Cargando…
Diagnostic accuracy of transient elastography (FibroScan) in detection of esophageal varices in patients with cirrhosis: A meta-analysis
AIM: To investigate the diagnostic accuracy of FibroScan (FS) in detecting esophageal varices (EV) in cirrhotic patients. METHODS: Through a systemic literature search of multiple databases, we reviewed 15 studies using endoscopy as a reference standard, with the data necessary to calculate pooled s...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Baishideng Publishing Group Inc
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5236514/ https://www.ncbi.nlm.nih.gov/pubmed/28127208 http://dx.doi.org/10.3748/wjg.v23.i2.345 |
_version_ | 1782495360872087552 |
---|---|
author | Pu, Ke Shi, Jing-Hong Wang, Xu Tang, Qian Wang, Xin-Jie Tang, Kai-Lin Long, Zhong-Qi Hu, Xing-Sheng |
author_facet | Pu, Ke Shi, Jing-Hong Wang, Xu Tang, Qian Wang, Xin-Jie Tang, Kai-Lin Long, Zhong-Qi Hu, Xing-Sheng |
author_sort | Pu, Ke |
collection | PubMed |
description | AIM: To investigate the diagnostic accuracy of FibroScan (FS) in detecting esophageal varices (EV) in cirrhotic patients. METHODS: Through a systemic literature search of multiple databases, we reviewed 15 studies using endoscopy as a reference standard, with the data necessary to calculate pooled sensitivity (SEN) and specificity (SPE), positive and negative LR, diagnostic odds ratio (DOR) and area under receiver operating characteristics (AUROC). The quality of the studies was rated by the Quality Assessment of Diagnostic Accuracy studies-2 tool. Clinical utility of FS for EV was evaluated by a Fagan plot. Heterogeneity was explored using meta-regression and subgroup analysis. All statistical analyses were conducted via Stata12.0, MetaDisc1.4 and RevMan5. RESULTS: In 15 studies (n = 2697), FS detected the presence of EV with the summary sensitivities of 84% (95%CI: 81.0%-86.0%), specificities of 62% (95%CI: 58.0%- 66.0%), a positive LR of 2.3 (95%CI: 1.81-2.94), a negative LR of 0.26 (95%CI: 0.19-0.35), a DOR of 9.33 (95%CI: 5.84-14.92) and an AUROC of 0.8262. FS diagnosed the presence of large EV with the pooled SEN of 0.78 (95%CI: 75.0%-81.0%), SPE of 0.76 (95%CI: 73.0%-78.0%), a positive and negative LR of 3.03 (95%CI: 2.38-3.86) and 0.30 (95%CI: 0.23-0.39) respectively, a summary diagnostic OR of 10.69 (95%CI: 6.81-16.78), and an AUROC of 0.8321. A meta-regression and subgroup analysis indicated different etiology could serve as a potential source of heterogeneity in the diagnosis of the presence of EV group. A Deek’s funnel plot suggested a low probability for publication bias. CONCLUSION: Using FS to measure liver stiffness cannot provide high accuracy for the size of EV due to the various cutoff and different etiologies. These limitations preclude widespread use in clinical practice at this time; therefore, the results should be interpreted cautiously given its SEN and SPE. |
format | Online Article Text |
id | pubmed-5236514 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Baishideng Publishing Group Inc |
record_format | MEDLINE/PubMed |
spelling | pubmed-52365142017-01-26 Diagnostic accuracy of transient elastography (FibroScan) in detection of esophageal varices in patients with cirrhosis: A meta-analysis Pu, Ke Shi, Jing-Hong Wang, Xu Tang, Qian Wang, Xin-Jie Tang, Kai-Lin Long, Zhong-Qi Hu, Xing-Sheng World J Gastroenterol Meta-Analysis AIM: To investigate the diagnostic accuracy of FibroScan (FS) in detecting esophageal varices (EV) in cirrhotic patients. METHODS: Through a systemic literature search of multiple databases, we reviewed 15 studies using endoscopy as a reference standard, with the data necessary to calculate pooled sensitivity (SEN) and specificity (SPE), positive and negative LR, diagnostic odds ratio (DOR) and area under receiver operating characteristics (AUROC). The quality of the studies was rated by the Quality Assessment of Diagnostic Accuracy studies-2 tool. Clinical utility of FS for EV was evaluated by a Fagan plot. Heterogeneity was explored using meta-regression and subgroup analysis. All statistical analyses were conducted via Stata12.0, MetaDisc1.4 and RevMan5. RESULTS: In 15 studies (n = 2697), FS detected the presence of EV with the summary sensitivities of 84% (95%CI: 81.0%-86.0%), specificities of 62% (95%CI: 58.0%- 66.0%), a positive LR of 2.3 (95%CI: 1.81-2.94), a negative LR of 0.26 (95%CI: 0.19-0.35), a DOR of 9.33 (95%CI: 5.84-14.92) and an AUROC of 0.8262. FS diagnosed the presence of large EV with the pooled SEN of 0.78 (95%CI: 75.0%-81.0%), SPE of 0.76 (95%CI: 73.0%-78.0%), a positive and negative LR of 3.03 (95%CI: 2.38-3.86) and 0.30 (95%CI: 0.23-0.39) respectively, a summary diagnostic OR of 10.69 (95%CI: 6.81-16.78), and an AUROC of 0.8321. A meta-regression and subgroup analysis indicated different etiology could serve as a potential source of heterogeneity in the diagnosis of the presence of EV group. A Deek’s funnel plot suggested a low probability for publication bias. CONCLUSION: Using FS to measure liver stiffness cannot provide high accuracy for the size of EV due to the various cutoff and different etiologies. These limitations preclude widespread use in clinical practice at this time; therefore, the results should be interpreted cautiously given its SEN and SPE. Baishideng Publishing Group Inc 2017-01-14 2017-01-14 /pmc/articles/PMC5236514/ /pubmed/28127208 http://dx.doi.org/10.3748/wjg.v23.i2.345 Text en ©The Author(s) 2017. Published by Baishideng Publishing Group Inc. All rights reserved. http://creativecommons.org/licenses/by-nc/4.0/ This article is an open-access article which was selected by an in-house editor and fully peer-reviewed by external reviewers. It is distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. |
spellingShingle | Meta-Analysis Pu, Ke Shi, Jing-Hong Wang, Xu Tang, Qian Wang, Xin-Jie Tang, Kai-Lin Long, Zhong-Qi Hu, Xing-Sheng Diagnostic accuracy of transient elastography (FibroScan) in detection of esophageal varices in patients with cirrhosis: A meta-analysis |
title | Diagnostic accuracy of transient elastography (FibroScan) in detection of esophageal varices in patients with cirrhosis: A meta-analysis |
title_full | Diagnostic accuracy of transient elastography (FibroScan) in detection of esophageal varices in patients with cirrhosis: A meta-analysis |
title_fullStr | Diagnostic accuracy of transient elastography (FibroScan) in detection of esophageal varices in patients with cirrhosis: A meta-analysis |
title_full_unstemmed | Diagnostic accuracy of transient elastography (FibroScan) in detection of esophageal varices in patients with cirrhosis: A meta-analysis |
title_short | Diagnostic accuracy of transient elastography (FibroScan) in detection of esophageal varices in patients with cirrhosis: A meta-analysis |
title_sort | diagnostic accuracy of transient elastography (fibroscan) in detection of esophageal varices in patients with cirrhosis: a meta-analysis |
topic | Meta-Analysis |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5236514/ https://www.ncbi.nlm.nih.gov/pubmed/28127208 http://dx.doi.org/10.3748/wjg.v23.i2.345 |
work_keys_str_mv | AT puke diagnosticaccuracyoftransientelastographyfibroscanindetectionofesophagealvaricesinpatientswithcirrhosisametaanalysis AT shijinghong diagnosticaccuracyoftransientelastographyfibroscanindetectionofesophagealvaricesinpatientswithcirrhosisametaanalysis AT wangxu diagnosticaccuracyoftransientelastographyfibroscanindetectionofesophagealvaricesinpatientswithcirrhosisametaanalysis AT tangqian diagnosticaccuracyoftransientelastographyfibroscanindetectionofesophagealvaricesinpatientswithcirrhosisametaanalysis AT wangxinjie diagnosticaccuracyoftransientelastographyfibroscanindetectionofesophagealvaricesinpatientswithcirrhosisametaanalysis AT tangkailin diagnosticaccuracyoftransientelastographyfibroscanindetectionofesophagealvaricesinpatientswithcirrhosisametaanalysis AT longzhongqi diagnosticaccuracyoftransientelastographyfibroscanindetectionofesophagealvaricesinpatientswithcirrhosisametaanalysis AT huxingsheng diagnosticaccuracyoftransientelastographyfibroscanindetectionofesophagealvaricesinpatientswithcirrhosisametaanalysis |