Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model

Stent struts protruding into ostial side branch called “jailed strut” at bifurcation lesions is a likely cause of thrombus formation. We aimed to investigate the influences of multiple kissing balloon inflation (KBI) for stent expansion, and stent platform design, respectively, on the reduction of i...

Descripción completa

Detalles Bibliográficos
Autores principales: Hikichi, Yutaka, Umezu, Mitsuo, Node, Koichi, Iwasaki, Kiyotaka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Japan 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5214711/
https://www.ncbi.nlm.nih.gov/pubmed/26968169
http://dx.doi.org/10.1007/s12928-016-0380-6
_version_ 1782491653947260928
author Hikichi, Yutaka
Umezu, Mitsuo
Node, Koichi
Iwasaki, Kiyotaka
author_facet Hikichi, Yutaka
Umezu, Mitsuo
Node, Koichi
Iwasaki, Kiyotaka
author_sort Hikichi, Yutaka
collection PubMed
description Stent struts protruding into ostial side branch called “jailed strut” at bifurcation lesions is a likely cause of thrombus formation. We aimed to investigate the influences of multiple kissing balloon inflation (KBI) for stent expansion, and stent platform design, respectively, on the reduction of incomplete stent apposition area (ISA area) caused by jailed struts at a side-branch ostium, using a three-dimensional elastic left main (LM) bifurcated coronary artery model. The referenced LM bifurcation angle data of 209 patients were stratified by tertiles focusing on the angle between the LM trunk (LMT) and left anterior descending artery (LAD). A bifurcation model was fabricated with angles of 129°, 122.2°, and 76.4° for LMT–LAD, LMT–left circumflex (LCx), and LAD–LCx, respectively, and with diameters of 5, 3.75, and 3.5 mm for LMT, LAD, and LCx, respectively; these diameters fulfill Murray’s law. A 75 % stenosis was included along the LMT. One-time and three-time KBIs were conducted using two-link Nobori and three-link Xience Xpedition (n = 6 each). The ISA area was quantified using micro-CT. Three-time KBI was effective in reducing the ISA area compared with one-time KBI for both the Nobori (p = 0.05) and Xience Xpedition (p = 0.07). The ISA area was smaller in the Nobori than in the Xience Xpedition, both in one-time and three-time KBI (one-time KBI: p = 0.003; three-time KBI: p = 0.001). Our findings of this study on reducing the ISA area by focusing on an interventional technique and stent design may help to improve coronary bifurcation intervention for a possibly better long-term clinical outcome.
format Online
Article
Text
id pubmed-5214711
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Springer Japan
record_format MEDLINE/PubMed
spelling pubmed-52147112017-01-24 Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model Hikichi, Yutaka Umezu, Mitsuo Node, Koichi Iwasaki, Kiyotaka Cardiovasc Interv Ther Original Article Stent struts protruding into ostial side branch called “jailed strut” at bifurcation lesions is a likely cause of thrombus formation. We aimed to investigate the influences of multiple kissing balloon inflation (KBI) for stent expansion, and stent platform design, respectively, on the reduction of incomplete stent apposition area (ISA area) caused by jailed struts at a side-branch ostium, using a three-dimensional elastic left main (LM) bifurcated coronary artery model. The referenced LM bifurcation angle data of 209 patients were stratified by tertiles focusing on the angle between the LM trunk (LMT) and left anterior descending artery (LAD). A bifurcation model was fabricated with angles of 129°, 122.2°, and 76.4° for LMT–LAD, LMT–left circumflex (LCx), and LAD–LCx, respectively, and with diameters of 5, 3.75, and 3.5 mm for LMT, LAD, and LCx, respectively; these diameters fulfill Murray’s law. A 75 % stenosis was included along the LMT. One-time and three-time KBIs were conducted using two-link Nobori and three-link Xience Xpedition (n = 6 each). The ISA area was quantified using micro-CT. Three-time KBI was effective in reducing the ISA area compared with one-time KBI for both the Nobori (p = 0.05) and Xience Xpedition (p = 0.07). The ISA area was smaller in the Nobori than in the Xience Xpedition, both in one-time and three-time KBI (one-time KBI: p = 0.003; three-time KBI: p = 0.001). Our findings of this study on reducing the ISA area by focusing on an interventional technique and stent design may help to improve coronary bifurcation intervention for a possibly better long-term clinical outcome. Springer Japan 2016-03-11 2017 /pmc/articles/PMC5214711/ /pubmed/26968169 http://dx.doi.org/10.1007/s12928-016-0380-6 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Hikichi, Yutaka
Umezu, Mitsuo
Node, Koichi
Iwasaki, Kiyotaka
Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model
title Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model
title_full Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model
title_fullStr Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model
title_full_unstemmed Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model
title_short Reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-CT analysis using a three-dimensional elastic bifurcated coronary artery model
title_sort reduction in incomplete stent apposition area caused by jailed struts after single stenting at left main bifurcation lesions: micro-ct analysis using a three-dimensional elastic bifurcated coronary artery model
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5214711/
https://www.ncbi.nlm.nih.gov/pubmed/26968169
http://dx.doi.org/10.1007/s12928-016-0380-6
work_keys_str_mv AT hikichiyutaka reductioninincompletestentappositionareacausedbyjailedstrutsaftersinglestentingatleftmainbifurcationlesionsmicroctanalysisusingathreedimensionalelasticbifurcatedcoronaryarterymodel
AT umezumitsuo reductioninincompletestentappositionareacausedbyjailedstrutsaftersinglestentingatleftmainbifurcationlesionsmicroctanalysisusingathreedimensionalelasticbifurcatedcoronaryarterymodel
AT nodekoichi reductioninincompletestentappositionareacausedbyjailedstrutsaftersinglestentingatleftmainbifurcationlesionsmicroctanalysisusingathreedimensionalelasticbifurcatedcoronaryarterymodel
AT iwasakikiyotaka reductioninincompletestentappositionareacausedbyjailedstrutsaftersinglestentingatleftmainbifurcationlesionsmicroctanalysisusingathreedimensionalelasticbifurcatedcoronaryarterymodel