Cargando…

Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment

The tumor microenvironment is composed of cellular and stromal components such as tumor cells, mesenchymal cells, immune cells, cancer associated fibroblasts and the supporting extracellular matrix. The tumor microenvironment provides crucial support for growth and progression of tumor cells and aff...

Descripción completa

Detalles Bibliográficos
Autores principales: Holton, Angela Babetski, Sinatra, Francy L., Kreahling, Jenny, Conway, Amy J., Landis, David A., Altiok, Soner
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5235371/
https://www.ncbi.nlm.nih.gov/pubmed/28085924
http://dx.doi.org/10.1371/journal.pone.0169797
_version_ 1782495144022376448
author Holton, Angela Babetski
Sinatra, Francy L.
Kreahling, Jenny
Conway, Amy J.
Landis, David A.
Altiok, Soner
author_facet Holton, Angela Babetski
Sinatra, Francy L.
Kreahling, Jenny
Conway, Amy J.
Landis, David A.
Altiok, Soner
author_sort Holton, Angela Babetski
collection PubMed
description The tumor microenvironment is composed of cellular and stromal components such as tumor cells, mesenchymal cells, immune cells, cancer associated fibroblasts and the supporting extracellular matrix. The tumor microenvironment provides crucial support for growth and progression of tumor cells and affects tumor response to therapeutic interventions. To better understand tumor biology and to develop effective cancer therapeutic agents it is important to develop preclinical platforms that can faithfully recapitulate the tumor microenvironment and the complex interaction between the tumor and its surrounding stromal elements. Drug studies performed in vitro with conventional two-dimensional cancer cell line models do not optimally represent clinical drug response as they lack true tumor heterogeneity and are often performed in static culture conditions lacking stromal tumor components that significantly influence the metabolic activity and proliferation of cells. Recent microfluidic approaches aim to overcome such obstacles with the use of cell lines derived in artificial three-dimensional supportive gels or micro-chambers. However, absence of a true tumor microenvironment and full interstitial flow, leads to less than optimal evaluation of tumor response to drug treatment. Here we report a continuous perfusion microfluidic device coupled with microscopy and image analysis for the assessment of drug effects on intact fresh tumor tissue. We have demonstrated that fine needle aspirate biopsies obtained from patient-derived xenograft models of adenocarcinoma of the lung can successfully be analyzed for their response to ex vivo drug treatment within this biopsy trapping microfluidic device, wherein a protein kinase C inhibitor, staurosporine, was used to assess tumor cell death as a proof of principle. This approach has the potential to study tumor tissue within its intact microenvironment to better understand tumor response to drug treatments and eventually to choose the most effective drug and drug combination for individual patients in a cost effective and timely manner.
format Online
Article
Text
id pubmed-5235371
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-52353712017-02-06 Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment Holton, Angela Babetski Sinatra, Francy L. Kreahling, Jenny Conway, Amy J. Landis, David A. Altiok, Soner PLoS One Research Article The tumor microenvironment is composed of cellular and stromal components such as tumor cells, mesenchymal cells, immune cells, cancer associated fibroblasts and the supporting extracellular matrix. The tumor microenvironment provides crucial support for growth and progression of tumor cells and affects tumor response to therapeutic interventions. To better understand tumor biology and to develop effective cancer therapeutic agents it is important to develop preclinical platforms that can faithfully recapitulate the tumor microenvironment and the complex interaction between the tumor and its surrounding stromal elements. Drug studies performed in vitro with conventional two-dimensional cancer cell line models do not optimally represent clinical drug response as they lack true tumor heterogeneity and are often performed in static culture conditions lacking stromal tumor components that significantly influence the metabolic activity and proliferation of cells. Recent microfluidic approaches aim to overcome such obstacles with the use of cell lines derived in artificial three-dimensional supportive gels or micro-chambers. However, absence of a true tumor microenvironment and full interstitial flow, leads to less than optimal evaluation of tumor response to drug treatment. Here we report a continuous perfusion microfluidic device coupled with microscopy and image analysis for the assessment of drug effects on intact fresh tumor tissue. We have demonstrated that fine needle aspirate biopsies obtained from patient-derived xenograft models of adenocarcinoma of the lung can successfully be analyzed for their response to ex vivo drug treatment within this biopsy trapping microfluidic device, wherein a protein kinase C inhibitor, staurosporine, was used to assess tumor cell death as a proof of principle. This approach has the potential to study tumor tissue within its intact microenvironment to better understand tumor response to drug treatments and eventually to choose the most effective drug and drug combination for individual patients in a cost effective and timely manner. Public Library of Science 2017-01-13 /pmc/articles/PMC5235371/ /pubmed/28085924 http://dx.doi.org/10.1371/journal.pone.0169797 Text en © 2017 Holton et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Holton, Angela Babetski
Sinatra, Francy L.
Kreahling, Jenny
Conway, Amy J.
Landis, David A.
Altiok, Soner
Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment
title Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment
title_full Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment
title_fullStr Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment
title_full_unstemmed Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment
title_short Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment
title_sort microfluidic biopsy trapping device for the real-time monitoring of tumor microenvironment
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5235371/
https://www.ncbi.nlm.nih.gov/pubmed/28085924
http://dx.doi.org/10.1371/journal.pone.0169797
work_keys_str_mv AT holtonangelababetski microfluidicbiopsytrappingdevicefortherealtimemonitoringoftumormicroenvironment
AT sinatrafrancyl microfluidicbiopsytrappingdevicefortherealtimemonitoringoftumormicroenvironment
AT kreahlingjenny microfluidicbiopsytrappingdevicefortherealtimemonitoringoftumormicroenvironment
AT conwayamyj microfluidicbiopsytrappingdevicefortherealtimemonitoringoftumormicroenvironment
AT landisdavida microfluidicbiopsytrappingdevicefortherealtimemonitoringoftumormicroenvironment
AT altioksoner microfluidicbiopsytrappingdevicefortherealtimemonitoringoftumormicroenvironment