Cargando…
Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants
AIM: This study assessed the feasibility and obtrusiveness of measuring salivary oxytocin in preterm infants receiving Kangaroo care, because this is a period of maximal bonding or co‐regulation. We also analysed possible influential determinants, including maternal oxytocin. METHODS: The saliva of...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5215538/ https://www.ncbi.nlm.nih.gov/pubmed/27666329 http://dx.doi.org/10.1111/apa.13606 |
_version_ | 1782491776877068288 |
---|---|
author | Kommers, DR Broeren, MAC Andriessen, P Oei, SG Feijs, L Bambang Oetomo, S |
author_facet | Kommers, DR Broeren, MAC Andriessen, P Oei, SG Feijs, L Bambang Oetomo, S |
author_sort | Kommers, DR |
collection | PubMed |
description | AIM: This study assessed the feasibility and obtrusiveness of measuring salivary oxytocin in preterm infants receiving Kangaroo care, because this is a period of maximal bonding or co‐regulation. We also analysed possible influential determinants, including maternal oxytocin. METHODS: The saliva of preterm infants and their mothers was collected prior to, and during, Kangaroo care using cotton swabs and pooled into vials until sufficient volumes were obtained to measure oxytocin levels using a radioimmunoassay. The obtrusiveness of the infants’ collections was measured with a Likert scale. RESULTS: Saliva was collected unobtrusively prior to, and during, 30 Kangaroo care sessions in 21 preterm infants. This resulted in three vials with sufficient volumes of before‐Kangaroo care saliva and three with during‐Kangaroo care saliva. Oxytocin was detectable in all six vials. The Kangaroo care duration and the intensity of the mother–infant interaction before and during Kangaroo care seemed to be the most important determinants, and these should preferably be standardised in any future trials. CONCLUSION: Oxytocin was measured unobtrusively in the pooled saliva of preterm infants both before and during Kangaroo care and could therefore be investigated as a biomarker in future studies. |
format | Online Article Text |
id | pubmed-5215538 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-52155382017-01-18 Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants Kommers, DR Broeren, MAC Andriessen, P Oei, SG Feijs, L Bambang Oetomo, S Acta Paediatr Regular Articles AIM: This study assessed the feasibility and obtrusiveness of measuring salivary oxytocin in preterm infants receiving Kangaroo care, because this is a period of maximal bonding or co‐regulation. We also analysed possible influential determinants, including maternal oxytocin. METHODS: The saliva of preterm infants and their mothers was collected prior to, and during, Kangaroo care using cotton swabs and pooled into vials until sufficient volumes were obtained to measure oxytocin levels using a radioimmunoassay. The obtrusiveness of the infants’ collections was measured with a Likert scale. RESULTS: Saliva was collected unobtrusively prior to, and during, 30 Kangaroo care sessions in 21 preterm infants. This resulted in three vials with sufficient volumes of before‐Kangaroo care saliva and three with during‐Kangaroo care saliva. Oxytocin was detectable in all six vials. The Kangaroo care duration and the intensity of the mother–infant interaction before and during Kangaroo care seemed to be the most important determinants, and these should preferably be standardised in any future trials. CONCLUSION: Oxytocin was measured unobtrusively in the pooled saliva of preterm infants both before and during Kangaroo care and could therefore be investigated as a biomarker in future studies. John Wiley and Sons Inc. 2016-10-17 2017-01 /pmc/articles/PMC5215538/ /pubmed/27666329 http://dx.doi.org/10.1111/apa.13606 Text en ©2016 The Authors. Acta Pædiatrica published by John Wiley & Sons Ltd on behalf of Foundation Acta Pædiatrica. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial (http://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. |
spellingShingle | Regular Articles Kommers, DR Broeren, MAC Andriessen, P Oei, SG Feijs, L Bambang Oetomo, S Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants |
title | Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants |
title_full | Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants |
title_fullStr | Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants |
title_full_unstemmed | Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants |
title_short | Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants |
title_sort | pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants |
topic | Regular Articles |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5215538/ https://www.ncbi.nlm.nih.gov/pubmed/27666329 http://dx.doi.org/10.1111/apa.13606 |
work_keys_str_mv | AT kommersdr pilotstudydemonstratesthatsalivaryoxytocincanbemeasuredunobtrusivelyinpreterminfants AT broerenmac pilotstudydemonstratesthatsalivaryoxytocincanbemeasuredunobtrusivelyinpreterminfants AT andriessenp pilotstudydemonstratesthatsalivaryoxytocincanbemeasuredunobtrusivelyinpreterminfants AT oeisg pilotstudydemonstratesthatsalivaryoxytocincanbemeasuredunobtrusivelyinpreterminfants AT feijsl pilotstudydemonstratesthatsalivaryoxytocincanbemeasuredunobtrusivelyinpreterminfants AT bambangoetomos pilotstudydemonstratesthatsalivaryoxytocincanbemeasuredunobtrusivelyinpreterminfants |