Cargando…

Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?

OBJECTIVES: Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible. The aim of the present study was...

Descripción completa

Detalles Bibliográficos
Autores principales: Acklin, Y. P., Zderic, I., Grechenig, S., Richards, R. G., Schmitz, P., Gueorguiev, B.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2017
Materias:
Hip
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5227056/
https://www.ncbi.nlm.nih.gov/pubmed/28057632
http://dx.doi.org/10.1302/2046-3758.61.BJR-2016-0261
_version_ 1782493751844798464
author Acklin, Y. P.
Zderic, I.
Grechenig, S.
Richards, R. G.
Schmitz, P.
Gueorguiev, B.
author_facet Acklin, Y. P.
Zderic, I.
Grechenig, S.
Richards, R. G.
Schmitz, P.
Gueorguiev, B.
author_sort Acklin, Y. P.
collection PubMed
description OBJECTIVES: Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible. The aim of the present study was to biomechanically compare retrograde intramedullary fixation of the superior pubic ramus using either one large- or two small-diameter screws. MATERIALS AND METHODS: A total of 12 human cadaveric hemipelvises were analysed in a matched pair study design. Bone mineral density of the specimens was 68 mgHA/cm(3) (standard deviation (sd) 52). The anterior pelvic ring fracture was fixed with either one 7.3 mm cannulated screw (Group 1) or two 3.5 mm pelvic cortex screws (Group 2). Progressively increasing cyclic axial loading was applied through the acetabulum. Relative movements in terms of interfragmentary displacement and gap angle at the fracture site were evaluated by means of optical movement tracking. The Wilcoxon signed-rank test was applied to identify significant differences between the groups RESULTS: Initial axial construct stiffness was not significantly different between the groups (p = 0.463). Interfragmentary displacement and gap angle at the fracture site were also not statistically significantly different between the groups throughout the evaluated cycles (p ⩾ 0.249). Similarly, cycles to failure were not statistically different between Group 1 (8438, sd 6968) and Group 2 (10 213, sd 10 334), p = 0.379. Failure mode in both groups was characterised by screw cutting through the cancellous bone. CONCLUSION: From a biomechanical point of view, pubic ramus stabilisation with either one large or two small fragment screw osteosynthesis is comparable in osteoporotic bone. However, the two-screw fixation technique is less demanding as the smaller screws deflect at the cortical margins. Cite this article: Y. P. Acklin, I. Zderic, S. Grechenig, R. G. Richards, P. Schmitz, B. Gueorguiev. Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density? Bone Joint Res 2017;6:8–13. DOI: 10.1302/2046-3758.61.BJR-2016-0261.
format Online
Article
Text
id pubmed-5227056
institution National Center for Biotechnology Information
language English
publishDate 2017
record_format MEDLINE/PubMed
spelling pubmed-52270562017-02-01 Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density? Acklin, Y. P. Zderic, I. Grechenig, S. Richards, R. G. Schmitz, P. Gueorguiev, B. Bone Joint Res Hip OBJECTIVES: Osteosynthesis of anterior pubic ramus fractures using one large-diameter screw can be challenging in terms of both surgical procedure and fixation stability. Small-fragment screws have the advantage of following the pelvic cortex and being more flexible. The aim of the present study was to biomechanically compare retrograde intramedullary fixation of the superior pubic ramus using either one large- or two small-diameter screws. MATERIALS AND METHODS: A total of 12 human cadaveric hemipelvises were analysed in a matched pair study design. Bone mineral density of the specimens was 68 mgHA/cm(3) (standard deviation (sd) 52). The anterior pelvic ring fracture was fixed with either one 7.3 mm cannulated screw (Group 1) or two 3.5 mm pelvic cortex screws (Group 2). Progressively increasing cyclic axial loading was applied through the acetabulum. Relative movements in terms of interfragmentary displacement and gap angle at the fracture site were evaluated by means of optical movement tracking. The Wilcoxon signed-rank test was applied to identify significant differences between the groups RESULTS: Initial axial construct stiffness was not significantly different between the groups (p = 0.463). Interfragmentary displacement and gap angle at the fracture site were also not statistically significantly different between the groups throughout the evaluated cycles (p ⩾ 0.249). Similarly, cycles to failure were not statistically different between Group 1 (8438, sd 6968) and Group 2 (10 213, sd 10 334), p = 0.379. Failure mode in both groups was characterised by screw cutting through the cancellous bone. CONCLUSION: From a biomechanical point of view, pubic ramus stabilisation with either one large or two small fragment screw osteosynthesis is comparable in osteoporotic bone. However, the two-screw fixation technique is less demanding as the smaller screws deflect at the cortical margins. Cite this article: Y. P. Acklin, I. Zderic, S. Grechenig, R. G. Richards, P. Schmitz, B. Gueorguiev. Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density? Bone Joint Res 2017;6:8–13. DOI: 10.1302/2046-3758.61.BJR-2016-0261. 2017-01-12 /pmc/articles/PMC5227056/ /pubmed/28057632 http://dx.doi.org/10.1302/2046-3758.61.BJR-2016-0261 Text en © 2017 Acklin et al. This is an open-access article distributed under the terms of the Creative Commons Attributions licence (CC-BY-NC), which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited.
spellingShingle Hip
Acklin, Y. P.
Zderic, I.
Grechenig, S.
Richards, R. G.
Schmitz, P.
Gueorguiev, B.
Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?
title Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?
title_full Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?
title_fullStr Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?
title_full_unstemmed Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?
title_short Are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?
title_sort are two retrograde 3.5 mm screws superior to one 7.3 mm screw for anterior pelvic ring fixation in bones with low bone mineral density?
topic Hip
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5227056/
https://www.ncbi.nlm.nih.gov/pubmed/28057632
http://dx.doi.org/10.1302/2046-3758.61.BJR-2016-0261
work_keys_str_mv AT acklinyp aretworetrograde35mmscrewssuperiortoone73mmscrewforanteriorpelvicringfixationinboneswithlowbonemineraldensity
AT zderici aretworetrograde35mmscrewssuperiortoone73mmscrewforanteriorpelvicringfixationinboneswithlowbonemineraldensity
AT grechenigs aretworetrograde35mmscrewssuperiortoone73mmscrewforanteriorpelvicringfixationinboneswithlowbonemineraldensity
AT richardsrg aretworetrograde35mmscrewssuperiortoone73mmscrewforanteriorpelvicringfixationinboneswithlowbonemineraldensity
AT schmitzp aretworetrograde35mmscrewssuperiortoone73mmscrewforanteriorpelvicringfixationinboneswithlowbonemineraldensity
AT gueorguievb aretworetrograde35mmscrewssuperiortoone73mmscrewforanteriorpelvicringfixationinboneswithlowbonemineraldensity