Cargando…
Combination of Salivary Gland Ultrasonography and Virtual Touch Quantification for Diagnosis of Sjögren's Syndrome: A Preliminary Study
A total of 136 subjects (51 SS patients, 35 sicca syndrome patients without SS, and 50 healthy volunteers) were enrolled in this study. The mean SWV value for salivary glands of SS patients was statistically higher than that of controls (2.81 ± 0.66 m/s versus 1.85 ± 0.28 m/s for parotid glands and...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi Publishing Corporation
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5203879/ https://www.ncbi.nlm.nih.gov/pubmed/28078285 http://dx.doi.org/10.1155/2016/2793898 |
_version_ | 1782489808647487488 |
---|---|
author | Chen, Shaoqi Wang, Yukai Zhang, Guohong Chen, Shigao |
author_facet | Chen, Shaoqi Wang, Yukai Zhang, Guohong Chen, Shigao |
author_sort | Chen, Shaoqi |
collection | PubMed |
description | A total of 136 subjects (51 SS patients, 35 sicca syndrome patients without SS, and 50 healthy volunteers) were enrolled in this study. The mean SWV value for salivary glands of SS patients was statistically higher than that of controls (2.81 ± 0.66 m/s versus 1.85 ± 0.28 m/s for parotid glands and 2.29 ± 0.34 m/s versus 1.82 ± 0.25 m/s for submandibular glands, resp.). Combining SWV values of parotid and submandibular glands gives a sensitivity of 88.2% (95% CI: 76.1–95.6%) and specificity of 96.0% (95% CI: 86.3–99.5%) at the cutoff point of 2.19 m/s, with an AUROC of 0.954 (95% CI: 0.893–0.986). In addition, combining SGUS score and SWV value yields a sensitivity of 98.0% (95% CI: 89.6–100%), specificity of 90.0% (95% CI: 78.2–96.7%), and AUROC of 0.962 (95% CI: 0.904–0.990). Classification tree considering the sequential use of SGUS score and SWV value achieved 92.1% accuracy for diagnosis of SS. Similarly, the ROC curve of combined SGUS scores and SWV values yields an AUROC of 0.954 (95% CI: 0.885–0.987), sensitivity of 97.1% (95% CI: 85.1–99.9%), and specificity of 92.2% (95% CI: 81.1–97.8%) for separating sicca syndrome patients (without SS) from SS patients. Combining SGUS and VTQ provides a promising tool for diagnosis of SS. |
format | Online Article Text |
id | pubmed-5203879 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Hindawi Publishing Corporation |
record_format | MEDLINE/PubMed |
spelling | pubmed-52038792017-01-11 Combination of Salivary Gland Ultrasonography and Virtual Touch Quantification for Diagnosis of Sjögren's Syndrome: A Preliminary Study Chen, Shaoqi Wang, Yukai Zhang, Guohong Chen, Shigao Biomed Res Int Research Article A total of 136 subjects (51 SS patients, 35 sicca syndrome patients without SS, and 50 healthy volunteers) were enrolled in this study. The mean SWV value for salivary glands of SS patients was statistically higher than that of controls (2.81 ± 0.66 m/s versus 1.85 ± 0.28 m/s for parotid glands and 2.29 ± 0.34 m/s versus 1.82 ± 0.25 m/s for submandibular glands, resp.). Combining SWV values of parotid and submandibular glands gives a sensitivity of 88.2% (95% CI: 76.1–95.6%) and specificity of 96.0% (95% CI: 86.3–99.5%) at the cutoff point of 2.19 m/s, with an AUROC of 0.954 (95% CI: 0.893–0.986). In addition, combining SGUS score and SWV value yields a sensitivity of 98.0% (95% CI: 89.6–100%), specificity of 90.0% (95% CI: 78.2–96.7%), and AUROC of 0.962 (95% CI: 0.904–0.990). Classification tree considering the sequential use of SGUS score and SWV value achieved 92.1% accuracy for diagnosis of SS. Similarly, the ROC curve of combined SGUS scores and SWV values yields an AUROC of 0.954 (95% CI: 0.885–0.987), sensitivity of 97.1% (95% CI: 85.1–99.9%), and specificity of 92.2% (95% CI: 81.1–97.8%) for separating sicca syndrome patients (without SS) from SS patients. Combining SGUS and VTQ provides a promising tool for diagnosis of SS. Hindawi Publishing Corporation 2016 2016-12-18 /pmc/articles/PMC5203879/ /pubmed/28078285 http://dx.doi.org/10.1155/2016/2793898 Text en |
spellingShingle | Research Article Chen, Shaoqi Wang, Yukai Zhang, Guohong Chen, Shigao Combination of Salivary Gland Ultrasonography and Virtual Touch Quantification for Diagnosis of Sjögren's Syndrome: A Preliminary Study |
title | Combination of Salivary Gland Ultrasonography and Virtual Touch Quantification for Diagnosis of Sjögren's Syndrome: A Preliminary Study |
title_full | Combination of Salivary Gland Ultrasonography and Virtual Touch Quantification for Diagnosis of Sjögren's Syndrome: A Preliminary Study |
title_fullStr | Combination of Salivary Gland Ultrasonography and Virtual Touch Quantification for Diagnosis of Sjögren's Syndrome: A Preliminary Study |
title_full_unstemmed | Combination of Salivary Gland Ultrasonography and Virtual Touch Quantification for Diagnosis of Sjögren's Syndrome: A Preliminary Study |
title_short | Combination of Salivary Gland Ultrasonography and Virtual Touch Quantification for Diagnosis of Sjögren's Syndrome: A Preliminary Study |
title_sort | combination of salivary gland ultrasonography and virtual touch quantification for diagnosis of sjögren's syndrome: a preliminary study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5203879/ https://www.ncbi.nlm.nih.gov/pubmed/28078285 http://dx.doi.org/10.1155/2016/2793898 |
work_keys_str_mv | AT chenshaoqi combinationofsalivaryglandultrasonographyandvirtualtouchquantificationfordiagnosisofsjogrenssyndromeapreliminarystudy AT wangyukai combinationofsalivaryglandultrasonographyandvirtualtouchquantificationfordiagnosisofsjogrenssyndromeapreliminarystudy AT zhangguohong combinationofsalivaryglandultrasonographyandvirtualtouchquantificationfordiagnosisofsjogrenssyndromeapreliminarystudy AT chenshigao combinationofsalivaryglandultrasonographyandvirtualtouchquantificationfordiagnosisofsjogrenssyndromeapreliminarystudy |