Cargando…

The Value of the Model and Quantitative Parameters of Contrast-Enhanced Ultrasound in Judging the Severity of SHPT

Using the model and quantitative parameters of contrast-enhanced ultrasound (CEUS) to assess the severity of secondary hyperparathyroidism (SHPT) was proposed. 42 SHPT patients who underwent CEUS examination were divided into three groups, light, moderate, and heavy as per parathyroid hormone (PTH)....

Descripción completa

Detalles Bibliográficos
Autores principales: Liang, Xing-xin, Li, Fan, Gao, Feng, Liu, Yang, Qiao, Xiao-hui, Zhang, Zheng, Du, Lian-fang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi Publishing Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5204084/
https://www.ncbi.nlm.nih.gov/pubmed/28078296
http://dx.doi.org/10.1155/2016/6064526
_version_ 1782489840794730496
author Liang, Xing-xin
Li, Fan
Gao, Feng
Liu, Yang
Qiao, Xiao-hui
Zhang, Zheng
Du, Lian-fang
author_facet Liang, Xing-xin
Li, Fan
Gao, Feng
Liu, Yang
Qiao, Xiao-hui
Zhang, Zheng
Du, Lian-fang
author_sort Liang, Xing-xin
collection PubMed
description Using the model and quantitative parameters of contrast-enhanced ultrasound (CEUS) to assess the severity of secondary hyperparathyroidism (SHPT) was proposed. 42 SHPT patients who underwent CEUS examination were divided into three groups, light, moderate, and heavy as per parathyroid hormone (PTH). The process of CEUS was divided into two phases, wash-in phase and wash-out phase. The three groups were analyzed with their enhancing model in the two phases. The quantitative parameters of CEUS such as Arrival Time (AT), Time to Peak (TTP), Mean Transit Time (MTT), and Maximum Intensity (IMAX) were measured by time-intensity curve (TIC) and compared among the three groups. The enhancing model of light SHPT, moderate SHPT, and heavy SHPT showed statistical significance in wash-in phase and wash-out phase (P < 0.05). No difference was observed in AT and TTP among the three groups (P > 0.05) while MTT and IMAX showed statistical significance (P < 0.05). The CEUS of light SHPT was characterized by “slow-in, fast-out, and lower-enhancement” with short enhancement time; the CEUS of moderate SHPT was characterized by “fast-in, fast-out, and higher-enhancement” with slightly long enhancement time; the CEUS of heavy SHPT was characterized by “fast-in, slow-out, and higher-enhancement” with long enhancement time. Therefore, the model and quantitative parameters of CEUS can be benefit for the assessment of the severity of SHPT.
format Online
Article
Text
id pubmed-5204084
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Hindawi Publishing Corporation
record_format MEDLINE/PubMed
spelling pubmed-52040842017-01-11 The Value of the Model and Quantitative Parameters of Contrast-Enhanced Ultrasound in Judging the Severity of SHPT Liang, Xing-xin Li, Fan Gao, Feng Liu, Yang Qiao, Xiao-hui Zhang, Zheng Du, Lian-fang Biomed Res Int Research Article Using the model and quantitative parameters of contrast-enhanced ultrasound (CEUS) to assess the severity of secondary hyperparathyroidism (SHPT) was proposed. 42 SHPT patients who underwent CEUS examination were divided into three groups, light, moderate, and heavy as per parathyroid hormone (PTH). The process of CEUS was divided into two phases, wash-in phase and wash-out phase. The three groups were analyzed with their enhancing model in the two phases. The quantitative parameters of CEUS such as Arrival Time (AT), Time to Peak (TTP), Mean Transit Time (MTT), and Maximum Intensity (IMAX) were measured by time-intensity curve (TIC) and compared among the three groups. The enhancing model of light SHPT, moderate SHPT, and heavy SHPT showed statistical significance in wash-in phase and wash-out phase (P < 0.05). No difference was observed in AT and TTP among the three groups (P > 0.05) while MTT and IMAX showed statistical significance (P < 0.05). The CEUS of light SHPT was characterized by “slow-in, fast-out, and lower-enhancement” with short enhancement time; the CEUS of moderate SHPT was characterized by “fast-in, fast-out, and higher-enhancement” with slightly long enhancement time; the CEUS of heavy SHPT was characterized by “fast-in, slow-out, and higher-enhancement” with long enhancement time. Therefore, the model and quantitative parameters of CEUS can be benefit for the assessment of the severity of SHPT. Hindawi Publishing Corporation 2016 2016-12-19 /pmc/articles/PMC5204084/ /pubmed/28078296 http://dx.doi.org/10.1155/2016/6064526 Text en
spellingShingle Research Article
Liang, Xing-xin
Li, Fan
Gao, Feng
Liu, Yang
Qiao, Xiao-hui
Zhang, Zheng
Du, Lian-fang
The Value of the Model and Quantitative Parameters of Contrast-Enhanced Ultrasound in Judging the Severity of SHPT
title The Value of the Model and Quantitative Parameters of Contrast-Enhanced Ultrasound in Judging the Severity of SHPT
title_full The Value of the Model and Quantitative Parameters of Contrast-Enhanced Ultrasound in Judging the Severity of SHPT
title_fullStr The Value of the Model and Quantitative Parameters of Contrast-Enhanced Ultrasound in Judging the Severity of SHPT
title_full_unstemmed The Value of the Model and Quantitative Parameters of Contrast-Enhanced Ultrasound in Judging the Severity of SHPT
title_short The Value of the Model and Quantitative Parameters of Contrast-Enhanced Ultrasound in Judging the Severity of SHPT
title_sort value of the model and quantitative parameters of contrast-enhanced ultrasound in judging the severity of shpt
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5204084/
https://www.ncbi.nlm.nih.gov/pubmed/28078296
http://dx.doi.org/10.1155/2016/6064526
work_keys_str_mv AT liangxingxin thevalueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT lifan thevalueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT gaofeng thevalueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT liuyang thevalueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT qiaoxiaohui thevalueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT zhangzheng thevalueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT dulianfang thevalueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT liangxingxin valueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT lifan valueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT gaofeng valueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT liuyang valueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT qiaoxiaohui valueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT zhangzheng valueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt
AT dulianfang valueofthemodelandquantitativeparametersofcontrastenhancedultrasoundinjudgingtheseverityofshpt