Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification
CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife proce...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5207685/ https://www.ncbi.nlm.nih.gov/pubmed/28046056 http://dx.doi.org/10.1371/journal.pone.0169252 |
_version_ | 1782490413019430912 |
---|---|
author | Hsu, Shih-Ming Hung, Chao-Hsiung Liao, Yi-Jen Fu, Hsiao-Mei Tsai, Jo-Ting Huang, Yung-Hui Huang, David Y. C. |
author_facet | Hsu, Shih-Ming Hung, Chao-Hsiung Liao, Yi-Jen Fu, Hsiao-Mei Tsai, Jo-Ting Huang, Yung-Hui Huang, David Y. C. |
author_sort | Hsu, Shih-Ming |
collection | PubMed |
description | CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife procedure and validate a viable dose verification system for CyberKnife treatment. A radiophotoluminescent glass dosimeter, thermoluminescent dosimeter, and Kodak EDR2 film were used to measure the lateral dose profile and percent depth dose of CyberKnife. A Monte Carlo simulation for dose verification was performed using BEAMnrc to verify the measured results. This study also used a radiophotoluminescent glass dosimeter coupled with an anthropomorphic phantom to evaluate the accuracy of the dose given by CyberKnife. Measurements from the radiophotoluminescent glass dosimeter were compared with the results of a thermoluminescent dosimeter and EDR2 film, and the differences found were less than 5%. The radiophotoluminescent glass dosimeter has some advantages in terms of dose measurements over CyberKnife, such as repeatability, stability, and small effective size. These advantages make radiophotoluminescent glass dosimeters a potential candidate dosimeter for the CyberKnife procedure. This study concludes that radiophotoluminescent glass dosimeters are a promising and reliable dosimeter for CyberKnife dose verification with clinically acceptable accuracy within 5%. |
format | Online Article Text |
id | pubmed-5207685 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-52076852017-01-19 Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification Hsu, Shih-Ming Hung, Chao-Hsiung Liao, Yi-Jen Fu, Hsiao-Mei Tsai, Jo-Ting Huang, Yung-Hui Huang, David Y. C. PLoS One Research Article CyberKnife is one of multiple modalities for stereotactic radiosurgery (SRS). Due to the nature of CyberKnife and the characteristics of SRS, dose evaluation of the CyberKnife procedure is critical. A radiophotoluminescent glass dosimeter was used to verify the dose accuracy for the CyberKnife procedure and validate a viable dose verification system for CyberKnife treatment. A radiophotoluminescent glass dosimeter, thermoluminescent dosimeter, and Kodak EDR2 film were used to measure the lateral dose profile and percent depth dose of CyberKnife. A Monte Carlo simulation for dose verification was performed using BEAMnrc to verify the measured results. This study also used a radiophotoluminescent glass dosimeter coupled with an anthropomorphic phantom to evaluate the accuracy of the dose given by CyberKnife. Measurements from the radiophotoluminescent glass dosimeter were compared with the results of a thermoluminescent dosimeter and EDR2 film, and the differences found were less than 5%. The radiophotoluminescent glass dosimeter has some advantages in terms of dose measurements over CyberKnife, such as repeatability, stability, and small effective size. These advantages make radiophotoluminescent glass dosimeters a potential candidate dosimeter for the CyberKnife procedure. This study concludes that radiophotoluminescent glass dosimeters are a promising and reliable dosimeter for CyberKnife dose verification with clinically acceptable accuracy within 5%. Public Library of Science 2017-01-03 /pmc/articles/PMC5207685/ /pubmed/28046056 http://dx.doi.org/10.1371/journal.pone.0169252 Text en © 2017 Hsu et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Hsu, Shih-Ming Hung, Chao-Hsiung Liao, Yi-Jen Fu, Hsiao-Mei Tsai, Jo-Ting Huang, Yung-Hui Huang, David Y. C. Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification |
title | Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification |
title_full | Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification |
title_fullStr | Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification |
title_full_unstemmed | Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification |
title_short | Feasibility Study on Applying Radiophotoluminescent Glass Dosimeters for CyberKnife SRS Dose Verification |
title_sort | feasibility study on applying radiophotoluminescent glass dosimeters for cyberknife srs dose verification |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5207685/ https://www.ncbi.nlm.nih.gov/pubmed/28046056 http://dx.doi.org/10.1371/journal.pone.0169252 |
work_keys_str_mv | AT hsushihming feasibilitystudyonapplyingradiophotoluminescentglassdosimetersforcyberknifesrsdoseverification AT hungchaohsiung feasibilitystudyonapplyingradiophotoluminescentglassdosimetersforcyberknifesrsdoseverification AT liaoyijen feasibilitystudyonapplyingradiophotoluminescentglassdosimetersforcyberknifesrsdoseverification AT fuhsiaomei feasibilitystudyonapplyingradiophotoluminescentglassdosimetersforcyberknifesrsdoseverification AT tsaijoting feasibilitystudyonapplyingradiophotoluminescentglassdosimetersforcyberknifesrsdoseverification AT huangyunghui feasibilitystudyonapplyingradiophotoluminescentglassdosimetersforcyberknifesrsdoseverification AT huangdavidyc feasibilitystudyonapplyingradiophotoluminescentglassdosimetersforcyberknifesrsdoseverification |