Cargando…

Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants

AIM: This study assessed the feasibility and obtrusiveness of measuring salivary oxytocin in preterm infants receiving Kangaroo care, because this is a period of maximal bonding or co‐regulation. We also analysed possible influential determinants, including maternal oxytocin. METHODS: The saliva of...

Descripción completa

Detalles Bibliográficos
Autores principales: Kommers, DR, Broeren, MAC, Andriessen, P, Oei, SG, Feijs, L, Bambang Oetomo, S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5215538/
https://www.ncbi.nlm.nih.gov/pubmed/27666329
http://dx.doi.org/10.1111/apa.13606
_version_ 1782491776877068288
author Kommers, DR
Broeren, MAC
Andriessen, P
Oei, SG
Feijs, L
Bambang Oetomo, S
author_facet Kommers, DR
Broeren, MAC
Andriessen, P
Oei, SG
Feijs, L
Bambang Oetomo, S
author_sort Kommers, DR
collection PubMed
description AIM: This study assessed the feasibility and obtrusiveness of measuring salivary oxytocin in preterm infants receiving Kangaroo care, because this is a period of maximal bonding or co‐regulation. We also analysed possible influential determinants, including maternal oxytocin. METHODS: The saliva of preterm infants and their mothers was collected prior to, and during, Kangaroo care using cotton swabs and pooled into vials until sufficient volumes were obtained to measure oxytocin levels using a radioimmunoassay. The obtrusiveness of the infants’ collections was measured with a Likert scale. RESULTS: Saliva was collected unobtrusively prior to, and during, 30 Kangaroo care sessions in 21 preterm infants. This resulted in three vials with sufficient volumes of before‐Kangaroo care saliva and three with during‐Kangaroo care saliva. Oxytocin was detectable in all six vials. The Kangaroo care duration and the intensity of the mother–infant interaction before and during Kangaroo care seemed to be the most important determinants, and these should preferably be standardised in any future trials. CONCLUSION: Oxytocin was measured unobtrusively in the pooled saliva of preterm infants both before and during Kangaroo care and could therefore be investigated as a biomarker in future studies.
format Online
Article
Text
id pubmed-5215538
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-52155382017-01-18 Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants Kommers, DR Broeren, MAC Andriessen, P Oei, SG Feijs, L Bambang Oetomo, S Acta Paediatr Regular Articles AIM: This study assessed the feasibility and obtrusiveness of measuring salivary oxytocin in preterm infants receiving Kangaroo care, because this is a period of maximal bonding or co‐regulation. We also analysed possible influential determinants, including maternal oxytocin. METHODS: The saliva of preterm infants and their mothers was collected prior to, and during, Kangaroo care using cotton swabs and pooled into vials until sufficient volumes were obtained to measure oxytocin levels using a radioimmunoassay. The obtrusiveness of the infants’ collections was measured with a Likert scale. RESULTS: Saliva was collected unobtrusively prior to, and during, 30 Kangaroo care sessions in 21 preterm infants. This resulted in three vials with sufficient volumes of before‐Kangaroo care saliva and three with during‐Kangaroo care saliva. Oxytocin was detectable in all six vials. The Kangaroo care duration and the intensity of the mother–infant interaction before and during Kangaroo care seemed to be the most important determinants, and these should preferably be standardised in any future trials. CONCLUSION: Oxytocin was measured unobtrusively in the pooled saliva of preterm infants both before and during Kangaroo care and could therefore be investigated as a biomarker in future studies. John Wiley and Sons Inc. 2016-10-17 2017-01 /pmc/articles/PMC5215538/ /pubmed/27666329 http://dx.doi.org/10.1111/apa.13606 Text en ©2016 The Authors. Acta Pædiatrica published by John Wiley & Sons Ltd on behalf of Foundation Acta Pædiatrica. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial (http://creativecommons.org/licenses/by-nc/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Regular Articles
Kommers, DR
Broeren, MAC
Andriessen, P
Oei, SG
Feijs, L
Bambang Oetomo, S
Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants
title Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants
title_full Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants
title_fullStr Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants
title_full_unstemmed Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants
title_short Pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants
title_sort pilot study demonstrates that salivary oxytocin can be measured unobtrusively in preterm infants
topic Regular Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5215538/
https://www.ncbi.nlm.nih.gov/pubmed/27666329
http://dx.doi.org/10.1111/apa.13606
work_keys_str_mv AT kommersdr pilotstudydemonstratesthatsalivaryoxytocincanbemeasuredunobtrusivelyinpreterminfants
AT broerenmac pilotstudydemonstratesthatsalivaryoxytocincanbemeasuredunobtrusivelyinpreterminfants
AT andriessenp pilotstudydemonstratesthatsalivaryoxytocincanbemeasuredunobtrusivelyinpreterminfants
AT oeisg pilotstudydemonstratesthatsalivaryoxytocincanbemeasuredunobtrusivelyinpreterminfants
AT feijsl pilotstudydemonstratesthatsalivaryoxytocincanbemeasuredunobtrusivelyinpreterminfants
AT bambangoetomos pilotstudydemonstratesthatsalivaryoxytocincanbemeasuredunobtrusivelyinpreterminfants