Cargando…

Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model

BACKGROUND: Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis. Based on a patient-specific CFD model, the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its a...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Hong-Yang, Liu, Long-Shan, Cao, Hai-Ming, Li, Jun, Deng, Rong-Hai, Fu, Qian, Zhang, Huan-Xi, Fei, Ji-Guang, Wang, Chang-Xi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5221107/
https://www.ncbi.nlm.nih.gov/pubmed/28051019
http://dx.doi.org/10.4103/0366-6999.196569
_version_ 1782492746657824768
author Wang, Hong-Yang
Liu, Long-Shan
Cao, Hai-Ming
Li, Jun
Deng, Rong-Hai
Fu, Qian
Zhang, Huan-Xi
Fei, Ji-Guang
Wang, Chang-Xi
author_facet Wang, Hong-Yang
Liu, Long-Shan
Cao, Hai-Ming
Li, Jun
Deng, Rong-Hai
Fu, Qian
Zhang, Huan-Xi
Fei, Ji-Guang
Wang, Chang-Xi
author_sort Wang, Hong-Yang
collection PubMed
description BACKGROUND: Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis. Based on a patient-specific CFD model, the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its alteration after stent treatment. METHODS: Computed tomography angiography (CTA) data of kidney transplant recipients in a single transplant center from April 2013 to November 2014 were reviewed. The three-dimensional geometry of transplant renal artery (TRA) was reconstructed from the qualified CTA images and categorized into three groups: the normal, stenotic, and stented groups. Hemodynamic parameters including pressure distribution, velocity, wall shear stress (WSS), and mass flow rate (MFR) were extracted. The data of hemodynamic parameters were expressed as median (interquartile range), and Mann–Whitney U-test was used for analysis. RESULTS: Totally, 6 normal, 12 stenotic, and 6 stented TRAs were included in the analysis. TRAS presented nonuniform pressure distribution, adverse pressure gradient across stenosis throat, flow vortex, and a separation zone at downstream stenosis. Stenotic arteries had higher maximal velocity and maximal WSS (2.94 [2.14, 3.30] vs. 1.06 [0.89, 1.15] m/s, 256.5 [149.8, 349.4] vs. 41.7 [37.8, 45.3] Pa at end diastole, P = 0.001; 3.25 [2.67, 3.56] vs. 1.65 [1.18, 1.72] m/s, 281.3 [184.3, 364.7] vs. 65.8 [61.2, 71.9] Pa at peak systole, P = 0.001) and lower minimal WSS and MFRs (0.07 [0.03, 0.13] vs. 0.52 [0.45, 0.67] Pa, 1.5 [1.0, 3.0] vs. 11.0 [8.0, 11.3] g/s at end diastole, P = 0.001; 0.08 [0.03, 0.19] vs. 0.70 [0.60, 0.81] Pa, 2.0 [1.3, 3.3] vs. 16.5 [13.0, 20.3] g/s at peak systole, P = 0.001) as compared to normal arteries. Stent implantation ameliorated all the alterations of the above hemodynamic factors except low WSS. CONCLUSIONS: Hemodynamic factors were significantly changed in severe TRAS. Stent implantation can restore or ameliorate deleterious change of hemodynamic factors except low WSS at stent regions.
format Online
Article
Text
id pubmed-5221107
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-52211072017-02-17 Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model Wang, Hong-Yang Liu, Long-Shan Cao, Hai-Ming Li, Jun Deng, Rong-Hai Fu, Qian Zhang, Huan-Xi Fei, Ji-Guang Wang, Chang-Xi Chin Med J (Engl) Original Article BACKGROUND: Accumulating studies on computational fluid dynamics (CFD) support the involvement of hemodynamic factors in artery stenosis. Based on a patient-specific CFD model, the present study aimed to investigate the hemodynamic characteristics of transplant renal artery stenosis (TRAS) and its alteration after stent treatment. METHODS: Computed tomography angiography (CTA) data of kidney transplant recipients in a single transplant center from April 2013 to November 2014 were reviewed. The three-dimensional geometry of transplant renal artery (TRA) was reconstructed from the qualified CTA images and categorized into three groups: the normal, stenotic, and stented groups. Hemodynamic parameters including pressure distribution, velocity, wall shear stress (WSS), and mass flow rate (MFR) were extracted. The data of hemodynamic parameters were expressed as median (interquartile range), and Mann–Whitney U-test was used for analysis. RESULTS: Totally, 6 normal, 12 stenotic, and 6 stented TRAs were included in the analysis. TRAS presented nonuniform pressure distribution, adverse pressure gradient across stenosis throat, flow vortex, and a separation zone at downstream stenosis. Stenotic arteries had higher maximal velocity and maximal WSS (2.94 [2.14, 3.30] vs. 1.06 [0.89, 1.15] m/s, 256.5 [149.8, 349.4] vs. 41.7 [37.8, 45.3] Pa at end diastole, P = 0.001; 3.25 [2.67, 3.56] vs. 1.65 [1.18, 1.72] m/s, 281.3 [184.3, 364.7] vs. 65.8 [61.2, 71.9] Pa at peak systole, P = 0.001) and lower minimal WSS and MFRs (0.07 [0.03, 0.13] vs. 0.52 [0.45, 0.67] Pa, 1.5 [1.0, 3.0] vs. 11.0 [8.0, 11.3] g/s at end diastole, P = 0.001; 0.08 [0.03, 0.19] vs. 0.70 [0.60, 0.81] Pa, 2.0 [1.3, 3.3] vs. 16.5 [13.0, 20.3] g/s at peak systole, P = 0.001) as compared to normal arteries. Stent implantation ameliorated all the alterations of the above hemodynamic factors except low WSS. CONCLUSIONS: Hemodynamic factors were significantly changed in severe TRAS. Stent implantation can restore or ameliorate deleterious change of hemodynamic factors except low WSS at stent regions. Medknow Publications & Media Pvt Ltd 2017-01-05 /pmc/articles/PMC5221107/ /pubmed/28051019 http://dx.doi.org/10.4103/0366-6999.196569 Text en Copyright: © 2017 Chinese Medical Journal http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Wang, Hong-Yang
Liu, Long-Shan
Cao, Hai-Ming
Li, Jun
Deng, Rong-Hai
Fu, Qian
Zhang, Huan-Xi
Fei, Ji-Guang
Wang, Chang-Xi
Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model
title Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model
title_full Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model
title_fullStr Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model
title_full_unstemmed Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model
title_short Hemodynamics in Transplant Renal Artery Stenosis and its Alteration after Stent Implantation Based on a Patient-specific Computational Fluid Dynamics Model
title_sort hemodynamics in transplant renal artery stenosis and its alteration after stent implantation based on a patient-specific computational fluid dynamics model
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5221107/
https://www.ncbi.nlm.nih.gov/pubmed/28051019
http://dx.doi.org/10.4103/0366-6999.196569
work_keys_str_mv AT wanghongyang hemodynamicsintransplantrenalarterystenosisanditsalterationafterstentimplantationbasedonapatientspecificcomputationalfluiddynamicsmodel
AT liulongshan hemodynamicsintransplantrenalarterystenosisanditsalterationafterstentimplantationbasedonapatientspecificcomputationalfluiddynamicsmodel
AT caohaiming hemodynamicsintransplantrenalarterystenosisanditsalterationafterstentimplantationbasedonapatientspecificcomputationalfluiddynamicsmodel
AT lijun hemodynamicsintransplantrenalarterystenosisanditsalterationafterstentimplantationbasedonapatientspecificcomputationalfluiddynamicsmodel
AT dengronghai hemodynamicsintransplantrenalarterystenosisanditsalterationafterstentimplantationbasedonapatientspecificcomputationalfluiddynamicsmodel
AT fuqian hemodynamicsintransplantrenalarterystenosisanditsalterationafterstentimplantationbasedonapatientspecificcomputationalfluiddynamicsmodel
AT zhanghuanxi hemodynamicsintransplantrenalarterystenosisanditsalterationafterstentimplantationbasedonapatientspecificcomputationalfluiddynamicsmodel
AT feijiguang hemodynamicsintransplantrenalarterystenosisanditsalterationafterstentimplantationbasedonapatientspecificcomputationalfluiddynamicsmodel
AT wangchangxi hemodynamicsintransplantrenalarterystenosisanditsalterationafterstentimplantationbasedonapatientspecificcomputationalfluiddynamicsmodel