Cargando…

Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery

PURPOSE: To evaluate the effects of diquafosol sodium ophthalmic solution 3% (DQS) and artificial tears (AT) on higher-order aberrations (HOAs) in patients with dry eye after cataract surgery. DESIGN: This was a post hoc analysis of a previously conducted randomized clinical study. METHODS: Fifty-ni...

Descripción completa

Detalles Bibliográficos
Autores principales: Inoue, Yasushi, Ochi, Shintarou
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5207435/
https://www.ncbi.nlm.nih.gov/pubmed/28096651
http://dx.doi.org/10.2147/OPTH.S122542
_version_ 1782490360949243904
author Inoue, Yasushi
Ochi, Shintarou
author_facet Inoue, Yasushi
Ochi, Shintarou
author_sort Inoue, Yasushi
collection PubMed
description PURPOSE: To evaluate the effects of diquafosol sodium ophthalmic solution 3% (DQS) and artificial tears (AT) on higher-order aberrations (HOAs) in patients with dry eye after cataract surgery. DESIGN: This was a post hoc analysis of a previously conducted randomized clinical study. METHODS: Fifty-nine eyes from 42 patients (17 males and 25 females, aged 72.6±8.0 years) with verified or suspected dry eye at 4 weeks after cataract surgery were evaluated. The dry eye patients were randomly assigned to receive DQS or AT for 4 weeks. Tear breakup time (BUT), corneal and conjunctival fluorescein staining scores, and HOAs were analyzed before and after instillation. HOAs were measured consecutively for 10 seconds with a wavefront analyzer. Average HOAs, HOA fluctuations (fluctuation index [FI]) and changes in HOAs (stability index [SI]) were compared within and between the two groups. RESULTS: After 4 weeks of instillation, BUT significantly increased (P=0.001) compared with preinstillation values in the DQS group, but not in the AT group. This increase in BUT in the DQS group was significantly greater than in the AT group (P=0.014). Corneal and conjunctival fluorescein staining scores after instillation significantly improved compared with preinstillation values in the DQS group (P=0.018). In HOAs, the cornea aberration changed from an upward curve (a sawtooth pattern) to an almost constant value (a stable pattern) in the DQS group, but not in the AT group. In FI and SI, there were no significant changes in either group; however, FI and SI were significantly lower in the DQS group than in the AT group (both, P=0.004). CONCLUSION: The dry eye patients after cataract surgery had a visual dysfunction in HOAs. DQS is effective to treat dry eye disease after cataract surgery with improvement of visual function.
format Online
Article
Text
id pubmed-5207435
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-52074352017-01-17 Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery Inoue, Yasushi Ochi, Shintarou Clin Ophthalmol Original Research PURPOSE: To evaluate the effects of diquafosol sodium ophthalmic solution 3% (DQS) and artificial tears (AT) on higher-order aberrations (HOAs) in patients with dry eye after cataract surgery. DESIGN: This was a post hoc analysis of a previously conducted randomized clinical study. METHODS: Fifty-nine eyes from 42 patients (17 males and 25 females, aged 72.6±8.0 years) with verified or suspected dry eye at 4 weeks after cataract surgery were evaluated. The dry eye patients were randomly assigned to receive DQS or AT for 4 weeks. Tear breakup time (BUT), corneal and conjunctival fluorescein staining scores, and HOAs were analyzed before and after instillation. HOAs were measured consecutively for 10 seconds with a wavefront analyzer. Average HOAs, HOA fluctuations (fluctuation index [FI]) and changes in HOAs (stability index [SI]) were compared within and between the two groups. RESULTS: After 4 weeks of instillation, BUT significantly increased (P=0.001) compared with preinstillation values in the DQS group, but not in the AT group. This increase in BUT in the DQS group was significantly greater than in the AT group (P=0.014). Corneal and conjunctival fluorescein staining scores after instillation significantly improved compared with preinstillation values in the DQS group (P=0.018). In HOAs, the cornea aberration changed from an upward curve (a sawtooth pattern) to an almost constant value (a stable pattern) in the DQS group, but not in the AT group. In FI and SI, there were no significant changes in either group; however, FI and SI were significantly lower in the DQS group than in the AT group (both, P=0.004). CONCLUSION: The dry eye patients after cataract surgery had a visual dysfunction in HOAs. DQS is effective to treat dry eye disease after cataract surgery with improvement of visual function. Dove Medical Press 2016-12-23 /pmc/articles/PMC5207435/ /pubmed/28096651 http://dx.doi.org/10.2147/OPTH.S122542 Text en © 2017 Inoue and Ochi. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Inoue, Yasushi
Ochi, Shintarou
Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery
title Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery
title_full Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery
title_fullStr Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery
title_full_unstemmed Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery
title_short Effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery
title_sort effects of 3% diquafosol sodium ophthalmic solution on higher-order aberrations in patients diagnosed with dry eye after cataract surgery
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5207435/
https://www.ncbi.nlm.nih.gov/pubmed/28096651
http://dx.doi.org/10.2147/OPTH.S122542
work_keys_str_mv AT inoueyasushi effectsof3diquafosolsodiumophthalmicsolutiononhigherorderaberrationsinpatientsdiagnosedwithdryeyeaftercataractsurgery
AT ochishintarou effectsof3diquafosolsodiumophthalmicsolutiononhigherorderaberrationsinpatientsdiagnosedwithdryeyeaftercataractsurgery