Cargando…

A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection

Golgi protein 73 (GP73) is a novel and potential marker for diagnosing hepatocellular carcinoma (HCC) that has been found to be abnormally elevated in liver disease. A latex particle-enhanced turbidimetric immunoassay (LTIA) was recently introduced and licensed for application in a variety of automa...

Descripción completa

Detalles Bibliográficos
Autores principales: Xia, Yanyan, Shen, Han, Zhu, Yefei, Xu, Hongpan, Li, Zhiyang, Si, Jin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5215377/
https://www.ncbi.nlm.nih.gov/pubmed/28054632
http://dx.doi.org/10.1038/srep40090
_version_ 1782491749769281536
author Xia, Yanyan
Shen, Han
Zhu, Yefei
Xu, Hongpan
Li, Zhiyang
Si, Jin
author_facet Xia, Yanyan
Shen, Han
Zhu, Yefei
Xu, Hongpan
Li, Zhiyang
Si, Jin
author_sort Xia, Yanyan
collection PubMed
description Golgi protein 73 (GP73) is a novel and potential marker for diagnosing hepatocellular carcinoma (HCC) that has been found to be abnormally elevated in liver disease. A latex particle-enhanced turbidimetric immunoassay (LTIA) was recently introduced and licensed for application in a variety of automated clinical chemistry analyzers. However, no studies have reported sufficient data on analytical performance of this method when using 3 monoclonal antibodies for GP73 measurement. The experimental conditions were firstly optimized and range of linearity, diagnostic potential, clinical relevance were compared with the LTIA based on polyclonal antibodies and ELISA. Dilution tests for the LTIA using 3 monoclonal antibodies produced a calibration curve from 10 to 350 ng/mL while the polyclonal antibodies produced the curve from 20 to 320 ng/mL. The detection limit was achieved at 1.82 ng/mL concentration. Within-run CV was obtained in the range of 1.5–2.9% and ROC curves indicated sensitivity and specificity of the LTIA based on 3 monoclonal antibodies were 96.7% and 93.3%, respectively, higher than for the polyclonal antibodies (94.6% and 72.4%) and ELISA (70.0% and 83.3%). Therefore, the LTIA assay based on 3 monoclonal antibodies is thus applicable in quantification of GP73 concentration in automated biochemistry analyzers.
format Online
Article
Text
id pubmed-5215377
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Nature Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-52153772017-01-09 A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection Xia, Yanyan Shen, Han Zhu, Yefei Xu, Hongpan Li, Zhiyang Si, Jin Sci Rep Article Golgi protein 73 (GP73) is a novel and potential marker for diagnosing hepatocellular carcinoma (HCC) that has been found to be abnormally elevated in liver disease. A latex particle-enhanced turbidimetric immunoassay (LTIA) was recently introduced and licensed for application in a variety of automated clinical chemistry analyzers. However, no studies have reported sufficient data on analytical performance of this method when using 3 monoclonal antibodies for GP73 measurement. The experimental conditions were firstly optimized and range of linearity, diagnostic potential, clinical relevance were compared with the LTIA based on polyclonal antibodies and ELISA. Dilution tests for the LTIA using 3 monoclonal antibodies produced a calibration curve from 10 to 350 ng/mL while the polyclonal antibodies produced the curve from 20 to 320 ng/mL. The detection limit was achieved at 1.82 ng/mL concentration. Within-run CV was obtained in the range of 1.5–2.9% and ROC curves indicated sensitivity and specificity of the LTIA based on 3 monoclonal antibodies were 96.7% and 93.3%, respectively, higher than for the polyclonal antibodies (94.6% and 72.4%) and ELISA (70.0% and 83.3%). Therefore, the LTIA assay based on 3 monoclonal antibodies is thus applicable in quantification of GP73 concentration in automated biochemistry analyzers. Nature Publishing Group 2017-01-05 /pmc/articles/PMC5215377/ /pubmed/28054632 http://dx.doi.org/10.1038/srep40090 Text en Copyright © 2017, The Author(s) http://creativecommons.org/licenses/by/4.0/ This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/
spellingShingle Article
Xia, Yanyan
Shen, Han
Zhu, Yefei
Xu, Hongpan
Li, Zhiyang
Si, Jin
A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection
title A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection
title_full A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection
title_fullStr A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection
title_full_unstemmed A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection
title_short A sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for Golgi protein 73 detection
title_sort sensitive three monoclonal antibodies based automatic latex particle-enhanced turbidimetric immunoassay for golgi protein 73 detection
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5215377/
https://www.ncbi.nlm.nih.gov/pubmed/28054632
http://dx.doi.org/10.1038/srep40090
work_keys_str_mv AT xiayanyan asensitivethreemonoclonalantibodiesbasedautomaticlatexparticleenhancedturbidimetricimmunoassayforgolgiprotein73detection
AT shenhan asensitivethreemonoclonalantibodiesbasedautomaticlatexparticleenhancedturbidimetricimmunoassayforgolgiprotein73detection
AT zhuyefei asensitivethreemonoclonalantibodiesbasedautomaticlatexparticleenhancedturbidimetricimmunoassayforgolgiprotein73detection
AT xuhongpan asensitivethreemonoclonalantibodiesbasedautomaticlatexparticleenhancedturbidimetricimmunoassayforgolgiprotein73detection
AT lizhiyang asensitivethreemonoclonalantibodiesbasedautomaticlatexparticleenhancedturbidimetricimmunoassayforgolgiprotein73detection
AT sijin asensitivethreemonoclonalantibodiesbasedautomaticlatexparticleenhancedturbidimetricimmunoassayforgolgiprotein73detection
AT xiayanyan sensitivethreemonoclonalantibodiesbasedautomaticlatexparticleenhancedturbidimetricimmunoassayforgolgiprotein73detection
AT shenhan sensitivethreemonoclonalantibodiesbasedautomaticlatexparticleenhancedturbidimetricimmunoassayforgolgiprotein73detection
AT zhuyefei sensitivethreemonoclonalantibodiesbasedautomaticlatexparticleenhancedturbidimetricimmunoassayforgolgiprotein73detection
AT xuhongpan sensitivethreemonoclonalantibodiesbasedautomaticlatexparticleenhancedturbidimetricimmunoassayforgolgiprotein73detection
AT lizhiyang sensitivethreemonoclonalantibodiesbasedautomaticlatexparticleenhancedturbidimetricimmunoassayforgolgiprotein73detection
AT sijin sensitivethreemonoclonalantibodiesbasedautomaticlatexparticleenhancedturbidimetricimmunoassayforgolgiprotein73detection