Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs

BACKGROUND: We evaluated echocardiographic area-length methods to measure left ventricle (LV) volumes and ejection fraction (EF) in parasternal short axis views in comparison with cardiac computed tomography (CT) in pigs with chronic myocardial infarction (MI). METHODS: Male farm pigs with surgical...

Descripción completa

Detalles Bibliográficos
Autores principales: Ballo, Haitham, Tarkia, Miikka, Haavisto, Matti, Stark, Christoffer, Strandberg, Marjatta, Vähäsilta, Tommi, Saunavaara, Virva, Tolvanen, Tuula, Teräs, Mika, Hynninen, Ville-Veikko, Savunen, Timo, Roivainen, Anne, Knuuti, Juhani, Saraste, Antti
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5223339/
https://www.ncbi.nlm.nih.gov/pubmed/28069008
http://dx.doi.org/10.1186/s12947-016-0093-0
_version_ 1782493150075420672
author Ballo, Haitham
Tarkia, Miikka
Haavisto, Matti
Stark, Christoffer
Strandberg, Marjatta
Vähäsilta, Tommi
Saunavaara, Virva
Tolvanen, Tuula
Teräs, Mika
Hynninen, Ville-Veikko
Savunen, Timo
Roivainen, Anne
Knuuti, Juhani
Saraste, Antti
author_facet Ballo, Haitham
Tarkia, Miikka
Haavisto, Matti
Stark, Christoffer
Strandberg, Marjatta
Vähäsilta, Tommi
Saunavaara, Virva
Tolvanen, Tuula
Teräs, Mika
Hynninen, Ville-Veikko
Savunen, Timo
Roivainen, Anne
Knuuti, Juhani
Saraste, Antti
author_sort Ballo, Haitham
collection PubMed
description BACKGROUND: We evaluated echocardiographic area-length methods to measure left ventricle (LV) volumes and ejection fraction (EF) in parasternal short axis views in comparison with cardiac computed tomography (CT) in pigs with chronic myocardial infarction (MI). METHODS: Male farm pigs with surgical occlusion of the left anterior descending coronary artery (n = 9) or sham operation (n = 5) had transthoracic echocardiography and cardiac-CT 3 months after surgery. We measured length of the LV in parasternal long axis view, and both systolic and diastolic LV areas in parasternal short axis views at the level of mitral valve, papillary muscles and apex. Volumes and EF of the LV were calculated using Simpson’s method of discs (tri-plane area) or Cylinder-hemiellipsoid method (single plane area). RESULTS: The pigs with coronary occlusion had anterior MI scars and reduced EF (average EF 42 ± 10%) by CT. Measurements of LV volumes and EF were reproducible by echocardiography. Compared with CT, end-diastolic volume (EDV) measured by echocardiography showed good correlation and agreement using either Simpson’s method (r = 0.90; mean difference −2, 95% CI −47 to 43 mL) or Cylinder-hemiellipsoid method (r = 0.94; mean difference 3, 95% CI −44 to 49 mL). Furthermore, End-systolic volume (ESV) measured by echocardiography showed also good correlation and agreement using either Simpson’s method (r = 0.94; mean difference 12 ml, 95% CI: −16 to 40) or Cylinder-hemiellipsoid method (r = 0.97; mean difference:13 ml, 95% CI: −8 to 33). EF was underestimated using either Simpson’s method (r = 0.78; mean difference −6, 95% CI −11 to 1%) or Cylinder-hemiellipsoid method (r = 0.74; mean difference −4, 95% CI–10 to 2%). CONCLUSION: Our results indicate that measurement of LV volumes may be accurate, but EF is underestimated using either three or single parasternal short axis planes by echocardiography in a large animal model of chronic MI.
format Online
Article
Text
id pubmed-5223339
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-52233392017-01-11 Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs Ballo, Haitham Tarkia, Miikka Haavisto, Matti Stark, Christoffer Strandberg, Marjatta Vähäsilta, Tommi Saunavaara, Virva Tolvanen, Tuula Teräs, Mika Hynninen, Ville-Veikko Savunen, Timo Roivainen, Anne Knuuti, Juhani Saraste, Antti Cardiovasc Ultrasound Research BACKGROUND: We evaluated echocardiographic area-length methods to measure left ventricle (LV) volumes and ejection fraction (EF) in parasternal short axis views in comparison with cardiac computed tomography (CT) in pigs with chronic myocardial infarction (MI). METHODS: Male farm pigs with surgical occlusion of the left anterior descending coronary artery (n = 9) or sham operation (n = 5) had transthoracic echocardiography and cardiac-CT 3 months after surgery. We measured length of the LV in parasternal long axis view, and both systolic and diastolic LV areas in parasternal short axis views at the level of mitral valve, papillary muscles and apex. Volumes and EF of the LV were calculated using Simpson’s method of discs (tri-plane area) or Cylinder-hemiellipsoid method (single plane area). RESULTS: The pigs with coronary occlusion had anterior MI scars and reduced EF (average EF 42 ± 10%) by CT. Measurements of LV volumes and EF were reproducible by echocardiography. Compared with CT, end-diastolic volume (EDV) measured by echocardiography showed good correlation and agreement using either Simpson’s method (r = 0.90; mean difference −2, 95% CI −47 to 43 mL) or Cylinder-hemiellipsoid method (r = 0.94; mean difference 3, 95% CI −44 to 49 mL). Furthermore, End-systolic volume (ESV) measured by echocardiography showed also good correlation and agreement using either Simpson’s method (r = 0.94; mean difference 12 ml, 95% CI: −16 to 40) or Cylinder-hemiellipsoid method (r = 0.97; mean difference:13 ml, 95% CI: −8 to 33). EF was underestimated using either Simpson’s method (r = 0.78; mean difference −6, 95% CI −11 to 1%) or Cylinder-hemiellipsoid method (r = 0.74; mean difference −4, 95% CI–10 to 2%). CONCLUSION: Our results indicate that measurement of LV volumes may be accurate, but EF is underestimated using either three or single parasternal short axis planes by echocardiography in a large animal model of chronic MI. BioMed Central 2017-01-09 /pmc/articles/PMC5223339/ /pubmed/28069008 http://dx.doi.org/10.1186/s12947-016-0093-0 Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Ballo, Haitham
Tarkia, Miikka
Haavisto, Matti
Stark, Christoffer
Strandberg, Marjatta
Vähäsilta, Tommi
Saunavaara, Virva
Tolvanen, Tuula
Teräs, Mika
Hynninen, Ville-Veikko
Savunen, Timo
Roivainen, Anne
Knuuti, Juhani
Saraste, Antti
Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs
title Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs
title_full Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs
title_fullStr Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs
title_full_unstemmed Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs
title_short Accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac CT in pigs
title_sort accuracy of echocardiographic area-length method in chronic myocardial infarction: comparison with cardiac ct in pigs
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5223339/
https://www.ncbi.nlm.nih.gov/pubmed/28069008
http://dx.doi.org/10.1186/s12947-016-0093-0
work_keys_str_mv AT ballohaitham accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT tarkiamiikka accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT haavistomatti accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT starkchristoffer accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT strandbergmarjatta accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT vahasiltatommi accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT saunavaaravirva accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT tolvanentuula accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT terasmika accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT hynninenvilleveikko accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT savunentimo accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT roivainenanne accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT knuutijuhani accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs
AT sarasteantti accuracyofechocardiographicarealengthmethodinchronicmyocardialinfarctioncomparisonwithcardiacctinpigs