Cargando…

The Viability of Hearing Protection Device Fit-Testing at Navy and Marine Corps Accession Points

INTRODUCTION: The viability of hearing protection device (HPD) verification (i.e., fit-testing) on a large scale was investigated to address this gap in a military accession environment. MATERIALS AND METHODS: Personal Attenuation Ratings (PARs) following self-fitted (SELF-Fit) HPDs were acquired fr...

Descripción completa

Detalles Bibliográficos
Autores principales: Federman, Jeremy, Duhon, Christon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5227010/
https://www.ncbi.nlm.nih.gov/pubmed/27991461
http://dx.doi.org/10.4103/1463-1741.195806
_version_ 1782493747981844480
author Federman, Jeremy
Duhon, Christon
author_facet Federman, Jeremy
Duhon, Christon
author_sort Federman, Jeremy
collection PubMed
description INTRODUCTION: The viability of hearing protection device (HPD) verification (i.e., fit-testing) on a large scale was investigated to address this gap in a military accession environment. MATERIALS AND METHODS: Personal Attenuation Ratings (PARs) following self-fitted (SELF-Fit) HPDs were acquired from 320 US Marine Corps training recruits (87.5% male, 12.5% female) across four test protocols (1-, 3-, 5-, and 7- frequency). SELF-Fit failures received follow-up to assess potential causes. Follow-up PARs were acquired (Experimenter fit [EXP-Fit], followed by Subject re-fit [SUB Re-Fit]). EXP-Fit was intended to provide a perception (dubbed “ear canal muscle memory”) of what a correctly fitted HPD should feel like. SUB Re-Fit was completed following EXP-Fit to determine whether a training recruit could duplicate EXP-Fit on her/his own without assistance. RESULTS: A one-way analysis of variance (ANOVA) (N=320) showed that SELF-Fit means differed significantly between protocols (P < 0.001). Post-hoc analyses showed that the 1-freq SELF-Fit mean was significantly lower than all other protocols (P < 0.03) by 5.6 dB or more. No difference was found between the multi-frequency protocols. For recruits who were followed up with EXP-Fit (n=79), across all protocols, a significant (P < 0.001) mean improvement of 25.68 dB (10.99) was found, but PARs did not differ (P = 0.99) between EXP-Fit protocols. For recruits in the 3-freq and 5-freq protocol groups who experienced all three PAR test methods (n=33), PAR methods differed (P < 0.001) but no method by protocol interaction was found (P = 0.46). Post hoc tests showed that both EXP-Fit and SUB Re-Fit had significantly better attenuation than SELF-Fit (P < 0.001), but no difference was found between EXPFit and SUB Re-Fit (P = 0.59). For SELF-Fit, the 1-freq protocol resulted in a 35% pass rate, whereas the 3-, 5-, and 7-freq protocols resulted in >60% pass rates. Results showed that once recruits experienced how HPDs should feel when inserted correctly, they were able to properly replicate the procedure with similar results to the expert fit suggesting “ear canal muscle memory” may be a viable training strategy concomitant with HPD verification. Fit-test duration was also measured to examine the tradeoff between results accuracy and time required to complete each protocol. DISCUSSION: Results from this study showed the critical importance of initial selection and fitting of HPDs followed by verification (i.e., fit-testing) at Navy and Marine Corps accession points. Achieving adequate protection from an HPD is fundamentally dependent on obtaining proper fit of the issued HPD as well as the quality of training recruits receive regarding HPD use.
format Online
Article
Text
id pubmed-5227010
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-52270102017-02-03 The Viability of Hearing Protection Device Fit-Testing at Navy and Marine Corps Accession Points Federman, Jeremy Duhon, Christon Noise Health Original Article INTRODUCTION: The viability of hearing protection device (HPD) verification (i.e., fit-testing) on a large scale was investigated to address this gap in a military accession environment. MATERIALS AND METHODS: Personal Attenuation Ratings (PARs) following self-fitted (SELF-Fit) HPDs were acquired from 320 US Marine Corps training recruits (87.5% male, 12.5% female) across four test protocols (1-, 3-, 5-, and 7- frequency). SELF-Fit failures received follow-up to assess potential causes. Follow-up PARs were acquired (Experimenter fit [EXP-Fit], followed by Subject re-fit [SUB Re-Fit]). EXP-Fit was intended to provide a perception (dubbed “ear canal muscle memory”) of what a correctly fitted HPD should feel like. SUB Re-Fit was completed following EXP-Fit to determine whether a training recruit could duplicate EXP-Fit on her/his own without assistance. RESULTS: A one-way analysis of variance (ANOVA) (N=320) showed that SELF-Fit means differed significantly between protocols (P < 0.001). Post-hoc analyses showed that the 1-freq SELF-Fit mean was significantly lower than all other protocols (P < 0.03) by 5.6 dB or more. No difference was found between the multi-frequency protocols. For recruits who were followed up with EXP-Fit (n=79), across all protocols, a significant (P < 0.001) mean improvement of 25.68 dB (10.99) was found, but PARs did not differ (P = 0.99) between EXP-Fit protocols. For recruits in the 3-freq and 5-freq protocol groups who experienced all three PAR test methods (n=33), PAR methods differed (P < 0.001) but no method by protocol interaction was found (P = 0.46). Post hoc tests showed that both EXP-Fit and SUB Re-Fit had significantly better attenuation than SELF-Fit (P < 0.001), but no difference was found between EXPFit and SUB Re-Fit (P = 0.59). For SELF-Fit, the 1-freq protocol resulted in a 35% pass rate, whereas the 3-, 5-, and 7-freq protocols resulted in >60% pass rates. Results showed that once recruits experienced how HPDs should feel when inserted correctly, they were able to properly replicate the procedure with similar results to the expert fit suggesting “ear canal muscle memory” may be a viable training strategy concomitant with HPD verification. Fit-test duration was also measured to examine the tradeoff between results accuracy and time required to complete each protocol. DISCUSSION: Results from this study showed the critical importance of initial selection and fitting of HPDs followed by verification (i.e., fit-testing) at Navy and Marine Corps accession points. Achieving adequate protection from an HPD is fundamentally dependent on obtaining proper fit of the issued HPD as well as the quality of training recruits receive regarding HPD use. Medknow Publications & Media Pvt Ltd 2016 /pmc/articles/PMC5227010/ /pubmed/27991461 http://dx.doi.org/10.4103/1463-1741.195806 Text en Copyright: © 2016 Noise & Health http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Federman, Jeremy
Duhon, Christon
The Viability of Hearing Protection Device Fit-Testing at Navy and Marine Corps Accession Points
title The Viability of Hearing Protection Device Fit-Testing at Navy and Marine Corps Accession Points
title_full The Viability of Hearing Protection Device Fit-Testing at Navy and Marine Corps Accession Points
title_fullStr The Viability of Hearing Protection Device Fit-Testing at Navy and Marine Corps Accession Points
title_full_unstemmed The Viability of Hearing Protection Device Fit-Testing at Navy and Marine Corps Accession Points
title_short The Viability of Hearing Protection Device Fit-Testing at Navy and Marine Corps Accession Points
title_sort viability of hearing protection device fit-testing at navy and marine corps accession points
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5227010/
https://www.ncbi.nlm.nih.gov/pubmed/27991461
http://dx.doi.org/10.4103/1463-1741.195806
work_keys_str_mv AT federmanjeremy theviabilityofhearingprotectiondevicefittestingatnavyandmarinecorpsaccessionpoints
AT duhonchriston theviabilityofhearingprotectiondevicefittestingatnavyandmarinecorpsaccessionpoints
AT federmanjeremy viabilityofhearingprotectiondevicefittestingatnavyandmarinecorpsaccessionpoints
AT duhonchriston viabilityofhearingprotectiondevicefittestingatnavyandmarinecorpsaccessionpoints