Evaluation of Radiation Dose Received by Premature Neonates Admitted to Neonatal Intensive Care Unit
BACKGROUND: This study aimed to evaluate the radiation dose received by premature neonates using diagnostic radiographies. METHODS: This cross-sectional study was conducted on 116 premature neonates with gestational age from 25 to 37 weeks; with the diagnosis of neonatal respiratory distress syndrom...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elmer Press
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5215016/ https://www.ncbi.nlm.nih.gov/pubmed/28090228 http://dx.doi.org/10.14740/jocmr2796w |
_version_ | 1782491709861527552 |
---|---|
author | Aramesh, Mohmmadreza Zanganeh, Kobra Aria Dehdashtian, Masoud Malekian, Arash Fatahiasl, Jafar |
author_facet | Aramesh, Mohmmadreza Zanganeh, Kobra Aria Dehdashtian, Masoud Malekian, Arash Fatahiasl, Jafar |
author_sort | Aramesh, Mohmmadreza |
collection | PubMed |
description | BACKGROUND: This study aimed to evaluate the radiation dose received by premature neonates using diagnostic radiographies. METHODS: This cross-sectional study was conducted on 116 premature neonates with gestational age from 25 to 37 weeks; with the diagnosis of neonatal respiratory distress syndrome (NRDS) and tachypnea, they were admitted to a neonatal intensive care unit (NICU) at Ahvaz Imam Khomeini Hospital in 2015. For assessing the dose received, the model GR-200 thermoluminescent dosimeter (TLD) was used. For each premature neonate under radiation, three TLDs separately (one for each) were placed on surfaces of Ch1, T1, and G1 (chest, thyroid, and gonad of first newborn, respectively). Moreover, for the adjacent neonate at a distance of 60 - 100 cm, two TLDs were laid in the surfaces of T2 and G2 (thyroid and gonad of second newborn, respectively). The dose received by TLDs for any baby and the adjacent neonate under the entrance surface dose (ESD) was estimated. RESULTS: The mean of neonates’ weight under study was 1,950.78 ± 484.9 g. During the hospitalization period, minimum one and maximum three radiographies were done for any premature neonate. The doses received in the premature neonates to Ch1, T1 and G1 were 0.08 ± 0.01, 0.06 ± 0.01, and 0.05 ± 0.01 mSv, respectively and for adjacent infants for T2 and G2 were 0.003 ± 0.001 and 0.002 ± 0.0009 mSv, respectively. CONCLUSIONS: In the study, radiation dose received by organs at risk of premature neonates was lower than the international criteria and standards, therefore, also due to the lack of radiation damage threshold, to limit collimator, and the use of the proper filtration, kilovoltage and time during radiography of premature neonates are recommended. |
format | Online Article Text |
id | pubmed-5215016 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Elmer Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-52150162017-01-13 Evaluation of Radiation Dose Received by Premature Neonates Admitted to Neonatal Intensive Care Unit Aramesh, Mohmmadreza Zanganeh, Kobra Aria Dehdashtian, Masoud Malekian, Arash Fatahiasl, Jafar J Clin Med Res Original Article BACKGROUND: This study aimed to evaluate the radiation dose received by premature neonates using diagnostic radiographies. METHODS: This cross-sectional study was conducted on 116 premature neonates with gestational age from 25 to 37 weeks; with the diagnosis of neonatal respiratory distress syndrome (NRDS) and tachypnea, they were admitted to a neonatal intensive care unit (NICU) at Ahvaz Imam Khomeini Hospital in 2015. For assessing the dose received, the model GR-200 thermoluminescent dosimeter (TLD) was used. For each premature neonate under radiation, three TLDs separately (one for each) were placed on surfaces of Ch1, T1, and G1 (chest, thyroid, and gonad of first newborn, respectively). Moreover, for the adjacent neonate at a distance of 60 - 100 cm, two TLDs were laid in the surfaces of T2 and G2 (thyroid and gonad of second newborn, respectively). The dose received by TLDs for any baby and the adjacent neonate under the entrance surface dose (ESD) was estimated. RESULTS: The mean of neonates’ weight under study was 1,950.78 ± 484.9 g. During the hospitalization period, minimum one and maximum three radiographies were done for any premature neonate. The doses received in the premature neonates to Ch1, T1 and G1 were 0.08 ± 0.01, 0.06 ± 0.01, and 0.05 ± 0.01 mSv, respectively and for adjacent infants for T2 and G2 were 0.003 ± 0.001 and 0.002 ± 0.0009 mSv, respectively. CONCLUSIONS: In the study, radiation dose received by organs at risk of premature neonates was lower than the international criteria and standards, therefore, also due to the lack of radiation damage threshold, to limit collimator, and the use of the proper filtration, kilovoltage and time during radiography of premature neonates are recommended. Elmer Press 2017-02 2016-12-31 /pmc/articles/PMC5215016/ /pubmed/28090228 http://dx.doi.org/10.14740/jocmr2796w Text en Copyright 2017, Aramesh et al. http://creativecommons.org/licenses/by-nc/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Original Article Aramesh, Mohmmadreza Zanganeh, Kobra Aria Dehdashtian, Masoud Malekian, Arash Fatahiasl, Jafar Evaluation of Radiation Dose Received by Premature Neonates Admitted to Neonatal Intensive Care Unit |
title | Evaluation of Radiation Dose Received by Premature Neonates Admitted to Neonatal Intensive Care Unit |
title_full | Evaluation of Radiation Dose Received by Premature Neonates Admitted to Neonatal Intensive Care Unit |
title_fullStr | Evaluation of Radiation Dose Received by Premature Neonates Admitted to Neonatal Intensive Care Unit |
title_full_unstemmed | Evaluation of Radiation Dose Received by Premature Neonates Admitted to Neonatal Intensive Care Unit |
title_short | Evaluation of Radiation Dose Received by Premature Neonates Admitted to Neonatal Intensive Care Unit |
title_sort | evaluation of radiation dose received by premature neonates admitted to neonatal intensive care unit |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5215016/ https://www.ncbi.nlm.nih.gov/pubmed/28090228 http://dx.doi.org/10.14740/jocmr2796w |
work_keys_str_mv | AT arameshmohmmadreza evaluationofradiationdosereceivedbyprematureneonatesadmittedtoneonatalintensivecareunit AT zanganehkobraaria evaluationofradiationdosereceivedbyprematureneonatesadmittedtoneonatalintensivecareunit AT dehdashtianmasoud evaluationofradiationdosereceivedbyprematureneonatesadmittedtoneonatalintensivecareunit AT malekianarash evaluationofradiationdosereceivedbyprematureneonatesadmittedtoneonatalintensivecareunit AT fatahiasljafar evaluationofradiationdosereceivedbyprematureneonatesadmittedtoneonatalintensivecareunit |