Cargando…

Results after Cementless Medial Oxford Unicompartmental Knee Replacement - Incidence of Radiolucent Lines

PURPOSE: Tibial radiolucent lines (RL) are commonly seen in cemented unicompartmental knee replacement (UKR). In the postoperative course, they can be misinterpreted as signs of loosening, thus leading to unnecessary revision. Since 2004, a cementless OUKR is available. First studies and registry da...

Descripción completa

Detalles Bibliográficos
Autores principales: Panzram, Benjamin, Bertlich, Ines, Reiner, Tobias, Walker, Tilman, Hagmann, Sébastien, Weber, Marc-André, Gotterbarm, Tobias
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5245886/
https://www.ncbi.nlm.nih.gov/pubmed/28103308
http://dx.doi.org/10.1371/journal.pone.0170324
_version_ 1782496900112449536
author Panzram, Benjamin
Bertlich, Ines
Reiner, Tobias
Walker, Tilman
Hagmann, Sébastien
Weber, Marc-André
Gotterbarm, Tobias
author_facet Panzram, Benjamin
Bertlich, Ines
Reiner, Tobias
Walker, Tilman
Hagmann, Sébastien
Weber, Marc-André
Gotterbarm, Tobias
author_sort Panzram, Benjamin
collection PubMed
description PURPOSE: Tibial radiolucent lines (RL) are commonly seen in cemented unicompartmental knee replacement (UKR). In the postoperative course, they can be misinterpreted as signs of loosening, thus leading to unnecessary revision. Since 2004, a cementless OUKR is available. First studies and registry data have shown equally good clinical results of cementless OUKR compared to the cemented version and a significantly reduced incidence of RL in cementless implants. METHODS: This single-centre retrospective cohort study includes the first 30 UKR (27 patients) implanted between 2007 and 2009 with a mean follow-up of 5 years. Clinical outcome was evaluated using the OKS, AKS, range of movement (ROM) and level of pain (VAS). Standard radiologic evaluation was performed at three months, one and five years after surgery. The results five years after implantation were compared to a group of 27 cemented Oxford UKR (OUKR) in a matched-pair-analysis. RESULTS: Tibial RL were seen in 10 implants three months after operation, which significantly decreased to five after one year and to three after five years (p = 0.02). RL did not have a significant influence on revision (p = 1.0) or clinical outcome after five years. RL were always partial, never progressive and strictly limited to the tibia. There was no significant difference in the incidence of tibial RL five years after implantation between cemented and cementless implants (cemented: 4, cementless: 3, p = 1.0). CONCLUSIONS: After cementless implantation RL were limited to the tibia, partial and never progressive. During short term follow-up the incidence of RL decreased significantly. RL seem to have no influence on clinical outcome and revision.
format Online
Article
Text
id pubmed-5245886
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-52458862017-02-06 Results after Cementless Medial Oxford Unicompartmental Knee Replacement - Incidence of Radiolucent Lines Panzram, Benjamin Bertlich, Ines Reiner, Tobias Walker, Tilman Hagmann, Sébastien Weber, Marc-André Gotterbarm, Tobias PLoS One Research Article PURPOSE: Tibial radiolucent lines (RL) are commonly seen in cemented unicompartmental knee replacement (UKR). In the postoperative course, they can be misinterpreted as signs of loosening, thus leading to unnecessary revision. Since 2004, a cementless OUKR is available. First studies and registry data have shown equally good clinical results of cementless OUKR compared to the cemented version and a significantly reduced incidence of RL in cementless implants. METHODS: This single-centre retrospective cohort study includes the first 30 UKR (27 patients) implanted between 2007 and 2009 with a mean follow-up of 5 years. Clinical outcome was evaluated using the OKS, AKS, range of movement (ROM) and level of pain (VAS). Standard radiologic evaluation was performed at three months, one and five years after surgery. The results five years after implantation were compared to a group of 27 cemented Oxford UKR (OUKR) in a matched-pair-analysis. RESULTS: Tibial RL were seen in 10 implants three months after operation, which significantly decreased to five after one year and to three after five years (p = 0.02). RL did not have a significant influence on revision (p = 1.0) or clinical outcome after five years. RL were always partial, never progressive and strictly limited to the tibia. There was no significant difference in the incidence of tibial RL five years after implantation between cemented and cementless implants (cemented: 4, cementless: 3, p = 1.0). CONCLUSIONS: After cementless implantation RL were limited to the tibia, partial and never progressive. During short term follow-up the incidence of RL decreased significantly. RL seem to have no influence on clinical outcome and revision. Public Library of Science 2017-01-19 /pmc/articles/PMC5245886/ /pubmed/28103308 http://dx.doi.org/10.1371/journal.pone.0170324 Text en © 2017 Panzram et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Panzram, Benjamin
Bertlich, Ines
Reiner, Tobias
Walker, Tilman
Hagmann, Sébastien
Weber, Marc-André
Gotterbarm, Tobias
Results after Cementless Medial Oxford Unicompartmental Knee Replacement - Incidence of Radiolucent Lines
title Results after Cementless Medial Oxford Unicompartmental Knee Replacement - Incidence of Radiolucent Lines
title_full Results after Cementless Medial Oxford Unicompartmental Knee Replacement - Incidence of Radiolucent Lines
title_fullStr Results after Cementless Medial Oxford Unicompartmental Knee Replacement - Incidence of Radiolucent Lines
title_full_unstemmed Results after Cementless Medial Oxford Unicompartmental Knee Replacement - Incidence of Radiolucent Lines
title_short Results after Cementless Medial Oxford Unicompartmental Knee Replacement - Incidence of Radiolucent Lines
title_sort results after cementless medial oxford unicompartmental knee replacement - incidence of radiolucent lines
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5245886/
https://www.ncbi.nlm.nih.gov/pubmed/28103308
http://dx.doi.org/10.1371/journal.pone.0170324
work_keys_str_mv AT panzrambenjamin resultsaftercementlessmedialoxfordunicompartmentalkneereplacementincidenceofradiolucentlines
AT bertlichines resultsaftercementlessmedialoxfordunicompartmentalkneereplacementincidenceofradiolucentlines
AT reinertobias resultsaftercementlessmedialoxfordunicompartmentalkneereplacementincidenceofradiolucentlines
AT walkertilman resultsaftercementlessmedialoxfordunicompartmentalkneereplacementincidenceofradiolucentlines
AT hagmannsebastien resultsaftercementlessmedialoxfordunicompartmentalkneereplacementincidenceofradiolucentlines
AT webermarcandre resultsaftercementlessmedialoxfordunicompartmentalkneereplacementincidenceofradiolucentlines
AT gotterbarmtobias resultsaftercementlessmedialoxfordunicompartmentalkneereplacementincidenceofradiolucentlines