Cargando…
Post-mortem computed tomography coaxial cutting needle biopsy to facilitate the detection of bacterioplankton using PCR probes as a diagnostic indicator for drowning
We report for the first time the use of coaxial cutting needle biopsy, guided by post-mortem computed tomography (PMCT), to sample internal body tissues for bacterioplankton PCR analysis to investigate drowning. This technical report describes the biopsy technique, the comparison of the needle biops...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5203821/ https://www.ncbi.nlm.nih.gov/pubmed/27817167 http://dx.doi.org/10.1007/s00414-016-1473-6 |
_version_ | 1782489794561966080 |
---|---|
author | Rutty, Guy N. Johnson, Christopher Amoroso, Jasmin Robinson, Claire Bradley, Carina J. Morgan, Bruno |
author_facet | Rutty, Guy N. Johnson, Christopher Amoroso, Jasmin Robinson, Claire Bradley, Carina J. Morgan, Bruno |
author_sort | Rutty, Guy N. |
collection | PubMed |
description | We report for the first time the use of coaxial cutting needle biopsy, guided by post-mortem computed tomography (PMCT), to sample internal body tissues for bacterioplankton PCR analysis to investigate drowning. This technical report describes the biopsy technique, the comparison of the needle biopsy and the invasive autopsy sampling results, as well as the PMCT and autopsy findings. By using this new biopsy sampling approach for bacterioplankton PCR, we have developed on previous papers describing the minimally invasive PMCT approach for the diagnosis of drowning. When such a system is used, the operator must take all precautions to avoid contamination of the core biopsy samples due to the sensitivity of PCR-based analytic systems. |
format | Online Article Text |
id | pubmed-5203821 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-52038212017-01-13 Post-mortem computed tomography coaxial cutting needle biopsy to facilitate the detection of bacterioplankton using PCR probes as a diagnostic indicator for drowning Rutty, Guy N. Johnson, Christopher Amoroso, Jasmin Robinson, Claire Bradley, Carina J. Morgan, Bruno Int J Legal Med Methods Paper We report for the first time the use of coaxial cutting needle biopsy, guided by post-mortem computed tomography (PMCT), to sample internal body tissues for bacterioplankton PCR analysis to investigate drowning. This technical report describes the biopsy technique, the comparison of the needle biopsy and the invasive autopsy sampling results, as well as the PMCT and autopsy findings. By using this new biopsy sampling approach for bacterioplankton PCR, we have developed on previous papers describing the minimally invasive PMCT approach for the diagnosis of drowning. When such a system is used, the operator must take all precautions to avoid contamination of the core biopsy samples due to the sensitivity of PCR-based analytic systems. Springer Berlin Heidelberg 2016-11-05 2017 /pmc/articles/PMC5203821/ /pubmed/27817167 http://dx.doi.org/10.1007/s00414-016-1473-6 Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Methods Paper Rutty, Guy N. Johnson, Christopher Amoroso, Jasmin Robinson, Claire Bradley, Carina J. Morgan, Bruno Post-mortem computed tomography coaxial cutting needle biopsy to facilitate the detection of bacterioplankton using PCR probes as a diagnostic indicator for drowning |
title | Post-mortem computed tomography coaxial cutting needle biopsy to facilitate the detection of bacterioplankton using PCR probes as a diagnostic indicator for drowning |
title_full | Post-mortem computed tomography coaxial cutting needle biopsy to facilitate the detection of bacterioplankton using PCR probes as a diagnostic indicator for drowning |
title_fullStr | Post-mortem computed tomography coaxial cutting needle biopsy to facilitate the detection of bacterioplankton using PCR probes as a diagnostic indicator for drowning |
title_full_unstemmed | Post-mortem computed tomography coaxial cutting needle biopsy to facilitate the detection of bacterioplankton using PCR probes as a diagnostic indicator for drowning |
title_short | Post-mortem computed tomography coaxial cutting needle biopsy to facilitate the detection of bacterioplankton using PCR probes as a diagnostic indicator for drowning |
title_sort | post-mortem computed tomography coaxial cutting needle biopsy to facilitate the detection of bacterioplankton using pcr probes as a diagnostic indicator for drowning |
topic | Methods Paper |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5203821/ https://www.ncbi.nlm.nih.gov/pubmed/27817167 http://dx.doi.org/10.1007/s00414-016-1473-6 |
work_keys_str_mv | AT ruttyguyn postmortemcomputedtomographycoaxialcuttingneedlebiopsytofacilitatethedetectionofbacterioplanktonusingpcrprobesasadiagnosticindicatorfordrowning AT johnsonchristopher postmortemcomputedtomographycoaxialcuttingneedlebiopsytofacilitatethedetectionofbacterioplanktonusingpcrprobesasadiagnosticindicatorfordrowning AT amorosojasmin postmortemcomputedtomographycoaxialcuttingneedlebiopsytofacilitatethedetectionofbacterioplanktonusingpcrprobesasadiagnosticindicatorfordrowning AT robinsonclaire postmortemcomputedtomographycoaxialcuttingneedlebiopsytofacilitatethedetectionofbacterioplanktonusingpcrprobesasadiagnosticindicatorfordrowning AT bradleycarinaj postmortemcomputedtomographycoaxialcuttingneedlebiopsytofacilitatethedetectionofbacterioplanktonusingpcrprobesasadiagnosticindicatorfordrowning AT morganbruno postmortemcomputedtomographycoaxialcuttingneedlebiopsytofacilitatethedetectionofbacterioplanktonusingpcrprobesasadiagnosticindicatorfordrowning |