Cargando…

Design optimization of stent and its dilatation balloon using kriging surrogate model

BACKGROUND: Although stents have great success of treating cardiovascular disease, it actually undermined by the in-stent restenosis and their long-term fatigue failure. The geometry of stent affects its service performance and ultimately affects its fatigue life. Besides, improper length of balloon...

Descripción completa

Detalles Bibliográficos
Autores principales: Li, Hongxia, Liu, Tao, Wang, Minjie, Zhao, Danyang, Qiao, Aike, Wang, Xue, Gu, Junfeng, Li, Zheng, Zhu, Bao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5234108/
https://www.ncbi.nlm.nih.gov/pubmed/28086895
http://dx.doi.org/10.1186/s12938-016-0307-6
_version_ 1782494940857630720
author Li, Hongxia
Liu, Tao
Wang, Minjie
Zhao, Danyang
Qiao, Aike
Wang, Xue
Gu, Junfeng
Li, Zheng
Zhu, Bao
author_facet Li, Hongxia
Liu, Tao
Wang, Minjie
Zhao, Danyang
Qiao, Aike
Wang, Xue
Gu, Junfeng
Li, Zheng
Zhu, Bao
author_sort Li, Hongxia
collection PubMed
description BACKGROUND: Although stents have great success of treating cardiovascular disease, it actually undermined by the in-stent restenosis and their long-term fatigue failure. The geometry of stent affects its service performance and ultimately affects its fatigue life. Besides, improper length of balloon leads to transient mechanical injury to the vessel wall and in-stent restenosis. Conventional optimization method of stent and its dilatation balloon by comparing several designs and choosing the best one as the optimal design cannot find the global optimal design in the design space. In this study, an adaptive optimization method based on Kriging surrogate model was proposed to optimize the structure of stent and the length of stent dilatation balloon so as to prolong stent service life and improve the performance of stent. METHODS: A finite element simulation based optimization method combing with Kriging surrogate model is proposed to optimize geometries of stent and length of stent dilatation balloon step by step. Kriging surrogate model coupled with design of experiment method is employed to construct the approximate functional relationship between optimization objectives and design variables. Modified rectangular grid is used to select initial training samples in the design space. Expected improvement function is used to balance the local and global searches to find the global optimal result. Finite element method is adopted to simulate the free expansion of balloon-expandable stent and the expansion of stent in stenotic artery. The well-known Goodman diagram was used for the fatigue life prediction of stent, while dogboning effect was used for stent expansion performance measurement. As the real design cases, diamond-shaped stent and sv-shaped stent were studied to demonstrate how the proposed method can be harnessed to design and refine stent fatigue life and expansion performance computationally. RESULTS: The fatigue life and expansion performance of both the diamond-shaped stent and sv-shaped stent are designed and refined, respectively. (a) diamond-shaped stent: The shortest distance from the data points to the failure line in the Goodman diagram was increased by 22.39%, which indicated a safer service performance of the optimal stent. The dogboning effect was almost completely eliminated, which implies more uniform expansion of stent along its length. Simultaneously, radial elastic recoil (RR) at the proximal and distal ends was reduced by 40.98 and 35% respectively and foreshortening (FS) was also decreased by 1.75%. (b) sv-shaped stent: The shortest distance from the data point to the failure line in the Goodman diagram was increased by 15.91%. The dogboning effect was also completely eliminated, RR at the proximal and distal ends was reduced by 82.70 and 97.13%, respectively, and the FS was decreased by 16.81%. Numerical results showed that the fatigue life of both stents was refined and the comprehensive expansion performance of them was improved. CONCLUSIONS: This article presents an adaptive optimization method based on the Kriging surrogate model to optimize the structure of stents and the length of their dilatation balloon to prolong stents fatigue life and decreases the dogboning effect of stents during expansion process. Numerical results show that the adaptive optimization method based on Kriging surrogate model can effectively optimize the design of stents and the dilatation balloon. Further investigations containing more design goals and more effective multidisciplinary design optimization method are warranted.
format Online
Article
Text
id pubmed-5234108
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-52341082017-01-17 Design optimization of stent and its dilatation balloon using kriging surrogate model Li, Hongxia Liu, Tao Wang, Minjie Zhao, Danyang Qiao, Aike Wang, Xue Gu, Junfeng Li, Zheng Zhu, Bao Biomed Eng Online Research BACKGROUND: Although stents have great success of treating cardiovascular disease, it actually undermined by the in-stent restenosis and their long-term fatigue failure. The geometry of stent affects its service performance and ultimately affects its fatigue life. Besides, improper length of balloon leads to transient mechanical injury to the vessel wall and in-stent restenosis. Conventional optimization method of stent and its dilatation balloon by comparing several designs and choosing the best one as the optimal design cannot find the global optimal design in the design space. In this study, an adaptive optimization method based on Kriging surrogate model was proposed to optimize the structure of stent and the length of stent dilatation balloon so as to prolong stent service life and improve the performance of stent. METHODS: A finite element simulation based optimization method combing with Kriging surrogate model is proposed to optimize geometries of stent and length of stent dilatation balloon step by step. Kriging surrogate model coupled with design of experiment method is employed to construct the approximate functional relationship between optimization objectives and design variables. Modified rectangular grid is used to select initial training samples in the design space. Expected improvement function is used to balance the local and global searches to find the global optimal result. Finite element method is adopted to simulate the free expansion of balloon-expandable stent and the expansion of stent in stenotic artery. The well-known Goodman diagram was used for the fatigue life prediction of stent, while dogboning effect was used for stent expansion performance measurement. As the real design cases, diamond-shaped stent and sv-shaped stent were studied to demonstrate how the proposed method can be harnessed to design and refine stent fatigue life and expansion performance computationally. RESULTS: The fatigue life and expansion performance of both the diamond-shaped stent and sv-shaped stent are designed and refined, respectively. (a) diamond-shaped stent: The shortest distance from the data points to the failure line in the Goodman diagram was increased by 22.39%, which indicated a safer service performance of the optimal stent. The dogboning effect was almost completely eliminated, which implies more uniform expansion of stent along its length. Simultaneously, radial elastic recoil (RR) at the proximal and distal ends was reduced by 40.98 and 35% respectively and foreshortening (FS) was also decreased by 1.75%. (b) sv-shaped stent: The shortest distance from the data point to the failure line in the Goodman diagram was increased by 15.91%. The dogboning effect was also completely eliminated, RR at the proximal and distal ends was reduced by 82.70 and 97.13%, respectively, and the FS was decreased by 16.81%. Numerical results showed that the fatigue life of both stents was refined and the comprehensive expansion performance of them was improved. CONCLUSIONS: This article presents an adaptive optimization method based on the Kriging surrogate model to optimize the structure of stents and the length of their dilatation balloon to prolong stents fatigue life and decreases the dogboning effect of stents during expansion process. Numerical results show that the adaptive optimization method based on Kriging surrogate model can effectively optimize the design of stents and the dilatation balloon. Further investigations containing more design goals and more effective multidisciplinary design optimization method are warranted. BioMed Central 2017-01-11 /pmc/articles/PMC5234108/ /pubmed/28086895 http://dx.doi.org/10.1186/s12938-016-0307-6 Text en © The Author(s) 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Li, Hongxia
Liu, Tao
Wang, Minjie
Zhao, Danyang
Qiao, Aike
Wang, Xue
Gu, Junfeng
Li, Zheng
Zhu, Bao
Design optimization of stent and its dilatation balloon using kriging surrogate model
title Design optimization of stent and its dilatation balloon using kriging surrogate model
title_full Design optimization of stent and its dilatation balloon using kriging surrogate model
title_fullStr Design optimization of stent and its dilatation balloon using kriging surrogate model
title_full_unstemmed Design optimization of stent and its dilatation balloon using kriging surrogate model
title_short Design optimization of stent and its dilatation balloon using kriging surrogate model
title_sort design optimization of stent and its dilatation balloon using kriging surrogate model
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5234108/
https://www.ncbi.nlm.nih.gov/pubmed/28086895
http://dx.doi.org/10.1186/s12938-016-0307-6
work_keys_str_mv AT lihongxia designoptimizationofstentanditsdilatationballoonusingkrigingsurrogatemodel
AT liutao designoptimizationofstentanditsdilatationballoonusingkrigingsurrogatemodel
AT wangminjie designoptimizationofstentanditsdilatationballoonusingkrigingsurrogatemodel
AT zhaodanyang designoptimizationofstentanditsdilatationballoonusingkrigingsurrogatemodel
AT qiaoaike designoptimizationofstentanditsdilatationballoonusingkrigingsurrogatemodel
AT wangxue designoptimizationofstentanditsdilatationballoonusingkrigingsurrogatemodel
AT gujunfeng designoptimizationofstentanditsdilatationballoonusingkrigingsurrogatemodel
AT lizheng designoptimizationofstentanditsdilatationballoonusingkrigingsurrogatemodel
AT zhubao designoptimizationofstentanditsdilatationballoonusingkrigingsurrogatemodel