Cargando…

Extraction of Respiratory Signal Based on Image Clustering and Intensity Parameters at Radiotherapy with External Beam: A Comparative Study

BACKGROUND: Since tumors located in thorax region of body mainly move due to respiration, in the modern radiotherapy, there have been many attempts such as; external markers, strain gage and spirometer represent for monitoring patients’ breathing signal. With the advent of fluoroscopy technique, ind...

Descripción completa

Detalles Bibliográficos
Autores principales: Samadi Miandoab, P., Esmaili Torshabi, A., Nankali, S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Journal of Biomedical Physics and Engineering 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5219576/
https://www.ncbi.nlm.nih.gov/pubmed/28144595
_version_ 1782492478016847872
author Samadi Miandoab, P.
Esmaili Torshabi, A.
Nankali, S.
author_facet Samadi Miandoab, P.
Esmaili Torshabi, A.
Nankali, S.
author_sort Samadi Miandoab, P.
collection PubMed
description BACKGROUND: Since tumors located in thorax region of body mainly move due to respiration, in the modern radiotherapy, there have been many attempts such as; external markers, strain gage and spirometer represent for monitoring patients’ breathing signal. With the advent of fluoroscopy technique, indirect methods were proposed as an alternative approach to extract patients’ breathing signals. MATERIALS AND METHODS: The purpose of this study is to extract respiratory signals using two available methods based on clustering and intensity strategies on medical image dataset of XCAT phantom. RESULTS: For testing and evaluation methods, correlation coefficient, standard division, amplitude ratio and different phases are utilized. Phantom study showed excellent match between correlation coefficient, standard division, amplitude ratio and different phase. Both techniques segmenting medical images are robust due to their inherent mathematical properties. Using clustering strategy, lung region borders are remarkably extracted regarding intensity-based method. This may also affect the amount of amplitude signal. CONCLUSION: To evaluate the performance of these methods, results are compared with slice body volume (SBV) method. Moreover, all methods have shown the same correlation coefficient of 99%, but at different amplitude ratio and different phase. In SBV method, standard division and different phase are better than clustering and intensity methods with SDR=4.71 mm, and SDL=4.12 mm and average different phase 1.47 %, but amplitude ration of clustering method is significantly more remarkable than SBV and intensity methods.
format Online
Article
Text
id pubmed-5219576
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Journal of Biomedical Physics and Engineering
record_format MEDLINE/PubMed
spelling pubmed-52195762017-01-31 Extraction of Respiratory Signal Based on Image Clustering and Intensity Parameters at Radiotherapy with External Beam: A Comparative Study Samadi Miandoab, P. Esmaili Torshabi, A. Nankali, S. J Biomed Phys Eng Original Article BACKGROUND: Since tumors located in thorax region of body mainly move due to respiration, in the modern radiotherapy, there have been many attempts such as; external markers, strain gage and spirometer represent for monitoring patients’ breathing signal. With the advent of fluoroscopy technique, indirect methods were proposed as an alternative approach to extract patients’ breathing signals. MATERIALS AND METHODS: The purpose of this study is to extract respiratory signals using two available methods based on clustering and intensity strategies on medical image dataset of XCAT phantom. RESULTS: For testing and evaluation methods, correlation coefficient, standard division, amplitude ratio and different phases are utilized. Phantom study showed excellent match between correlation coefficient, standard division, amplitude ratio and different phase. Both techniques segmenting medical images are robust due to their inherent mathematical properties. Using clustering strategy, lung region borders are remarkably extracted regarding intensity-based method. This may also affect the amount of amplitude signal. CONCLUSION: To evaluate the performance of these methods, results are compared with slice body volume (SBV) method. Moreover, all methods have shown the same correlation coefficient of 99%, but at different amplitude ratio and different phase. In SBV method, standard division and different phase are better than clustering and intensity methods with SDR=4.71 mm, and SDL=4.12 mm and average different phase 1.47 %, but amplitude ration of clustering method is significantly more remarkable than SBV and intensity methods. Journal of Biomedical Physics and Engineering 2016-12-01 /pmc/articles/PMC5219576/ /pubmed/28144595 Text en Copyright: © Journal of Biomedical Physics and Engineering http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Article
Samadi Miandoab, P.
Esmaili Torshabi, A.
Nankali, S.
Extraction of Respiratory Signal Based on Image Clustering and Intensity Parameters at Radiotherapy with External Beam: A Comparative Study
title Extraction of Respiratory Signal Based on Image Clustering and Intensity Parameters at Radiotherapy with External Beam: A Comparative Study
title_full Extraction of Respiratory Signal Based on Image Clustering and Intensity Parameters at Radiotherapy with External Beam: A Comparative Study
title_fullStr Extraction of Respiratory Signal Based on Image Clustering and Intensity Parameters at Radiotherapy with External Beam: A Comparative Study
title_full_unstemmed Extraction of Respiratory Signal Based on Image Clustering and Intensity Parameters at Radiotherapy with External Beam: A Comparative Study
title_short Extraction of Respiratory Signal Based on Image Clustering and Intensity Parameters at Radiotherapy with External Beam: A Comparative Study
title_sort extraction of respiratory signal based on image clustering and intensity parameters at radiotherapy with external beam: a comparative study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5219576/
https://www.ncbi.nlm.nih.gov/pubmed/28144595
work_keys_str_mv AT samadimiandoabp extractionofrespiratorysignalbasedonimageclusteringandintensityparametersatradiotherapywithexternalbeamacomparativestudy
AT esmailitorshabia extractionofrespiratorysignalbasedonimageclusteringandintensityparametersatradiotherapywithexternalbeamacomparativestudy
AT nankalis extractionofrespiratorysignalbasedonimageclusteringandintensityparametersatradiotherapywithexternalbeamacomparativestudy