Cargando…

Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study

OBJECTIVES: To evaluate the potential value of advanced monoenergetic images (AMEIs) on early gastric cancer (EGC) using dual-energy CT (DECT). METHODS: 31 EGC patients (19 men, 12 women; age range, 38–81 years; mean age, 57.19 years) were retrospectively enrolled in this study. Conventionally recon...

Descripción completa

Detalles Bibliográficos
Autores principales: Shi, Cen, Zhang, Huan, Yan, Jing, Wang, Baisong, Du, Lianjun, Pan, Zilai, Yan, Fuhua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5209438/
https://www.ncbi.nlm.nih.gov/pubmed/27271924
http://dx.doi.org/10.1007/s00330-016-4442-z
_version_ 1782490742557507584
author Shi, Cen
Zhang, Huan
Yan, Jing
Wang, Baisong
Du, Lianjun
Pan, Zilai
Yan, Fuhua
author_facet Shi, Cen
Zhang, Huan
Yan, Jing
Wang, Baisong
Du, Lianjun
Pan, Zilai
Yan, Fuhua
author_sort Shi, Cen
collection PubMed
description OBJECTIVES: To evaluate the potential value of advanced monoenergetic images (AMEIs) on early gastric cancer (EGC) using dual-energy CT (DECT). METHODS: 31 EGC patients (19 men, 12 women; age range, 38–81 years; mean age, 57.19 years) were retrospectively enrolled in this study. Conventionally reconstructed polyenergetic images (PEIs) at 120 kV and virtual monoenergetic images (MEIs) and AMEIs at six different kiloelectron volt (keV) levels (from 40 to 90 keV) were evaluated from the 100 and Sn 140 kV dual energy image data, respectively. The visibility and stage migration of EGC for all three image data sets were evaluated and statistically analyzed. The objective and subjective image qualities were also evaluated. RESULTS: AMEIs at 40 keV showed the best visibility (80.7 %) and the lowest stage migration (35.5 %) for EGC. The stage migration for AMEIs at 40 keV was significantly lower than that for PEIs (p = 0.026). AMEIs at 40 keV had statistically higher CNR in the arterial and portal phases, gastric-specific diagnostic performance and visual sharpness compared with other AMEIs, MEIs and PEIs (all p < 0.05). CONCLUSIONS: AMEIs at 40 keV with MPR increase the CNR of EGC and thus potentially lower the stage migration of EGC. KEY POINTS: • AMEIs benefits from the recombination of low-keV images and medium energies. • AMEIs could receive better CNR results than MEIs. • AMEIs at 40 keV potentially lower the stage migration of EGC. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00330-016-4442-z) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5209438
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-52094382017-01-18 Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study Shi, Cen Zhang, Huan Yan, Jing Wang, Baisong Du, Lianjun Pan, Zilai Yan, Fuhua Eur Radiol Computed Tomography OBJECTIVES: To evaluate the potential value of advanced monoenergetic images (AMEIs) on early gastric cancer (EGC) using dual-energy CT (DECT). METHODS: 31 EGC patients (19 men, 12 women; age range, 38–81 years; mean age, 57.19 years) were retrospectively enrolled in this study. Conventionally reconstructed polyenergetic images (PEIs) at 120 kV and virtual monoenergetic images (MEIs) and AMEIs at six different kiloelectron volt (keV) levels (from 40 to 90 keV) were evaluated from the 100 and Sn 140 kV dual energy image data, respectively. The visibility and stage migration of EGC for all three image data sets were evaluated and statistically analyzed. The objective and subjective image qualities were also evaluated. RESULTS: AMEIs at 40 keV showed the best visibility (80.7 %) and the lowest stage migration (35.5 %) for EGC. The stage migration for AMEIs at 40 keV was significantly lower than that for PEIs (p = 0.026). AMEIs at 40 keV had statistically higher CNR in the arterial and portal phases, gastric-specific diagnostic performance and visual sharpness compared with other AMEIs, MEIs and PEIs (all p < 0.05). CONCLUSIONS: AMEIs at 40 keV with MPR increase the CNR of EGC and thus potentially lower the stage migration of EGC. KEY POINTS: • AMEIs benefits from the recombination of low-keV images and medium energies. • AMEIs could receive better CNR results than MEIs. • AMEIs at 40 keV potentially lower the stage migration of EGC. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (doi:10.1007/s00330-016-4442-z) contains supplementary material, which is available to authorized users. Springer Berlin Heidelberg 2016-06-08 2017 /pmc/articles/PMC5209438/ /pubmed/27271924 http://dx.doi.org/10.1007/s00330-016-4442-z Text en © The Author(s) 2016 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Computed Tomography
Shi, Cen
Zhang, Huan
Yan, Jing
Wang, Baisong
Du, Lianjun
Pan, Zilai
Yan, Fuhua
Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study
title Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study
title_full Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study
title_fullStr Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study
title_full_unstemmed Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study
title_short Decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy CT images: a preliminary study
title_sort decreased stage migration rate of early gastric cancer with a new reconstruction algorithm using dual-energy ct images: a preliminary study
topic Computed Tomography
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5209438/
https://www.ncbi.nlm.nih.gov/pubmed/27271924
http://dx.doi.org/10.1007/s00330-016-4442-z
work_keys_str_mv AT shicen decreasedstagemigrationrateofearlygastriccancerwithanewreconstructionalgorithmusingdualenergyctimagesapreliminarystudy
AT zhanghuan decreasedstagemigrationrateofearlygastriccancerwithanewreconstructionalgorithmusingdualenergyctimagesapreliminarystudy
AT yanjing decreasedstagemigrationrateofearlygastriccancerwithanewreconstructionalgorithmusingdualenergyctimagesapreliminarystudy
AT wangbaisong decreasedstagemigrationrateofearlygastriccancerwithanewreconstructionalgorithmusingdualenergyctimagesapreliminarystudy
AT dulianjun decreasedstagemigrationrateofearlygastriccancerwithanewreconstructionalgorithmusingdualenergyctimagesapreliminarystudy
AT panzilai decreasedstagemigrationrateofearlygastriccancerwithanewreconstructionalgorithmusingdualenergyctimagesapreliminarystudy
AT yanfuhua decreasedstagemigrationrateofearlygastriccancerwithanewreconstructionalgorithmusingdualenergyctimagesapreliminarystudy