Cargando…

The effect of fresh gas flow rate and type of anesthesia machine on time to reach target sevoflurane concentration

BACKGROUND: Anesthesia machines have been developed by the application of new technology for rapid and easier control of anesthetic concentration. In this study, we used a test lung to investigate whether the time taken to reach the target sevoflurane concentration varies with the rate of fresh gas...

Descripción completa

Detalles Bibliográficos
Autores principales: Shin, Hye Won, Yu, Hae Na, Bae, Go Eun, Huh, Hyub, Park, Ji Yong, Kim, Ji Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5248460/
https://www.ncbi.nlm.nih.gov/pubmed/28103806
http://dx.doi.org/10.1186/s12871-016-0294-y
_version_ 1782497271886118912
author Shin, Hye Won
Yu, Hae Na
Bae, Go Eun
Huh, Hyub
Park, Ji Yong
Kim, Ji Young
author_facet Shin, Hye Won
Yu, Hae Na
Bae, Go Eun
Huh, Hyub
Park, Ji Yong
Kim, Ji Young
author_sort Shin, Hye Won
collection PubMed
description BACKGROUND: Anesthesia machines have been developed by the application of new technology for rapid and easier control of anesthetic concentration. In this study, we used a test lung to investigate whether the time taken to reach the target sevoflurane concentration varies with the rate of fresh gas flow (FGF) and type of anesthesia machine (AM). METHODS: We measured the times taken to reach the target sevoflurane concentration (2 minimum alveolar concentration = 4%) at variable rates of FGF (0.5, 1, or 3 L/min) and different types of AM (Primus(®), Perseus(®), and Zeus(®) [Zeus(®)-F; Zeus(®) fresh gas mode, Zeus(®)-A; Zeus(®) auto-mode]). Concomitant ventilation was supplied using 100% O(2.) The AMs were connected to a test lung. A sevoflurane vaporizer setting of 6% was used in Primus(®), Perseus(®), and Zeus(®)-F; a target end-tidal setting of 4% was used in Zeus(®)-A (from a vaporizer setting of 0%). The time taken to reach the target concentration was measured in every group. RESULTS: When the same AM was used (Primus(®), Perseus(®), or Zeus(®)-F), the times to target concentration shortened as the FGF rate increased (P < 0.05). Conversely, when the same FGF rate was used, but with different AMs, the time to target concentration was shortest in Perseus(®), followed by Primus(®), and finally by Zeus(®)-F (P < 0.05). With regards to both modes of Zeus(®), at FGF rates of 0.5 and 1 L/min, the time to target concentration was shorter in Zeus(®)-A than in Zeus(®)-F; however, the time was longer in Zeus(®)-A than in Zeus(®)-F at FGF rate of 3 L/min (P < 0.05). CONCLUSION: Shorter times taken to reach the target concentration were associated with high FGF rates, smaller internal volume of the AM, proximity of the fresh gas inlets to patients, absence of a decoupling system, and use of blower-driven ventilators in AM.
format Online
Article
Text
id pubmed-5248460
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-52484602017-01-25 The effect of fresh gas flow rate and type of anesthesia machine on time to reach target sevoflurane concentration Shin, Hye Won Yu, Hae Na Bae, Go Eun Huh, Hyub Park, Ji Yong Kim, Ji Young BMC Anesthesiol Research Article BACKGROUND: Anesthesia machines have been developed by the application of new technology for rapid and easier control of anesthetic concentration. In this study, we used a test lung to investigate whether the time taken to reach the target sevoflurane concentration varies with the rate of fresh gas flow (FGF) and type of anesthesia machine (AM). METHODS: We measured the times taken to reach the target sevoflurane concentration (2 minimum alveolar concentration = 4%) at variable rates of FGF (0.5, 1, or 3 L/min) and different types of AM (Primus(®), Perseus(®), and Zeus(®) [Zeus(®)-F; Zeus(®) fresh gas mode, Zeus(®)-A; Zeus(®) auto-mode]). Concomitant ventilation was supplied using 100% O(2.) The AMs were connected to a test lung. A sevoflurane vaporizer setting of 6% was used in Primus(®), Perseus(®), and Zeus(®)-F; a target end-tidal setting of 4% was used in Zeus(®)-A (from a vaporizer setting of 0%). The time taken to reach the target concentration was measured in every group. RESULTS: When the same AM was used (Primus(®), Perseus(®), or Zeus(®)-F), the times to target concentration shortened as the FGF rate increased (P < 0.05). Conversely, when the same FGF rate was used, but with different AMs, the time to target concentration was shortest in Perseus(®), followed by Primus(®), and finally by Zeus(®)-F (P < 0.05). With regards to both modes of Zeus(®), at FGF rates of 0.5 and 1 L/min, the time to target concentration was shorter in Zeus(®)-A than in Zeus(®)-F; however, the time was longer in Zeus(®)-A than in Zeus(®)-F at FGF rate of 3 L/min (P < 0.05). CONCLUSION: Shorter times taken to reach the target concentration were associated with high FGF rates, smaller internal volume of the AM, proximity of the fresh gas inlets to patients, absence of a decoupling system, and use of blower-driven ventilators in AM. BioMed Central 2017-01-19 /pmc/articles/PMC5248460/ /pubmed/28103806 http://dx.doi.org/10.1186/s12871-016-0294-y Text en © The Author(s). 2017 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Shin, Hye Won
Yu, Hae Na
Bae, Go Eun
Huh, Hyub
Park, Ji Yong
Kim, Ji Young
The effect of fresh gas flow rate and type of anesthesia machine on time to reach target sevoflurane concentration
title The effect of fresh gas flow rate and type of anesthesia machine on time to reach target sevoflurane concentration
title_full The effect of fresh gas flow rate and type of anesthesia machine on time to reach target sevoflurane concentration
title_fullStr The effect of fresh gas flow rate and type of anesthesia machine on time to reach target sevoflurane concentration
title_full_unstemmed The effect of fresh gas flow rate and type of anesthesia machine on time to reach target sevoflurane concentration
title_short The effect of fresh gas flow rate and type of anesthesia machine on time to reach target sevoflurane concentration
title_sort effect of fresh gas flow rate and type of anesthesia machine on time to reach target sevoflurane concentration
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5248460/
https://www.ncbi.nlm.nih.gov/pubmed/28103806
http://dx.doi.org/10.1186/s12871-016-0294-y
work_keys_str_mv AT shinhyewon theeffectoffreshgasflowrateandtypeofanesthesiamachineontimetoreachtargetsevofluraneconcentration
AT yuhaena theeffectoffreshgasflowrateandtypeofanesthesiamachineontimetoreachtargetsevofluraneconcentration
AT baegoeun theeffectoffreshgasflowrateandtypeofanesthesiamachineontimetoreachtargetsevofluraneconcentration
AT huhhyub theeffectoffreshgasflowrateandtypeofanesthesiamachineontimetoreachtargetsevofluraneconcentration
AT parkjiyong theeffectoffreshgasflowrateandtypeofanesthesiamachineontimetoreachtargetsevofluraneconcentration
AT kimjiyoung theeffectoffreshgasflowrateandtypeofanesthesiamachineontimetoreachtargetsevofluraneconcentration
AT shinhyewon effectoffreshgasflowrateandtypeofanesthesiamachineontimetoreachtargetsevofluraneconcentration
AT yuhaena effectoffreshgasflowrateandtypeofanesthesiamachineontimetoreachtargetsevofluraneconcentration
AT baegoeun effectoffreshgasflowrateandtypeofanesthesiamachineontimetoreachtargetsevofluraneconcentration
AT huhhyub effectoffreshgasflowrateandtypeofanesthesiamachineontimetoreachtargetsevofluraneconcentration
AT parkjiyong effectoffreshgasflowrateandtypeofanesthesiamachineontimetoreachtargetsevofluraneconcentration
AT kimjiyoung effectoffreshgasflowrateandtypeofanesthesiamachineontimetoreachtargetsevofluraneconcentration