Cargando…
Telescoping Dual Covered Stent Graft Construct for Endovascular Treatment of a Giant Extracranial Carotid Artery Pseudoaneurysm
Large pseudoaneurysms which compress the parent vessel are challenging lesions to successfully treat with endovascular therapy. We describe the endovascular treatment of a giant extracranial carotid artery (ECCA) pseudoaneurysm resulting in substantial mass effect on the common carotid artery (CCA)...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5244037/ https://www.ncbi.nlm.nih.gov/pubmed/28163519 http://dx.doi.org/10.4103/0976-3147.196441 |
_version_ | 1782496625717936128 |
---|---|
author | Ding, Dale Starke, Robert M. Moriarty, Maurice Brew, Stefan |
author_facet | Ding, Dale Starke, Robert M. Moriarty, Maurice Brew, Stefan |
author_sort | Ding, Dale |
collection | PubMed |
description | Large pseudoaneurysms which compress the parent vessel are challenging lesions to successfully treat with endovascular therapy. We describe the endovascular treatment of a giant extracranial carotid artery (ECCA) pseudoaneurysm resulting in substantial mass effect on the common carotid artery (CCA) bifurcation using a telescoping dual covered stent graft construct. A 56-year-old male was diagnosed with an 8.5 cm × 13 cm pseudoaneurysm arising from the left CCA bifurcation, which was causing luminal narrowing of the CCA and proximal internal carotid artery (ICA). The patient underwent endovascular intervention, during which a balloon-expandable covered stent was deployed within a heparin-bonded covered stent, such that the overall construct spanned from the CCA to the lower cervical ICA. The employment of a telescoping dual covered stent technique can successfully treat appropriately selected patients with large or giant ECCA pseudoaneurysms, with the concomitant goals of excluding the pseudoaneurysm and restoring the luminal caliber of the parent artery. |
format | Online Article Text |
id | pubmed-5244037 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-52440372017-02-03 Telescoping Dual Covered Stent Graft Construct for Endovascular Treatment of a Giant Extracranial Carotid Artery Pseudoaneurysm Ding, Dale Starke, Robert M. Moriarty, Maurice Brew, Stefan J Neurosci Rural Pract Case Report Large pseudoaneurysms which compress the parent vessel are challenging lesions to successfully treat with endovascular therapy. We describe the endovascular treatment of a giant extracranial carotid artery (ECCA) pseudoaneurysm resulting in substantial mass effect on the common carotid artery (CCA) bifurcation using a telescoping dual covered stent graft construct. A 56-year-old male was diagnosed with an 8.5 cm × 13 cm pseudoaneurysm arising from the left CCA bifurcation, which was causing luminal narrowing of the CCA and proximal internal carotid artery (ICA). The patient underwent endovascular intervention, during which a balloon-expandable covered stent was deployed within a heparin-bonded covered stent, such that the overall construct spanned from the CCA to the lower cervical ICA. The employment of a telescoping dual covered stent technique can successfully treat appropriately selected patients with large or giant ECCA pseudoaneurysms, with the concomitant goals of excluding the pseudoaneurysm and restoring the luminal caliber of the parent artery. Medknow Publications & Media Pvt Ltd 2016-12 /pmc/articles/PMC5244037/ /pubmed/28163519 http://dx.doi.org/10.4103/0976-3147.196441 Text en Copyright: © Journal of Neurosciences in Rural Practice http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms. |
spellingShingle | Case Report Ding, Dale Starke, Robert M. Moriarty, Maurice Brew, Stefan Telescoping Dual Covered Stent Graft Construct for Endovascular Treatment of a Giant Extracranial Carotid Artery Pseudoaneurysm |
title | Telescoping Dual Covered Stent Graft Construct for Endovascular Treatment of a Giant Extracranial Carotid Artery Pseudoaneurysm |
title_full | Telescoping Dual Covered Stent Graft Construct for Endovascular Treatment of a Giant Extracranial Carotid Artery Pseudoaneurysm |
title_fullStr | Telescoping Dual Covered Stent Graft Construct for Endovascular Treatment of a Giant Extracranial Carotid Artery Pseudoaneurysm |
title_full_unstemmed | Telescoping Dual Covered Stent Graft Construct for Endovascular Treatment of a Giant Extracranial Carotid Artery Pseudoaneurysm |
title_short | Telescoping Dual Covered Stent Graft Construct for Endovascular Treatment of a Giant Extracranial Carotid Artery Pseudoaneurysm |
title_sort | telescoping dual covered stent graft construct for endovascular treatment of a giant extracranial carotid artery pseudoaneurysm |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5244037/ https://www.ncbi.nlm.nih.gov/pubmed/28163519 http://dx.doi.org/10.4103/0976-3147.196441 |
work_keys_str_mv | AT dingdale telescopingdualcoveredstentgraftconstructforendovasculartreatmentofagiantextracranialcarotidarterypseudoaneurysm AT starkerobertm telescopingdualcoveredstentgraftconstructforendovasculartreatmentofagiantextracranialcarotidarterypseudoaneurysm AT moriartymaurice telescopingdualcoveredstentgraftconstructforendovasculartreatmentofagiantextracranialcarotidarterypseudoaneurysm AT brewstefan telescopingdualcoveredstentgraftconstructforendovasculartreatmentofagiantextracranialcarotidarterypseudoaneurysm |