Cargando…

Evaluation of Pulmonary Nodules Using the Spyglass Direct Visualization System Combined With Radial Endobronchial Ultrasound: A Clinical Feasibility Study

BACKGROUND: Sampling of peripheral pulmonary nodules with radial endobronchial ultrasound (p-EBUS) increases diagnostic yield of bronchoscopy. However, diagnostic yield is influenced by numerous factors. OBJECTIVE: We evaluated the use of SpyGlass, a one millimeter diameter optic fiber, to obtain im...

Descripción completa

Detalles Bibliográficos
Autores principales: Godbout, Krystelle, Martel, Simon, Simon, Mathieu, Lampron, Noël, Delage, Antoine
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Bentham Open 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5220169/
https://www.ncbi.nlm.nih.gov/pubmed/28144366
http://dx.doi.org/10.2174/1874306401610010079
_version_ 1782492576905953280
author Godbout, Krystelle
Martel, Simon
Simon, Mathieu
Lampron, Noël
Delage, Antoine
author_facet Godbout, Krystelle
Martel, Simon
Simon, Mathieu
Lampron, Noël
Delage, Antoine
author_sort Godbout, Krystelle
collection PubMed
description BACKGROUND: Sampling of peripheral pulmonary nodules with radial endobronchial ultrasound (p-EBUS) increases diagnostic yield of bronchoscopy. However, diagnostic yield is influenced by numerous factors. OBJECTIVE: We evaluated the use of SpyGlass, a one millimeter diameter optic fiber, to obtain images of the distal mucosa and of pulmonary lesions detected with p-EBUS to determine if visual aspect of the distal mucosa was predictive of diagnosis. METHODS: We prospectively recruited subjects investigated for peripheral nodules. Bronchoscopy was performed and p-EBUS was used to locate the lesion through a guide sheath. The Spyglass fiber was introduced in the sheath to obtain images of the distal bronchial mucosa. Tissue sampling was subsequently done. RESULTS: Fifteen patients were enrolled in the study. A final diagnosis of malignancy was confirmed in 80%. All lesions could be located using p-EBUS (100%). Diagnostic sensitivity for p-EBUS was 58.3%. Distal mucosa could be imaged with SpyGlass in 14/15 patients (93.3%). Mucosal appearance was described as abnormal in 7 out of the 15 subjects. Mean SpyGlass procedure time was 6.5 minutes. No direct complication was reported. CONCLUSION: Spyglass can be used in combination with p-EBUS to obtain images of the distal bronchial mucosa and peripheral pulmonary nodules. More patients will be needed to confirm whether mucosal appearance can be predictive of malignancy.
format Online
Article
Text
id pubmed-5220169
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Bentham Open
record_format MEDLINE/PubMed
spelling pubmed-52201692017-01-31 Evaluation of Pulmonary Nodules Using the Spyglass Direct Visualization System Combined With Radial Endobronchial Ultrasound: A Clinical Feasibility Study Godbout, Krystelle Martel, Simon Simon, Mathieu Lampron, Noël Delage, Antoine Open Respir Med J Article BACKGROUND: Sampling of peripheral pulmonary nodules with radial endobronchial ultrasound (p-EBUS) increases diagnostic yield of bronchoscopy. However, diagnostic yield is influenced by numerous factors. OBJECTIVE: We evaluated the use of SpyGlass, a one millimeter diameter optic fiber, to obtain images of the distal mucosa and of pulmonary lesions detected with p-EBUS to determine if visual aspect of the distal mucosa was predictive of diagnosis. METHODS: We prospectively recruited subjects investigated for peripheral nodules. Bronchoscopy was performed and p-EBUS was used to locate the lesion through a guide sheath. The Spyglass fiber was introduced in the sheath to obtain images of the distal bronchial mucosa. Tissue sampling was subsequently done. RESULTS: Fifteen patients were enrolled in the study. A final diagnosis of malignancy was confirmed in 80%. All lesions could be located using p-EBUS (100%). Diagnostic sensitivity for p-EBUS was 58.3%. Distal mucosa could be imaged with SpyGlass in 14/15 patients (93.3%). Mucosal appearance was described as abnormal in 7 out of the 15 subjects. Mean SpyGlass procedure time was 6.5 minutes. No direct complication was reported. CONCLUSION: Spyglass can be used in combination with p-EBUS to obtain images of the distal bronchial mucosa and peripheral pulmonary nodules. More patients will be needed to confirm whether mucosal appearance can be predictive of malignancy. Bentham Open 2016-11-30 /pmc/articles/PMC5220169/ /pubmed/28144366 http://dx.doi.org/10.2174/1874306401610010079 Text en © Godbout et al.; Licensee Bentham Open https://creativecommons.org/licenses/by/4.0/legalcode This is an open access article licensed under the terms of the Creative Commons Attribution-Non-Commercial 4.0 International Public License (CC BY-NC 4.0) (https://creativecommons.org/licenses/by-nc/4.0/legalcode), which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the work is properly cited.
spellingShingle Article
Godbout, Krystelle
Martel, Simon
Simon, Mathieu
Lampron, Noël
Delage, Antoine
Evaluation of Pulmonary Nodules Using the Spyglass Direct Visualization System Combined With Radial Endobronchial Ultrasound: A Clinical Feasibility Study
title Evaluation of Pulmonary Nodules Using the Spyglass Direct Visualization System Combined With Radial Endobronchial Ultrasound: A Clinical Feasibility Study
title_full Evaluation of Pulmonary Nodules Using the Spyglass Direct Visualization System Combined With Radial Endobronchial Ultrasound: A Clinical Feasibility Study
title_fullStr Evaluation of Pulmonary Nodules Using the Spyglass Direct Visualization System Combined With Radial Endobronchial Ultrasound: A Clinical Feasibility Study
title_full_unstemmed Evaluation of Pulmonary Nodules Using the Spyglass Direct Visualization System Combined With Radial Endobronchial Ultrasound: A Clinical Feasibility Study
title_short Evaluation of Pulmonary Nodules Using the Spyglass Direct Visualization System Combined With Radial Endobronchial Ultrasound: A Clinical Feasibility Study
title_sort evaluation of pulmonary nodules using the spyglass direct visualization system combined with radial endobronchial ultrasound: a clinical feasibility study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5220169/
https://www.ncbi.nlm.nih.gov/pubmed/28144366
http://dx.doi.org/10.2174/1874306401610010079
work_keys_str_mv AT godboutkrystelle evaluationofpulmonarynodulesusingthespyglassdirectvisualizationsystemcombinedwithradialendobronchialultrasoundaclinicalfeasibilitystudy
AT martelsimon evaluationofpulmonarynodulesusingthespyglassdirectvisualizationsystemcombinedwithradialendobronchialultrasoundaclinicalfeasibilitystudy
AT simonmathieu evaluationofpulmonarynodulesusingthespyglassdirectvisualizationsystemcombinedwithradialendobronchialultrasoundaclinicalfeasibilitystudy
AT lampronnoel evaluationofpulmonarynodulesusingthespyglassdirectvisualizationsystemcombinedwithradialendobronchialultrasoundaclinicalfeasibilitystudy
AT delageantoine evaluationofpulmonarynodulesusingthespyglassdirectvisualizationsystemcombinedwithradialendobronchialultrasoundaclinicalfeasibilitystudy