Cargando…

Use of locking plates for fixation of the greater trochanter in patients with hip replacement

BACKGROUND: Fixation of the greater trochanter with total hip replacement is challenging and associated with short- and long-term complications. Locking plate technology has been used for fixation of other bones and may be applied successfully in trochanteric fixation. The purpose of this retrospect...

Descripción completa

Detalles Bibliográficos
Autores principales: Tetreault, Allison K., McGrory, Brian J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5247560/
https://www.ncbi.nlm.nih.gov/pubmed/28326426
http://dx.doi.org/10.1016/j.artd.2016.09.006
_version_ 1782497105341841408
author Tetreault, Allison K.
McGrory, Brian J.
author_facet Tetreault, Allison K.
McGrory, Brian J.
author_sort Tetreault, Allison K.
collection PubMed
description BACKGROUND: Fixation of the greater trochanter with total hip replacement is challenging and associated with short- and long-term complications. Locking plate technology has been used for fixation of other bones and may be applied successfully in trochanteric fixation. The purpose of this retrospective study was to analyze the utility of the use of trochanteric locking plates in total hip arthroplasty (THA) patients. METHODS: From 2004 to 2014, 32 procedures were performed to fix the greater trochanter in patients with trochanteric fracture, osteotomy, or nonunion in the setting of THA. The median age at the time of surgery was 69 years. This was a primary arthroplasty in 8 of the patients, conversion from prior hip surgery in 5, and a revision in 19. The greater trochanter was fixed with locking plate alone in 15 hips and with the addition of a single cerclage cable in 17 hips. Patients were followed clinically and radiographically until healing occurred. The median duration of radiographic follow-up was 41.6 months (range: 10-112 months). RESULTS: Osseous union occurred in 29 (90.6%) of 32 hips. The median Harris hip score was 94 (range 54-100, standard deviation = 10.4) at latest follow-up. Complications included broken hardware in 5 (15.6%) patients, of which 3 underwent subsequent hardware removal. Two additional patients elected hardware removal due to trochanteric pain. CONCLUSIONS: Locking plate technology is a successful method of fixation of the greater trochanter in patients with THA. Postoperative trochanteric pain and reoperation for hardware-related issues remain a challenge.
format Online
Article
Text
id pubmed-5247560
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-52475602017-03-21 Use of locking plates for fixation of the greater trochanter in patients with hip replacement Tetreault, Allison K. McGrory, Brian J. Arthroplasty Today Original Research BACKGROUND: Fixation of the greater trochanter with total hip replacement is challenging and associated with short- and long-term complications. Locking plate technology has been used for fixation of other bones and may be applied successfully in trochanteric fixation. The purpose of this retrospective study was to analyze the utility of the use of trochanteric locking plates in total hip arthroplasty (THA) patients. METHODS: From 2004 to 2014, 32 procedures were performed to fix the greater trochanter in patients with trochanteric fracture, osteotomy, or nonunion in the setting of THA. The median age at the time of surgery was 69 years. This was a primary arthroplasty in 8 of the patients, conversion from prior hip surgery in 5, and a revision in 19. The greater trochanter was fixed with locking plate alone in 15 hips and with the addition of a single cerclage cable in 17 hips. Patients were followed clinically and radiographically until healing occurred. The median duration of radiographic follow-up was 41.6 months (range: 10-112 months). RESULTS: Osseous union occurred in 29 (90.6%) of 32 hips. The median Harris hip score was 94 (range 54-100, standard deviation = 10.4) at latest follow-up. Complications included broken hardware in 5 (15.6%) patients, of which 3 underwent subsequent hardware removal. Two additional patients elected hardware removal due to trochanteric pain. CONCLUSIONS: Locking plate technology is a successful method of fixation of the greater trochanter in patients with THA. Postoperative trochanteric pain and reoperation for hardware-related issues remain a challenge. Elsevier 2016-10-13 /pmc/articles/PMC5247560/ /pubmed/28326426 http://dx.doi.org/10.1016/j.artd.2016.09.006 Text en © 2016 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Research
Tetreault, Allison K.
McGrory, Brian J.
Use of locking plates for fixation of the greater trochanter in patients with hip replacement
title Use of locking plates for fixation of the greater trochanter in patients with hip replacement
title_full Use of locking plates for fixation of the greater trochanter in patients with hip replacement
title_fullStr Use of locking plates for fixation of the greater trochanter in patients with hip replacement
title_full_unstemmed Use of locking plates for fixation of the greater trochanter in patients with hip replacement
title_short Use of locking plates for fixation of the greater trochanter in patients with hip replacement
title_sort use of locking plates for fixation of the greater trochanter in patients with hip replacement
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5247560/
https://www.ncbi.nlm.nih.gov/pubmed/28326426
http://dx.doi.org/10.1016/j.artd.2016.09.006
work_keys_str_mv AT tetreaultallisonk useoflockingplatesforfixationofthegreatertrochanterinpatientswithhipreplacement
AT mcgrorybrianj useoflockingplatesforfixationofthegreatertrochanterinpatientswithhipreplacement