Cargando…
Quantitative Computed Tomography (QCT) derived Bone Mineral Density (BMD) in finite element studies: a review of the literature
BACKGROUND: Finite element modeling of human bone provides a powerful tool to evaluate a wide variety of outcomes in a highly repeatable and parametric manner. These models are most often derived from computed tomography data, with mechanical properties related to bone mineral density (BMD) from the...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5234499/ https://www.ncbi.nlm.nih.gov/pubmed/27943224 http://dx.doi.org/10.1186/s40634-016-0072-2 |
_version_ | 1782495003097956352 |
---|---|
author | Knowles, Nikolas K. Reeves, Jacob M. Ferreira, Louis M. |
author_facet | Knowles, Nikolas K. Reeves, Jacob M. Ferreira, Louis M. |
author_sort | Knowles, Nikolas K. |
collection | PubMed |
description | BACKGROUND: Finite element modeling of human bone provides a powerful tool to evaluate a wide variety of outcomes in a highly repeatable and parametric manner. These models are most often derived from computed tomography data, with mechanical properties related to bone mineral density (BMD) from the x-ray energy attenuation provided from this data. To increase accuracy, many researchers report the use of quantitative computed tomography (QCT), in which a calibration phantom is used during image acquisition to improve the estimation of BMD. Since model accuracy is dependent on the methods used in the calculation of BMD and density-mechanical property relationships, it is important to use relationships developed for the same anatomical location and using the same scanner settings, as these may impact model accuracy. The purpose of this literature review is to report the relationships used in the conversion of QCT equivalent density measures to ash, apparent, and/or tissue densities in recent finite element (FE) studies used in common density-modulus relationships. For studies reporting experimental validation, the validation metrics and results are presented. RESULTS: Of the studies reviewed, 29% reported the use of a dipotassium phosphate (K(2)HPO(4)) phantom, 47% a hydroxyapatite (HA) phantom, 13% did not report phantom type, 7% reported use of both K(2)HPO(4) and HA phantoms, and 4% alternate phantom types. Scanner type and/or settings were omitted or partially reported in 31% of studies. The majority of studies used densitometric and/or density-modulus relationships derived from different anatomical locations scanned in different scanners with different scanner settings. The methods used to derive various densitometric relationships are reported and recommendations are provided toward the standardization of reporting metrics. CONCLUSIONS: This review assessed the current state of QCT-based FE modeling with use of clinical scanners. It was found that previously developed densitometric relationships vary by anatomical location, scanner type and settings. Reporting of all parameters used when referring to previously developed relationships, or in the development of new relationships, may increase the accuracy and repeatability of future FE models. |
format | Online Article Text |
id | pubmed-5234499 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-52344992017-01-25 Quantitative Computed Tomography (QCT) derived Bone Mineral Density (BMD) in finite element studies: a review of the literature Knowles, Nikolas K. Reeves, Jacob M. Ferreira, Louis M. J Exp Orthop Review BACKGROUND: Finite element modeling of human bone provides a powerful tool to evaluate a wide variety of outcomes in a highly repeatable and parametric manner. These models are most often derived from computed tomography data, with mechanical properties related to bone mineral density (BMD) from the x-ray energy attenuation provided from this data. To increase accuracy, many researchers report the use of quantitative computed tomography (QCT), in which a calibration phantom is used during image acquisition to improve the estimation of BMD. Since model accuracy is dependent on the methods used in the calculation of BMD and density-mechanical property relationships, it is important to use relationships developed for the same anatomical location and using the same scanner settings, as these may impact model accuracy. The purpose of this literature review is to report the relationships used in the conversion of QCT equivalent density measures to ash, apparent, and/or tissue densities in recent finite element (FE) studies used in common density-modulus relationships. For studies reporting experimental validation, the validation metrics and results are presented. RESULTS: Of the studies reviewed, 29% reported the use of a dipotassium phosphate (K(2)HPO(4)) phantom, 47% a hydroxyapatite (HA) phantom, 13% did not report phantom type, 7% reported use of both K(2)HPO(4) and HA phantoms, and 4% alternate phantom types. Scanner type and/or settings were omitted or partially reported in 31% of studies. The majority of studies used densitometric and/or density-modulus relationships derived from different anatomical locations scanned in different scanners with different scanner settings. The methods used to derive various densitometric relationships are reported and recommendations are provided toward the standardization of reporting metrics. CONCLUSIONS: This review assessed the current state of QCT-based FE modeling with use of clinical scanners. It was found that previously developed densitometric relationships vary by anatomical location, scanner type and settings. Reporting of all parameters used when referring to previously developed relationships, or in the development of new relationships, may increase the accuracy and repeatability of future FE models. Springer Berlin Heidelberg 2016-12-09 /pmc/articles/PMC5234499/ /pubmed/27943224 http://dx.doi.org/10.1186/s40634-016-0072-2 Text en © The Author(s). 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Review Knowles, Nikolas K. Reeves, Jacob M. Ferreira, Louis M. Quantitative Computed Tomography (QCT) derived Bone Mineral Density (BMD) in finite element studies: a review of the literature |
title | Quantitative Computed Tomography (QCT)
derived Bone Mineral Density (BMD) in finite element studies: a review of the
literature |
title_full | Quantitative Computed Tomography (QCT)
derived Bone Mineral Density (BMD) in finite element studies: a review of the
literature |
title_fullStr | Quantitative Computed Tomography (QCT)
derived Bone Mineral Density (BMD) in finite element studies: a review of the
literature |
title_full_unstemmed | Quantitative Computed Tomography (QCT)
derived Bone Mineral Density (BMD) in finite element studies: a review of the
literature |
title_short | Quantitative Computed Tomography (QCT)
derived Bone Mineral Density (BMD) in finite element studies: a review of the
literature |
title_sort | quantitative computed tomography (qct)
derived bone mineral density (bmd) in finite element studies: a review of the
literature |
topic | Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5234499/ https://www.ncbi.nlm.nih.gov/pubmed/27943224 http://dx.doi.org/10.1186/s40634-016-0072-2 |
work_keys_str_mv | AT knowlesnikolask quantitativecomputedtomographyqctderivedbonemineraldensitybmdinfiniteelementstudiesareviewoftheliterature AT reevesjacobm quantitativecomputedtomographyqctderivedbonemineraldensitybmdinfiniteelementstudiesareviewoftheliterature AT ferreiralouism quantitativecomputedtomographyqctderivedbonemineraldensitybmdinfiniteelementstudiesareviewoftheliterature |