Cargando…

Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up

PURPOSE: We attempted to evaluate the efficacy of femtosecond laser-assisted intrastromal corneal ring segment implantation in patients with keratoconus (KC). PATIENTS AND METHODS: A retrospective interventional consecutive clinical study was conducted on patients with KC who were treated with femto...

Descripción completa

Detalles Bibliográficos
Autores principales: Heikal, Mohamed A, Abdelshafy, Marwa, Soliman, Tarek T, Hamed, Abdelmonem M
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5207472/
https://www.ncbi.nlm.nih.gov/pubmed/28096650
http://dx.doi.org/10.2147/OPTH.S120267
_version_ 1782490369181614080
author Heikal, Mohamed A
Abdelshafy, Marwa
Soliman, Tarek T
Hamed, Abdelmonem M
author_facet Heikal, Mohamed A
Abdelshafy, Marwa
Soliman, Tarek T
Hamed, Abdelmonem M
author_sort Heikal, Mohamed A
collection PubMed
description PURPOSE: We attempted to evaluate the efficacy of femtosecond laser-assisted intrastromal corneal ring segment implantation in patients with keratoconus (KC). PATIENTS AND METHODS: A retrospective interventional consecutive clinical study was conducted on patients with KC who were treated with femtosecond laser Keraring implantation. All procedures were performed at Ebsar Eye Center in the period from January 5, 2015, to February 28, 2016. RESULTS: Thirty eyes of 20 patients were included in this study. The mean age of patients was 27.43±3.57 years. Eleven patients (55%) were female and nine patients (45%) were male. Keraring segments were successfully implanted in all eyes. There were no complications or need for ring repositioning. The follow-up period was 6 months postoperatively. There was a significant improvement in the mean logarithm of the minimum angle of resolution (LogMAR) of uncorrected visual acuity (UCVA) after Keraring segment implantation from 1.5±0.23 preoperatively to 0.54±0.16 at 6 months postoperatively (P=0.001). The preoperative mean LogMAR of best-corrected visual acuity (BCVA) was 0.85±0.17. At 1 month postoperatively, it was 0.35±0.15; at 3 months postoperatively, it was 0.26±0.11, and at 6 months postoperatively, it was 0.14±0.07 (P=0.001). The mean preoperative maximum keratometric value for 3 mm pupil in diopters (K max) significantly decreased from 55.85±5.44 preoperatively (N=30) to 44.05±1.64 D at 6 months postoperatively (P=0.001). There was a statistically significant reduction in the mean preoperative spherical equivalent from −5.43±1.76 D preoperatively to −2.43±0.95 D at 6 months postoperatively. No statistically significant differences were detected between 1 and 3 months of follow-up regarding the visual and refractive outcomes. CONCLUSION: Analysis of the outcomes after Keraring ICRS implantation showed a significant postoperative corneal flattening with a subsequent increase in UCVA and BCVA. Using the femtosecond laser for tunnel creation made the procedure easy and fast with an accurate precise depth of implantation and reduced the risk of operative and postoperative complications.
format Online
Article
Text
id pubmed-5207472
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-52074722017-01-17 Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up Heikal, Mohamed A Abdelshafy, Marwa Soliman, Tarek T Hamed, Abdelmonem M Clin Ophthalmol Original Research PURPOSE: We attempted to evaluate the efficacy of femtosecond laser-assisted intrastromal corneal ring segment implantation in patients with keratoconus (KC). PATIENTS AND METHODS: A retrospective interventional consecutive clinical study was conducted on patients with KC who were treated with femtosecond laser Keraring implantation. All procedures were performed at Ebsar Eye Center in the period from January 5, 2015, to February 28, 2016. RESULTS: Thirty eyes of 20 patients were included in this study. The mean age of patients was 27.43±3.57 years. Eleven patients (55%) were female and nine patients (45%) were male. Keraring segments were successfully implanted in all eyes. There were no complications or need for ring repositioning. The follow-up period was 6 months postoperatively. There was a significant improvement in the mean logarithm of the minimum angle of resolution (LogMAR) of uncorrected visual acuity (UCVA) after Keraring segment implantation from 1.5±0.23 preoperatively to 0.54±0.16 at 6 months postoperatively (P=0.001). The preoperative mean LogMAR of best-corrected visual acuity (BCVA) was 0.85±0.17. At 1 month postoperatively, it was 0.35±0.15; at 3 months postoperatively, it was 0.26±0.11, and at 6 months postoperatively, it was 0.14±0.07 (P=0.001). The mean preoperative maximum keratometric value for 3 mm pupil in diopters (K max) significantly decreased from 55.85±5.44 preoperatively (N=30) to 44.05±1.64 D at 6 months postoperatively (P=0.001). There was a statistically significant reduction in the mean preoperative spherical equivalent from −5.43±1.76 D preoperatively to −2.43±0.95 D at 6 months postoperatively. No statistically significant differences were detected between 1 and 3 months of follow-up regarding the visual and refractive outcomes. CONCLUSION: Analysis of the outcomes after Keraring ICRS implantation showed a significant postoperative corneal flattening with a subsequent increase in UCVA and BCVA. Using the femtosecond laser for tunnel creation made the procedure easy and fast with an accurate precise depth of implantation and reduced the risk of operative and postoperative complications. Dove Medical Press 2016-12-23 /pmc/articles/PMC5207472/ /pubmed/28096650 http://dx.doi.org/10.2147/OPTH.S120267 Text en © 2017 Heikal et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Heikal, Mohamed A
Abdelshafy, Marwa
Soliman, Tarek T
Hamed, Abdelmonem M
Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up
title Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up
title_full Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up
title_fullStr Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up
title_full_unstemmed Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up
title_short Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up
title_sort refractive and visual outcomes after keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5207472/
https://www.ncbi.nlm.nih.gov/pubmed/28096650
http://dx.doi.org/10.2147/OPTH.S120267
work_keys_str_mv AT heikalmohameda refractiveandvisualoutcomesafterkeraringintrastromalcornealringsegmentimplantationforkeratoconusassistedbyfemtosecondlaserat6monthsfollowup
AT abdelshafymarwa refractiveandvisualoutcomesafterkeraringintrastromalcornealringsegmentimplantationforkeratoconusassistedbyfemtosecondlaserat6monthsfollowup
AT solimantarekt refractiveandvisualoutcomesafterkeraringintrastromalcornealringsegmentimplantationforkeratoconusassistedbyfemtosecondlaserat6monthsfollowup
AT hamedabdelmonemm refractiveandvisualoutcomesafterkeraringintrastromalcornealringsegmentimplantationforkeratoconusassistedbyfemtosecondlaserat6monthsfollowup