Cargando…

Three-Dimensional High-Frequency Ultrasonography for Early Detection and Characterization of Embryo Implantation Site Development in the Mouse

Ultrasonography is a powerful tool to non-invasively monitor in real time the development of the human fetus in utero. Although genetically engineered mice have served as valuable in vivo models to study both embryo implantation and pregnancy progression, such studies usually require sacrifice of pa...

Descripción completa

Detalles Bibliográficos
Autores principales: Peavey, Mary C., Reynolds, Corey L., Szwarc, Maria M., Gibbons, William E., Valdes, Cecilia T., DeMayo, Francesco J., Lydon, John P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5207679/
https://www.ncbi.nlm.nih.gov/pubmed/28046063
http://dx.doi.org/10.1371/journal.pone.0169312
_version_ 1782490411722342400
author Peavey, Mary C.
Reynolds, Corey L.
Szwarc, Maria M.
Gibbons, William E.
Valdes, Cecilia T.
DeMayo, Francesco J.
Lydon, John P.
author_facet Peavey, Mary C.
Reynolds, Corey L.
Szwarc, Maria M.
Gibbons, William E.
Valdes, Cecilia T.
DeMayo, Francesco J.
Lydon, John P.
author_sort Peavey, Mary C.
collection PubMed
description Ultrasonography is a powerful tool to non-invasively monitor in real time the development of the human fetus in utero. Although genetically engineered mice have served as valuable in vivo models to study both embryo implantation and pregnancy progression, such studies usually require sacrifice of parous mice for subsequent phenotypic analysis. To address this issue, we used three-dimensional (3-D) reconstruction in silico of high-frequency ultrasound (HFUS) imaging data for early detection and characterization of murine embryo implantation sites and their development in utero. With HFUS imaging followed by 3-D reconstruction, we were able to precisely quantify embryo implantation site number and embryonic developmental progression in pregnant C57BL6J/129S mice from as early as 5.5 days post coitus (d.p.c.) through to 9.5 d.p.c. using a VisualSonics Vevo 2100 (MS550S) transducer. In addition to measurements of implantation site number, location, volume and spacing, embryo viability via cardiac activity monitoring was also achieved. A total of 12 dams were imaged with HFUS with approximately 100 embryos examined per embryonic day. For the post-implantation period (5.5 to 8.5 d.p.c.), 3-D reconstruction of the gravid uterus in mesh or solid overlay format enabled visual representation in silico of implantation site location, number, spacing distances, and site volume within each uterine horn. Therefore, this short technical report describes the feasibility of using 3-D HFUS imaging for early detection and analysis of post-implantation events in the pregnant mouse with the ability to longitudinally monitor the development of these early pregnancy events in a non-invasive manner. As genetically engineered mice continue to be used to characterize female reproductive phenotypes, we believe this reliable and non-invasive method to detect, quantify, and characterize early implantation events will prove to be an invaluable investigative tool for the study of female infertility and subfertility phenotypes based on a defective uterus.
format Online
Article
Text
id pubmed-5207679
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-52076792017-01-19 Three-Dimensional High-Frequency Ultrasonography for Early Detection and Characterization of Embryo Implantation Site Development in the Mouse Peavey, Mary C. Reynolds, Corey L. Szwarc, Maria M. Gibbons, William E. Valdes, Cecilia T. DeMayo, Francesco J. Lydon, John P. PLoS One Research Article Ultrasonography is a powerful tool to non-invasively monitor in real time the development of the human fetus in utero. Although genetically engineered mice have served as valuable in vivo models to study both embryo implantation and pregnancy progression, such studies usually require sacrifice of parous mice for subsequent phenotypic analysis. To address this issue, we used three-dimensional (3-D) reconstruction in silico of high-frequency ultrasound (HFUS) imaging data for early detection and characterization of murine embryo implantation sites and their development in utero. With HFUS imaging followed by 3-D reconstruction, we were able to precisely quantify embryo implantation site number and embryonic developmental progression in pregnant C57BL6J/129S mice from as early as 5.5 days post coitus (d.p.c.) through to 9.5 d.p.c. using a VisualSonics Vevo 2100 (MS550S) transducer. In addition to measurements of implantation site number, location, volume and spacing, embryo viability via cardiac activity monitoring was also achieved. A total of 12 dams were imaged with HFUS with approximately 100 embryos examined per embryonic day. For the post-implantation period (5.5 to 8.5 d.p.c.), 3-D reconstruction of the gravid uterus in mesh or solid overlay format enabled visual representation in silico of implantation site location, number, spacing distances, and site volume within each uterine horn. Therefore, this short technical report describes the feasibility of using 3-D HFUS imaging for early detection and analysis of post-implantation events in the pregnant mouse with the ability to longitudinally monitor the development of these early pregnancy events in a non-invasive manner. As genetically engineered mice continue to be used to characterize female reproductive phenotypes, we believe this reliable and non-invasive method to detect, quantify, and characterize early implantation events will prove to be an invaluable investigative tool for the study of female infertility and subfertility phenotypes based on a defective uterus. Public Library of Science 2017-01-03 /pmc/articles/PMC5207679/ /pubmed/28046063 http://dx.doi.org/10.1371/journal.pone.0169312 Text en https://creativecommons.org/publicdomain/zero/1.0/ This is an open access article, free of all copyright, and may be freely reproduced, distributed, transmitted, modified, built upon, or otherwise used by anyone for any lawful purpose. The work is made available under the Creative Commons CC0 (https://creativecommons.org/publicdomain/zero/1.0/) public domain dedication.
spellingShingle Research Article
Peavey, Mary C.
Reynolds, Corey L.
Szwarc, Maria M.
Gibbons, William E.
Valdes, Cecilia T.
DeMayo, Francesco J.
Lydon, John P.
Three-Dimensional High-Frequency Ultrasonography for Early Detection and Characterization of Embryo Implantation Site Development in the Mouse
title Three-Dimensional High-Frequency Ultrasonography for Early Detection and Characterization of Embryo Implantation Site Development in the Mouse
title_full Three-Dimensional High-Frequency Ultrasonography for Early Detection and Characterization of Embryo Implantation Site Development in the Mouse
title_fullStr Three-Dimensional High-Frequency Ultrasonography for Early Detection and Characterization of Embryo Implantation Site Development in the Mouse
title_full_unstemmed Three-Dimensional High-Frequency Ultrasonography for Early Detection and Characterization of Embryo Implantation Site Development in the Mouse
title_short Three-Dimensional High-Frequency Ultrasonography for Early Detection and Characterization of Embryo Implantation Site Development in the Mouse
title_sort three-dimensional high-frequency ultrasonography for early detection and characterization of embryo implantation site development in the mouse
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5207679/
https://www.ncbi.nlm.nih.gov/pubmed/28046063
http://dx.doi.org/10.1371/journal.pone.0169312
work_keys_str_mv AT peaveymaryc threedimensionalhighfrequencyultrasonographyforearlydetectionandcharacterizationofembryoimplantationsitedevelopmentinthemouse
AT reynoldscoreyl threedimensionalhighfrequencyultrasonographyforearlydetectionandcharacterizationofembryoimplantationsitedevelopmentinthemouse
AT szwarcmariam threedimensionalhighfrequencyultrasonographyforearlydetectionandcharacterizationofembryoimplantationsitedevelopmentinthemouse
AT gibbonswilliame threedimensionalhighfrequencyultrasonographyforearlydetectionandcharacterizationofembryoimplantationsitedevelopmentinthemouse
AT valdesceciliat threedimensionalhighfrequencyultrasonographyforearlydetectionandcharacterizationofembryoimplantationsitedevelopmentinthemouse
AT demayofrancescoj threedimensionalhighfrequencyultrasonographyforearlydetectionandcharacterizationofembryoimplantationsitedevelopmentinthemouse
AT lydonjohnp threedimensionalhighfrequencyultrasonographyforearlydetectionandcharacterizationofembryoimplantationsitedevelopmentinthemouse