Cargando…

Perturbations of Circulating miRNAs in Irritable Bowel Syndrome Detected Using a Multiplexed High-throughput Gene Expression Platform

The gene expression platform assay allows for robust and highly reproducible quantification of the expression of up to 800 transcripts (mRNA or miRNAs) in a single reaction. The miRNA assay counts transcripts by directly imaging and digitally counting miRNA molecules that are labeled with color-code...

Descripción completa

Detalles Bibliográficos
Autores principales: Fourie, Nicolaas H., Peace, Ralph M., Abey, Sarah K., Sherwin, LeeAnne B., Wiley, John W., Henderson, Wendy A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MyJove Corporation 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5226328/
https://www.ncbi.nlm.nih.gov/pubmed/27929459
http://dx.doi.org/10.3791/54693
_version_ 1782493636562255872
author Fourie, Nicolaas H.
Peace, Ralph M.
Abey, Sarah K.
Sherwin, LeeAnne B.
Wiley, John W.
Henderson, Wendy A.
author_facet Fourie, Nicolaas H.
Peace, Ralph M.
Abey, Sarah K.
Sherwin, LeeAnne B.
Wiley, John W.
Henderson, Wendy A.
author_sort Fourie, Nicolaas H.
collection PubMed
description The gene expression platform assay allows for robust and highly reproducible quantification of the expression of up to 800 transcripts (mRNA or miRNAs) in a single reaction. The miRNA assay counts transcripts by directly imaging and digitally counting miRNA molecules that are labeled with color-coded fluorescent barcoded probe sets (a reporter probe and a capture probe). Barcodes are hybridized directly to mature miRNAs that have been elongated by ligating a unique oligonucleotide tag (miRtag) to the 3' end. Reverse transcription and amplification of the transcripts are not required. Reporter probes contain a sequence of six color positions populated using a combination of four fluorescent colors. The four colors over six positions are used to construct a gene-specific color barcode sequence. Post-hybridization processing is automated on a robotic prep station. After hybridization, the excess probes are washed away, and the tripartite structures (capture probe-miRNA-reporter probe) are fixed to a streptavidin-coated slide via the biotin-labeled capture probe. Imaging and barcode counting is done using a digital analyzer. The immobilized barcoded miRNAs are visualized and imaged using a microscope and camera, and the unique barcodes are decoded and counted. Data quality control (QC), normalization, and analysis are facilitated by a custom-designed data processing and analysis software that accompanies the assay software. The assay demonstrates high linearity over a broad range of expression, as well as high sensitivity. Sample and assay preparation does not involve enzymatic reactions, reverse transcription, or amplification; has few steps; and is largely automated, reducing investigator effects and resulting in high consistency and technical reproducibility. Here, we describe the application of this technology to identifying circulating miRNA perturbations in irritable bowel syndrome.
format Online
Article
Text
id pubmed-5226328
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher MyJove Corporation
record_format MEDLINE/PubMed
spelling pubmed-52263282017-01-26 Perturbations of Circulating miRNAs in Irritable Bowel Syndrome Detected Using a Multiplexed High-throughput Gene Expression Platform Fourie, Nicolaas H. Peace, Ralph M. Abey, Sarah K. Sherwin, LeeAnne B. Wiley, John W. Henderson, Wendy A. J Vis Exp Genetics The gene expression platform assay allows for robust and highly reproducible quantification of the expression of up to 800 transcripts (mRNA or miRNAs) in a single reaction. The miRNA assay counts transcripts by directly imaging and digitally counting miRNA molecules that are labeled with color-coded fluorescent barcoded probe sets (a reporter probe and a capture probe). Barcodes are hybridized directly to mature miRNAs that have been elongated by ligating a unique oligonucleotide tag (miRtag) to the 3' end. Reverse transcription and amplification of the transcripts are not required. Reporter probes contain a sequence of six color positions populated using a combination of four fluorescent colors. The four colors over six positions are used to construct a gene-specific color barcode sequence. Post-hybridization processing is automated on a robotic prep station. After hybridization, the excess probes are washed away, and the tripartite structures (capture probe-miRNA-reporter probe) are fixed to a streptavidin-coated slide via the biotin-labeled capture probe. Imaging and barcode counting is done using a digital analyzer. The immobilized barcoded miRNAs are visualized and imaged using a microscope and camera, and the unique barcodes are decoded and counted. Data quality control (QC), normalization, and analysis are facilitated by a custom-designed data processing and analysis software that accompanies the assay software. The assay demonstrates high linearity over a broad range of expression, as well as high sensitivity. Sample and assay preparation does not involve enzymatic reactions, reverse transcription, or amplification; has few steps; and is largely automated, reducing investigator effects and resulting in high consistency and technical reproducibility. Here, we describe the application of this technology to identifying circulating miRNA perturbations in irritable bowel syndrome. MyJove Corporation 2016-11-30 /pmc/articles/PMC5226328/ /pubmed/27929459 http://dx.doi.org/10.3791/54693 Text en Copyright © 2016, Journal of Visualized Experiments http://creativecommons.org/licenses/by-nc-nd/3.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visithttp://creativecommons.org/licenses/by-nc-nd/3.0/
spellingShingle Genetics
Fourie, Nicolaas H.
Peace, Ralph M.
Abey, Sarah K.
Sherwin, LeeAnne B.
Wiley, John W.
Henderson, Wendy A.
Perturbations of Circulating miRNAs in Irritable Bowel Syndrome Detected Using a Multiplexed High-throughput Gene Expression Platform
title Perturbations of Circulating miRNAs in Irritable Bowel Syndrome Detected Using a Multiplexed High-throughput Gene Expression Platform
title_full Perturbations of Circulating miRNAs in Irritable Bowel Syndrome Detected Using a Multiplexed High-throughput Gene Expression Platform
title_fullStr Perturbations of Circulating miRNAs in Irritable Bowel Syndrome Detected Using a Multiplexed High-throughput Gene Expression Platform
title_full_unstemmed Perturbations of Circulating miRNAs in Irritable Bowel Syndrome Detected Using a Multiplexed High-throughput Gene Expression Platform
title_short Perturbations of Circulating miRNAs in Irritable Bowel Syndrome Detected Using a Multiplexed High-throughput Gene Expression Platform
title_sort perturbations of circulating mirnas in irritable bowel syndrome detected using a multiplexed high-throughput gene expression platform
topic Genetics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5226328/
https://www.ncbi.nlm.nih.gov/pubmed/27929459
http://dx.doi.org/10.3791/54693
work_keys_str_mv AT fourienicolaash perturbationsofcirculatingmirnasinirritablebowelsyndromedetectedusingamultiplexedhighthroughputgeneexpressionplatform
AT peaceralphm perturbationsofcirculatingmirnasinirritablebowelsyndromedetectedusingamultiplexedhighthroughputgeneexpressionplatform
AT abeysarahk perturbationsofcirculatingmirnasinirritablebowelsyndromedetectedusingamultiplexedhighthroughputgeneexpressionplatform
AT sherwinleeanneb perturbationsofcirculatingmirnasinirritablebowelsyndromedetectedusingamultiplexedhighthroughputgeneexpressionplatform
AT wileyjohnw perturbationsofcirculatingmirnasinirritablebowelsyndromedetectedusingamultiplexedhighthroughputgeneexpressionplatform
AT hendersonwendya perturbationsofcirculatingmirnasinirritablebowelsyndromedetectedusingamultiplexedhighthroughputgeneexpressionplatform