological cultures in the non-mass responsive piezoelectric biosensor. Therefore, electric parameter of the electrode will affect the biosensor signal. The electric field distribution of the microelectrode used in this study was simulated using the COMSOL Multiphysics analytical tool. This process showed that the electric field spatial distribution is affected by the width of the electrode finger or the space between the electrodes. In addition, the characteristic response of the piezoelectric sensor constructed serially with an annular microelectrode was tested and applied for the continuous detection of Escherichia coli culture or HeLa cell culture. Results indicated that the piezoelectric biosensor with an annular microelectrode meets the requirements for the real-time detection of E. coli or HeLa cells in culture. Moreover, this kind of piezoelectric biosensor is more sensitive than the sensor with an interdigital microelectrode. Thus, the piezoelectric biosensor acts as an effective analysis tool for acquiring online cell or microbial culture information. MDPI 2016-12-18 2016-12 /pmc/articles/PMC5201395/ /pubmed/27999343 http://dx.doi.org/10.3390/ijerph13121254 Text en © 2016 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC-BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Tong, Feifei
Lian, Yan
Han, Junliang
On-Line Monitoring the Growth of E. coli or HeLa Cells Using an Annular Microelectrode Piezoelectric Biosensor
title On-Line Monitoring the Growth of E. coli or HeLa Cells Using an Annular Microelectrode Piezoelectric Biosensor
title_full On-Line Monitoring the Growth of E. coli or HeLa Cells Using an Annular Microelectrode Piezoelectric Biosensor
title_fullStr On-Line Monitoring the Growth of E. coli or HeLa Cells Using an Annular Microelectrode Piezoelectric Biosensor
title_full_unstemmed On-Line Monitoring the Growth of E. coli or HeLa Cells Using an Annular Microelectrode Piezoelectric Biosensor
title_short On-Line Monitoring the Growth of E. coli or HeLa Cells Using an Annular Microelectrode Piezoelectric Biosensor
title_sort on-line monitoring the growth of e. coli or hela cells using an annular microelectrode piezoelectric biosensor
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5201395/
https://www.ncbi.nlm.nih.gov/pubmed/27999343
http://dx.doi.org/10.3390/ijerph13121254
work_keys_str_mv AT tongfeifei onlinemonitoringthegrowthofecoliorhelacellsusinganannularmicroelectrodepiezoelectricbiosensor
AT lianyan onlinemonitoringthegrowthofecoliorhelacellsusinganannularmicroelectrodepiezoelectricbiosensor
AT hanjunliang onlinemonitoringthegrowthofecoliorhelacellsusinganannularmicroelectrodepiezoelectricbiosensor