Cargando…
Myocardial T1 and T2 Mapping: Techniques and Clinical Applications
Cardiac magnetic resonance (CMR) imaging is widely used in various medical fields related to cardiovascular diseases. Rapid technological innovations in magnetic resonance imaging in recent times have resulted in the development of new techniques for CMR imaging. T1 and T2 image mapping sequences en...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Radiology
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5240500/ https://www.ncbi.nlm.nih.gov/pubmed/28096723 http://dx.doi.org/10.3348/kjr.2017.18.1.113 |
_version_ | 1782496083118653440 |
---|---|
author | Kim, Pan Ki Hong, Yoo Jin Im, Dong Jin Suh, Young Joo Park, Chul Hwan Kim, Jin Young Chang, Suyon Lee, Hye-Jeong Hur, Jin Kim, Young Jin Choi, Byoung Wook |
author_facet | Kim, Pan Ki Hong, Yoo Jin Im, Dong Jin Suh, Young Joo Park, Chul Hwan Kim, Jin Young Chang, Suyon Lee, Hye-Jeong Hur, Jin Kim, Young Jin Choi, Byoung Wook |
author_sort | Kim, Pan Ki |
collection | PubMed |
description | Cardiac magnetic resonance (CMR) imaging is widely used in various medical fields related to cardiovascular diseases. Rapid technological innovations in magnetic resonance imaging in recent times have resulted in the development of new techniques for CMR imaging. T1 and T2 image mapping sequences enable the direct quantification of T1, T2, and extracellular volume fraction (ECV) values of the myocardium, leading to the progressive integration of these sequences into routine CMR settings. Currently, T1, T2, and ECV values are being recognized as not only robust biomarkers for diagnosis of cardiomyopathies, but also predictive factors for treatment monitoring and prognosis. In this study, we have reviewed various T1 and T2 mapping sequence techniques and their clinical applications. |
format | Online Article Text |
id | pubmed-5240500 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | The Korean Society of Radiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-52405002017-01-17 Myocardial T1 and T2 Mapping: Techniques and Clinical Applications Kim, Pan Ki Hong, Yoo Jin Im, Dong Jin Suh, Young Joo Park, Chul Hwan Kim, Jin Young Chang, Suyon Lee, Hye-Jeong Hur, Jin Kim, Young Jin Choi, Byoung Wook Korean J Radiol Cardiovascular Imaging Cardiac magnetic resonance (CMR) imaging is widely used in various medical fields related to cardiovascular diseases. Rapid technological innovations in magnetic resonance imaging in recent times have resulted in the development of new techniques for CMR imaging. T1 and T2 image mapping sequences enable the direct quantification of T1, T2, and extracellular volume fraction (ECV) values of the myocardium, leading to the progressive integration of these sequences into routine CMR settings. Currently, T1, T2, and ECV values are being recognized as not only robust biomarkers for diagnosis of cardiomyopathies, but also predictive factors for treatment monitoring and prognosis. In this study, we have reviewed various T1 and T2 mapping sequence techniques and their clinical applications. The Korean Society of Radiology 2017 2017-01-05 /pmc/articles/PMC5240500/ /pubmed/28096723 http://dx.doi.org/10.3348/kjr.2017.18.1.113 Text en Copyright © 2017 The Korean Society of Radiology http://creativecommons.org/licenses/by-nc/3.0/ This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Cardiovascular Imaging Kim, Pan Ki Hong, Yoo Jin Im, Dong Jin Suh, Young Joo Park, Chul Hwan Kim, Jin Young Chang, Suyon Lee, Hye-Jeong Hur, Jin Kim, Young Jin Choi, Byoung Wook Myocardial T1 and T2 Mapping: Techniques and Clinical Applications |
title | Myocardial T1 and T2 Mapping: Techniques and Clinical Applications |
title_full | Myocardial T1 and T2 Mapping: Techniques and Clinical Applications |
title_fullStr | Myocardial T1 and T2 Mapping: Techniques and Clinical Applications |
title_full_unstemmed | Myocardial T1 and T2 Mapping: Techniques and Clinical Applications |
title_short | Myocardial T1 and T2 Mapping: Techniques and Clinical Applications |
title_sort | myocardial t1 and t2 mapping: techniques and clinical applications |
topic | Cardiovascular Imaging |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5240500/ https://www.ncbi.nlm.nih.gov/pubmed/28096723 http://dx.doi.org/10.3348/kjr.2017.18.1.113 |
work_keys_str_mv | AT kimpanki myocardialt1andt2mappingtechniquesandclinicalapplications AT hongyoojin myocardialt1andt2mappingtechniquesandclinicalapplications AT imdongjin myocardialt1andt2mappingtechniquesandclinicalapplications AT suhyoungjoo myocardialt1andt2mappingtechniquesandclinicalapplications AT parkchulhwan myocardialt1andt2mappingtechniquesandclinicalapplications AT kimjinyoung myocardialt1andt2mappingtechniquesandclinicalapplications AT changsuyon myocardialt1andt2mappingtechniquesandclinicalapplications AT leehyejeong myocardialt1andt2mappingtechniquesandclinicalapplications AT hurjin myocardialt1andt2mappingtechniquesandclinicalapplications AT kimyoungjin myocardialt1andt2mappingtechniquesandclinicalapplications AT choibyoungwook myocardialt1andt2mappingtechniquesandclinicalapplications |