Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases

Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I....

Descripción completa

Detalles Bibliográficos
Autores principales: Kuwelker, Saatchi Mahesh, Shetty, Devi Prasad, Dalvi, Bharat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5241847/
https://www.ncbi.nlm.nih.gov/pubmed/28163430
http://dx.doi.org/10.4103/0974-2069.197052
_version_ 1782496250047758336
author Kuwelker, Saatchi Mahesh
Shetty, Devi Prasad
Dalvi, Bharat
author_facet Kuwelker, Saatchi Mahesh
Shetty, Devi Prasad
Dalvi, Bharat
author_sort Kuwelker, Saatchi Mahesh
collection PubMed
description Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with severe tricuspid regurgitation (TR) 6 weeks and 3 months following the device closure. They underwent surgical repair with patch augmentation of the TV leaflets. Postoperatively, both are asymptomatic with a mild residual TR.
format Online
Article
Text
id pubmed-5241847
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-52418472017-02-03 Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases Kuwelker, Saatchi Mahesh Shetty, Devi Prasad Dalvi, Bharat Ann Pediatr Cardiol Case Report Tricuspid valve (TV) injury following transcatheter closure of perimembranous ventricular septal defect (PMVSD) with Amplatzer ductal occluder I (ADO I), requiring surgical repair, is rare. We report two cases of TV tear involving the anterior and septal leaflets following PMVSD closure using ADO I. In both the patients, the subvalvular apparatus remained unaffected. The patients presented with severe tricuspid regurgitation (TR) 6 weeks and 3 months following the device closure. They underwent surgical repair with patch augmentation of the TV leaflets. Postoperatively, both are asymptomatic with a mild residual TR. Medknow Publications & Media Pvt Ltd 2017 /pmc/articles/PMC5241847/ /pubmed/28163430 http://dx.doi.org/10.4103/0974-2069.197052 Text en Copyright: © Annals of Pediatric Cardiology http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Case Report
Kuwelker, Saatchi Mahesh
Shetty, Devi Prasad
Dalvi, Bharat
Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases
title Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases
title_full Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases
title_fullStr Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases
title_full_unstemmed Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases
title_short Surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using Amplatzer duct occluder I: Report of two cases
title_sort surgical repair of tricuspid valve leaflet tear following percutaneous closure of perimembranous ventricular septal defect using amplatzer duct occluder i: report of two cases
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5241847/
https://www.ncbi.nlm.nih.gov/pubmed/28163430
http://dx.doi.org/10.4103/0974-2069.197052
work_keys_str_mv AT kuwelkersaatchimahesh surgicalrepairoftricuspidvalveleaflettearfollowingpercutaneousclosureofperimembranousventricularseptaldefectusingamplatzerductoccluderireportoftwocases
AT shettydeviprasad surgicalrepairoftricuspidvalveleaflettearfollowingpercutaneousclosureofperimembranousventricularseptaldefectusingamplatzerductoccluderireportoftwocases
AT dalvibharat surgicalrepairoftricuspidvalveleaflettearfollowingpercutaneousclosureofperimembranousventricularseptaldefectusingamplatzerductoccluderireportoftwocases