Cargando…
Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method
PURPOSE: The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands. METHODS: Volume measurements for 40 parathyroid glands wer...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Korean Society of Ultrasound in Medicine
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5207356/ https://www.ncbi.nlm.nih.gov/pubmed/27457337 http://dx.doi.org/10.14366/usg.16022 |
_version_ | 1782490349152763904 |
---|---|
author | You, Sung-Hye Suh, Sang-il Ryoo, In-Seon Son, Gyu-Ri Lee, Young-Hen Seo, Hyung Suk Lee, Nam Joon Seol, Hae Young |
author_facet | You, Sung-Hye Suh, Sang-il Ryoo, In-Seon Son, Gyu-Ri Lee, Young-Hen Seo, Hyung Suk Lee, Nam Joon Seol, Hae Young |
author_sort | You, Sung-Hye |
collection | PubMed |
description | PURPOSE: The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands. METHODS: Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D) and three-dimensional (3D) methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs) and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. RESULTS: The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. CONCLUSION: The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism. |
format | Online Article Text |
id | pubmed-5207356 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Korean Society of Ultrasound in Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-52073562017-01-04 Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method You, Sung-Hye Suh, Sang-il Ryoo, In-Seon Son, Gyu-Ri Lee, Young-Hen Seo, Hyung Suk Lee, Nam Joon Seol, Hae Young Ultrasonography Original Article PURPOSE: The purpose of this study was to investigate the accuracy and reliability of the semi-automated ultrasonographic volume measurement tool, virtual organ computer-aided analysis (VOCAL), for measuring the volume of parathyroid glands. METHODS: Volume measurements for 40 parathyroid glands were performed in patients with secondary hyperparathyroidism caused by chronic renal failure. The volume of the parathyroid glands was measured twice by experienced radiologists by two-dimensional (2D) and three-dimensional (3D) methods using conventional sonograms and the VOCAL with 30°angle increments before parathyroidectomy. The specimen volume was also measured postoperatively. Intraclass correlation coefficients (ICCs) and the absolute percentage error were used for estimating the reproducibility and accuracy of the two different methods. RESULTS: The ICC value between two measurements of the 2D method and the 3D method was 0.956 and 0.999, respectively. The mean absolute percentage error of the 2D method and the 3D VOCAL technique was 29.56% and 5.78%, respectively. For accuracy and reliability, the plots of the 3D method showed a more compact distribution than those of the 2D method on the Bland-Altman graph. CONCLUSION: The rotational VOCAL method for measuring the parathyroid gland is more accurate and reliable than the conventional 2D measurement. This VOCAL method could be used as a more reliable follow-up imaging modality in a patient with hyperparathyroidism. Korean Society of Ultrasound in Medicine 2017-01 2016-06-08 /pmc/articles/PMC5207356/ /pubmed/27457337 http://dx.doi.org/10.14366/usg.16022 Text en Copyright © 2017 Korean Society of Ultrasound in Medicine (KSUM) This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article You, Sung-Hye Suh, Sang-il Ryoo, In-Seon Son, Gyu-Ri Lee, Young-Hen Seo, Hyung Suk Lee, Nam Joon Seol, Hae Young Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method |
title | Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method |
title_full | Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method |
title_fullStr | Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method |
title_full_unstemmed | Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method |
title_short | Assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method |
title_sort | assessing the accuracy and reliability of ultrasonographic three-dimensional parathyroid volume measurement in a patient with secondary hyperparathyroidism: a comparison with the two-dimensional conventional method |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5207356/ https://www.ncbi.nlm.nih.gov/pubmed/27457337 http://dx.doi.org/10.14366/usg.16022 |
work_keys_str_mv | AT yousunghye assessingtheaccuracyandreliabilityofultrasonographicthreedimensionalparathyroidvolumemeasurementinapatientwithsecondaryhyperparathyroidismacomparisonwiththetwodimensionalconventionalmethod AT suhsangil assessingtheaccuracyandreliabilityofultrasonographicthreedimensionalparathyroidvolumemeasurementinapatientwithsecondaryhyperparathyroidismacomparisonwiththetwodimensionalconventionalmethod AT ryooinseon assessingtheaccuracyandreliabilityofultrasonographicthreedimensionalparathyroidvolumemeasurementinapatientwithsecondaryhyperparathyroidismacomparisonwiththetwodimensionalconventionalmethod AT songyuri assessingtheaccuracyandreliabilityofultrasonographicthreedimensionalparathyroidvolumemeasurementinapatientwithsecondaryhyperparathyroidismacomparisonwiththetwodimensionalconventionalmethod AT leeyounghen assessingtheaccuracyandreliabilityofultrasonographicthreedimensionalparathyroidvolumemeasurementinapatientwithsecondaryhyperparathyroidismacomparisonwiththetwodimensionalconventionalmethod AT seohyungsuk assessingtheaccuracyandreliabilityofultrasonographicthreedimensionalparathyroidvolumemeasurementinapatientwithsecondaryhyperparathyroidismacomparisonwiththetwodimensionalconventionalmethod AT leenamjoon assessingtheaccuracyandreliabilityofultrasonographicthreedimensionalparathyroidvolumemeasurementinapatientwithsecondaryhyperparathyroidismacomparisonwiththetwodimensionalconventionalmethod AT seolhaeyoung assessingtheaccuracyandreliabilityofultrasonographicthreedimensionalparathyroidvolumemeasurementinapatientwithsecondaryhyperparathyroidismacomparisonwiththetwodimensionalconventionalmethod |