Cargando…
Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment
The tumor microenvironment is composed of cellular and stromal components such as tumor cells, mesenchymal cells, immune cells, cancer associated fibroblasts and the supporting extracellular matrix. The tumor microenvironment provides crucial support for growth and progression of tumor cells and aff...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5235371/ https://www.ncbi.nlm.nih.gov/pubmed/28085924 http://dx.doi.org/10.1371/journal.pone.0169797 |
_version_ | 1782495144022376448 |
---|---|
author | Holton, Angela Babetski Sinatra, Francy L. Kreahling, Jenny Conway, Amy J. Landis, David A. Altiok, Soner |
author_facet | Holton, Angela Babetski Sinatra, Francy L. Kreahling, Jenny Conway, Amy J. Landis, David A. Altiok, Soner |
author_sort | Holton, Angela Babetski |
collection | PubMed |
description | The tumor microenvironment is composed of cellular and stromal components such as tumor cells, mesenchymal cells, immune cells, cancer associated fibroblasts and the supporting extracellular matrix. The tumor microenvironment provides crucial support for growth and progression of tumor cells and affects tumor response to therapeutic interventions. To better understand tumor biology and to develop effective cancer therapeutic agents it is important to develop preclinical platforms that can faithfully recapitulate the tumor microenvironment and the complex interaction between the tumor and its surrounding stromal elements. Drug studies performed in vitro with conventional two-dimensional cancer cell line models do not optimally represent clinical drug response as they lack true tumor heterogeneity and are often performed in static culture conditions lacking stromal tumor components that significantly influence the metabolic activity and proliferation of cells. Recent microfluidic approaches aim to overcome such obstacles with the use of cell lines derived in artificial three-dimensional supportive gels or micro-chambers. However, absence of a true tumor microenvironment and full interstitial flow, leads to less than optimal evaluation of tumor response to drug treatment. Here we report a continuous perfusion microfluidic device coupled with microscopy and image analysis for the assessment of drug effects on intact fresh tumor tissue. We have demonstrated that fine needle aspirate biopsies obtained from patient-derived xenograft models of adenocarcinoma of the lung can successfully be analyzed for their response to ex vivo drug treatment within this biopsy trapping microfluidic device, wherein a protein kinase C inhibitor, staurosporine, was used to assess tumor cell death as a proof of principle. This approach has the potential to study tumor tissue within its intact microenvironment to better understand tumor response to drug treatments and eventually to choose the most effective drug and drug combination for individual patients in a cost effective and timely manner. |
format | Online Article Text |
id | pubmed-5235371 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-52353712017-02-06 Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment Holton, Angela Babetski Sinatra, Francy L. Kreahling, Jenny Conway, Amy J. Landis, David A. Altiok, Soner PLoS One Research Article The tumor microenvironment is composed of cellular and stromal components such as tumor cells, mesenchymal cells, immune cells, cancer associated fibroblasts and the supporting extracellular matrix. The tumor microenvironment provides crucial support for growth and progression of tumor cells and affects tumor response to therapeutic interventions. To better understand tumor biology and to develop effective cancer therapeutic agents it is important to develop preclinical platforms that can faithfully recapitulate the tumor microenvironment and the complex interaction between the tumor and its surrounding stromal elements. Drug studies performed in vitro with conventional two-dimensional cancer cell line models do not optimally represent clinical drug response as they lack true tumor heterogeneity and are often performed in static culture conditions lacking stromal tumor components that significantly influence the metabolic activity and proliferation of cells. Recent microfluidic approaches aim to overcome such obstacles with the use of cell lines derived in artificial three-dimensional supportive gels or micro-chambers. However, absence of a true tumor microenvironment and full interstitial flow, leads to less than optimal evaluation of tumor response to drug treatment. Here we report a continuous perfusion microfluidic device coupled with microscopy and image analysis for the assessment of drug effects on intact fresh tumor tissue. We have demonstrated that fine needle aspirate biopsies obtained from patient-derived xenograft models of adenocarcinoma of the lung can successfully be analyzed for their response to ex vivo drug treatment within this biopsy trapping microfluidic device, wherein a protein kinase C inhibitor, staurosporine, was used to assess tumor cell death as a proof of principle. This approach has the potential to study tumor tissue within its intact microenvironment to better understand tumor response to drug treatments and eventually to choose the most effective drug and drug combination for individual patients in a cost effective and timely manner. Public Library of Science 2017-01-13 /pmc/articles/PMC5235371/ /pubmed/28085924 http://dx.doi.org/10.1371/journal.pone.0169797 Text en © 2017 Holton et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Holton, Angela Babetski Sinatra, Francy L. Kreahling, Jenny Conway, Amy J. Landis, David A. Altiok, Soner Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment |
title | Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment |
title_full | Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment |
title_fullStr | Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment |
title_full_unstemmed | Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment |
title_short | Microfluidic Biopsy Trapping Device for the Real-Time Monitoring of Tumor Microenvironment |
title_sort | microfluidic biopsy trapping device for the real-time monitoring of tumor microenvironment |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5235371/ https://www.ncbi.nlm.nih.gov/pubmed/28085924 http://dx.doi.org/10.1371/journal.pone.0169797 |
work_keys_str_mv | AT holtonangelababetski microfluidicbiopsytrappingdevicefortherealtimemonitoringoftumormicroenvironment AT sinatrafrancyl microfluidicbiopsytrappingdevicefortherealtimemonitoringoftumormicroenvironment AT kreahlingjenny microfluidicbiopsytrappingdevicefortherealtimemonitoringoftumormicroenvironment AT conwayamyj microfluidicbiopsytrappingdevicefortherealtimemonitoringoftumormicroenvironment AT landisdavida microfluidicbiopsytrappingdevicefortherealtimemonitoringoftumormicroenvironment AT altioksoner microfluidicbiopsytrappingdevicefortherealtimemonitoringoftumormicroenvironment |