Cargando…
Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up
PURPOSE: We attempted to evaluate the efficacy of femtosecond laser-assisted intrastromal corneal ring segment implantation in patients with keratoconus (KC). PATIENTS AND METHODS: A retrospective interventional consecutive clinical study was conducted on patients with KC who were treated with femto...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5207472/ https://www.ncbi.nlm.nih.gov/pubmed/28096650 http://dx.doi.org/10.2147/OPTH.S120267 |
_version_ | 1782490369181614080 |
---|---|
author | Heikal, Mohamed A Abdelshafy, Marwa Soliman, Tarek T Hamed, Abdelmonem M |
author_facet | Heikal, Mohamed A Abdelshafy, Marwa Soliman, Tarek T Hamed, Abdelmonem M |
author_sort | Heikal, Mohamed A |
collection | PubMed |
description | PURPOSE: We attempted to evaluate the efficacy of femtosecond laser-assisted intrastromal corneal ring segment implantation in patients with keratoconus (KC). PATIENTS AND METHODS: A retrospective interventional consecutive clinical study was conducted on patients with KC who were treated with femtosecond laser Keraring implantation. All procedures were performed at Ebsar Eye Center in the period from January 5, 2015, to February 28, 2016. RESULTS: Thirty eyes of 20 patients were included in this study. The mean age of patients was 27.43±3.57 years. Eleven patients (55%) were female and nine patients (45%) were male. Keraring segments were successfully implanted in all eyes. There were no complications or need for ring repositioning. The follow-up period was 6 months postoperatively. There was a significant improvement in the mean logarithm of the minimum angle of resolution (LogMAR) of uncorrected visual acuity (UCVA) after Keraring segment implantation from 1.5±0.23 preoperatively to 0.54±0.16 at 6 months postoperatively (P=0.001). The preoperative mean LogMAR of best-corrected visual acuity (BCVA) was 0.85±0.17. At 1 month postoperatively, it was 0.35±0.15; at 3 months postoperatively, it was 0.26±0.11, and at 6 months postoperatively, it was 0.14±0.07 (P=0.001). The mean preoperative maximum keratometric value for 3 mm pupil in diopters (K max) significantly decreased from 55.85±5.44 preoperatively (N=30) to 44.05±1.64 D at 6 months postoperatively (P=0.001). There was a statistically significant reduction in the mean preoperative spherical equivalent from −5.43±1.76 D preoperatively to −2.43±0.95 D at 6 months postoperatively. No statistically significant differences were detected between 1 and 3 months of follow-up regarding the visual and refractive outcomes. CONCLUSION: Analysis of the outcomes after Keraring ICRS implantation showed a significant postoperative corneal flattening with a subsequent increase in UCVA and BCVA. Using the femtosecond laser for tunnel creation made the procedure easy and fast with an accurate precise depth of implantation and reduced the risk of operative and postoperative complications. |
format | Online Article Text |
id | pubmed-5207472 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-52074722017-01-17 Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up Heikal, Mohamed A Abdelshafy, Marwa Soliman, Tarek T Hamed, Abdelmonem M Clin Ophthalmol Original Research PURPOSE: We attempted to evaluate the efficacy of femtosecond laser-assisted intrastromal corneal ring segment implantation in patients with keratoconus (KC). PATIENTS AND METHODS: A retrospective interventional consecutive clinical study was conducted on patients with KC who were treated with femtosecond laser Keraring implantation. All procedures were performed at Ebsar Eye Center in the period from January 5, 2015, to February 28, 2016. RESULTS: Thirty eyes of 20 patients were included in this study. The mean age of patients was 27.43±3.57 years. Eleven patients (55%) were female and nine patients (45%) were male. Keraring segments were successfully implanted in all eyes. There were no complications or need for ring repositioning. The follow-up period was 6 months postoperatively. There was a significant improvement in the mean logarithm of the minimum angle of resolution (LogMAR) of uncorrected visual acuity (UCVA) after Keraring segment implantation from 1.5±0.23 preoperatively to 0.54±0.16 at 6 months postoperatively (P=0.001). The preoperative mean LogMAR of best-corrected visual acuity (BCVA) was 0.85±0.17. At 1 month postoperatively, it was 0.35±0.15; at 3 months postoperatively, it was 0.26±0.11, and at 6 months postoperatively, it was 0.14±0.07 (P=0.001). The mean preoperative maximum keratometric value for 3 mm pupil in diopters (K max) significantly decreased from 55.85±5.44 preoperatively (N=30) to 44.05±1.64 D at 6 months postoperatively (P=0.001). There was a statistically significant reduction in the mean preoperative spherical equivalent from −5.43±1.76 D preoperatively to −2.43±0.95 D at 6 months postoperatively. No statistically significant differences were detected between 1 and 3 months of follow-up regarding the visual and refractive outcomes. CONCLUSION: Analysis of the outcomes after Keraring ICRS implantation showed a significant postoperative corneal flattening with a subsequent increase in UCVA and BCVA. Using the femtosecond laser for tunnel creation made the procedure easy and fast with an accurate precise depth of implantation and reduced the risk of operative and postoperative complications. Dove Medical Press 2016-12-23 /pmc/articles/PMC5207472/ /pubmed/28096650 http://dx.doi.org/10.2147/OPTH.S120267 Text en © 2017 Heikal et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Heikal, Mohamed A Abdelshafy, Marwa Soliman, Tarek T Hamed, Abdelmonem M Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up |
title | Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up |
title_full | Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up |
title_fullStr | Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up |
title_full_unstemmed | Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up |
title_short | Refractive and visual outcomes after Keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up |
title_sort | refractive and visual outcomes after keraring intrastromal corneal ring segment implantation for keratoconus assisted by femtosecond laser at 6 months follow-up |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5207472/ https://www.ncbi.nlm.nih.gov/pubmed/28096650 http://dx.doi.org/10.2147/OPTH.S120267 |
work_keys_str_mv | AT heikalmohameda refractiveandvisualoutcomesafterkeraringintrastromalcornealringsegmentimplantationforkeratoconusassistedbyfemtosecondlaserat6monthsfollowup AT abdelshafymarwa refractiveandvisualoutcomesafterkeraringintrastromalcornealringsegmentimplantationforkeratoconusassistedbyfemtosecondlaserat6monthsfollowup AT solimantarekt refractiveandvisualoutcomesafterkeraringintrastromalcornealringsegmentimplantationforkeratoconusassistedbyfemtosecondlaserat6monthsfollowup AT hamedabdelmonemm refractiveandvisualoutcomesafterkeraringintrastromalcornealringsegmentimplantationforkeratoconusassistedbyfemtosecondlaserat6monthsfollowup |