Cargando…

Combining a hip arthroplasty stem with trochanteric reattachment bolt and a polyaxial locking plate in the treatment of a periprosthetic fracture below a well-integrated implant

Distally anchored uncemented modular tapered porous stems are often the preferred treatment in total hip arthroplasty revisions and failed subtrochanteric fractures. These conditions mainly affect elderly osteoporotic patients, with an increased risk of later fractures below the well-fixated implant...

Descripción completa

Detalles Bibliográficos
Autores principales: Hedlundh, Urban, Karlsson, Lars
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5247515/
https://www.ncbi.nlm.nih.gov/pubmed/28326418
http://dx.doi.org/10.1016/j.artd.2016.02.002
_version_ 1782497096951136256
author Hedlundh, Urban
Karlsson, Lars
author_facet Hedlundh, Urban
Karlsson, Lars
author_sort Hedlundh, Urban
collection PubMed
description Distally anchored uncemented modular tapered porous stems are often the preferred treatment in total hip arthroplasty revisions and failed subtrochanteric fractures. These conditions mainly affect elderly osteoporotic patients, with an increased risk of later fractures below the well-fixated implant. Treatment in secondary fractures with long looking plates is the recommended treatment, where stability is a key to fracture healing. We report a complicated case in which this was achieved by an innovative technique combing the trochanteric attachment bolt of the stem system and a locking plate with polyaxial screws.
format Online
Article
Text
id pubmed-5247515
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-52475152017-03-21 Combining a hip arthroplasty stem with trochanteric reattachment bolt and a polyaxial locking plate in the treatment of a periprosthetic fracture below a well-integrated implant Hedlundh, Urban Karlsson, Lars Arthroplasty Today Case Report Distally anchored uncemented modular tapered porous stems are often the preferred treatment in total hip arthroplasty revisions and failed subtrochanteric fractures. These conditions mainly affect elderly osteoporotic patients, with an increased risk of later fractures below the well-fixated implant. Treatment in secondary fractures with long looking plates is the recommended treatment, where stability is a key to fracture healing. We report a complicated case in which this was achieved by an innovative technique combing the trochanteric attachment bolt of the stem system and a locking plate with polyaxial screws. Elsevier 2016-03-02 /pmc/articles/PMC5247515/ /pubmed/28326418 http://dx.doi.org/10.1016/j.artd.2016.02.002 Text en © 2016 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Case Report
Hedlundh, Urban
Karlsson, Lars
Combining a hip arthroplasty stem with trochanteric reattachment bolt and a polyaxial locking plate in the treatment of a periprosthetic fracture below a well-integrated implant
title Combining a hip arthroplasty stem with trochanteric reattachment bolt and a polyaxial locking plate in the treatment of a periprosthetic fracture below a well-integrated implant
title_full Combining a hip arthroplasty stem with trochanteric reattachment bolt and a polyaxial locking plate in the treatment of a periprosthetic fracture below a well-integrated implant
title_fullStr Combining a hip arthroplasty stem with trochanteric reattachment bolt and a polyaxial locking plate in the treatment of a periprosthetic fracture below a well-integrated implant
title_full_unstemmed Combining a hip arthroplasty stem with trochanteric reattachment bolt and a polyaxial locking plate in the treatment of a periprosthetic fracture below a well-integrated implant
title_short Combining a hip arthroplasty stem with trochanteric reattachment bolt and a polyaxial locking plate in the treatment of a periprosthetic fracture below a well-integrated implant
title_sort combining a hip arthroplasty stem with trochanteric reattachment bolt and a polyaxial locking plate in the treatment of a periprosthetic fracture below a well-integrated implant
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5247515/
https://www.ncbi.nlm.nih.gov/pubmed/28326418
http://dx.doi.org/10.1016/j.artd.2016.02.002
work_keys_str_mv AT hedlundhurban combiningahiparthroplastystemwithtrochantericreattachmentboltandapolyaxiallockingplateinthetreatmentofaperiprostheticfracturebelowawellintegratedimplant
AT karlssonlars combiningahiparthroplastystemwithtrochantericreattachmentboltandapolyaxiallockingplateinthetreatmentofaperiprostheticfracturebelowawellintegratedimplant