Cargando…

Assessment of transfemoral amputees using a passive microprocessor-controlled knee versus an active powered microprocessor-controlled knee for level walking

BACKGROUND: In transfemoral (TF) amputees, the forward propulsion of the prosthetic leg in swing has to be mainly carried out by hip muscles. With hip strength being the strongest predictor to ambulation ability, an active powered knee joint could have a positive influence, lowering hip loading and...

Descripción completa

Detalles Bibliográficos
Autores principales: Creylman, Veerle, Knippels, Ingrid, Janssen, Paul, Biesbrouck, Evelyne, Lechler, Knut, Peeraer, Louis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5249022/
https://www.ncbi.nlm.nih.gov/pubmed/28105945
http://dx.doi.org/10.1186/s12938-016-0287-6
_version_ 1782497373816094720
author Creylman, Veerle
Knippels, Ingrid
Janssen, Paul
Biesbrouck, Evelyne
Lechler, Knut
Peeraer, Louis
author_facet Creylman, Veerle
Knippels, Ingrid
Janssen, Paul
Biesbrouck, Evelyne
Lechler, Knut
Peeraer, Louis
author_sort Creylman, Veerle
collection PubMed
description BACKGROUND: In transfemoral (TF) amputees, the forward propulsion of the prosthetic leg in swing has to be mainly carried out by hip muscles. With hip strength being the strongest predictor to ambulation ability, an active powered knee joint could have a positive influence, lowering hip loading and contributing to ambulation mobility. To assess this, gait of four TF amputees was measured for level walking, first while using a passive microprocessor-controlled prosthetic knee (P-MPK), subsequently while using an active powered microprocessor-controlled prosthetic knee (A-MPK). Furthermore, to assess long-term effects of the use of an A-MPK, a 4-weeks follow-up case study was performed. METHODS: The kinetics and kinematics of the gait of four TF amputees were assessed while walking with subsequently the P-MPK and the A-MPK. For one amputee, a follow-up study was performed: he used the A-MPK for 4 weeks, his gait was measured weekly. RESULTS: The range of motion of the knee was higher on both the prosthetic and the sound leg in the A-MPK compared to the P-MPK. Maximum hip torque (HT) during early stance increased for the prosthetic leg and decreased for the sound leg with the A-MPK compared to the P-MPK. During late stance, the maximum HT decreased for the prosthetic leg. The difference between prosthetic and sound leg for HT disappeared when using the A-MPK. Also, an increase in stance phase duration was observed. The follow-up study showed an increase in confidence with the A-MPK over time. CONCLUSIONS: Results suggested that, partially due to an induced knee flexion during stance, HT can be diminished when walking with the A-MPK compared to the P-MPK. The single case follow-up study showed positive trends indicating that an adaptation time is beneficial for the A-MPK.
format Online
Article
Text
id pubmed-5249022
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-52490222017-01-26 Assessment of transfemoral amputees using a passive microprocessor-controlled knee versus an active powered microprocessor-controlled knee for level walking Creylman, Veerle Knippels, Ingrid Janssen, Paul Biesbrouck, Evelyne Lechler, Knut Peeraer, Louis Biomed Eng Online Research BACKGROUND: In transfemoral (TF) amputees, the forward propulsion of the prosthetic leg in swing has to be mainly carried out by hip muscles. With hip strength being the strongest predictor to ambulation ability, an active powered knee joint could have a positive influence, lowering hip loading and contributing to ambulation mobility. To assess this, gait of four TF amputees was measured for level walking, first while using a passive microprocessor-controlled prosthetic knee (P-MPK), subsequently while using an active powered microprocessor-controlled prosthetic knee (A-MPK). Furthermore, to assess long-term effects of the use of an A-MPK, a 4-weeks follow-up case study was performed. METHODS: The kinetics and kinematics of the gait of four TF amputees were assessed while walking with subsequently the P-MPK and the A-MPK. For one amputee, a follow-up study was performed: he used the A-MPK for 4 weeks, his gait was measured weekly. RESULTS: The range of motion of the knee was higher on both the prosthetic and the sound leg in the A-MPK compared to the P-MPK. Maximum hip torque (HT) during early stance increased for the prosthetic leg and decreased for the sound leg with the A-MPK compared to the P-MPK. During late stance, the maximum HT decreased for the prosthetic leg. The difference between prosthetic and sound leg for HT disappeared when using the A-MPK. Also, an increase in stance phase duration was observed. The follow-up study showed an increase in confidence with the A-MPK over time. CONCLUSIONS: Results suggested that, partially due to an induced knee flexion during stance, HT can be diminished when walking with the A-MPK compared to the P-MPK. The single case follow-up study showed positive trends indicating that an adaptation time is beneficial for the A-MPK. BioMed Central 2016-12-19 /pmc/articles/PMC5249022/ /pubmed/28105945 http://dx.doi.org/10.1186/s12938-016-0287-6 Text en © The Author(s) 2016 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research
Creylman, Veerle
Knippels, Ingrid
Janssen, Paul
Biesbrouck, Evelyne
Lechler, Knut
Peeraer, Louis
Assessment of transfemoral amputees using a passive microprocessor-controlled knee versus an active powered microprocessor-controlled knee for level walking
title Assessment of transfemoral amputees using a passive microprocessor-controlled knee versus an active powered microprocessor-controlled knee for level walking
title_full Assessment of transfemoral amputees using a passive microprocessor-controlled knee versus an active powered microprocessor-controlled knee for level walking
title_fullStr Assessment of transfemoral amputees using a passive microprocessor-controlled knee versus an active powered microprocessor-controlled knee for level walking
title_full_unstemmed Assessment of transfemoral amputees using a passive microprocessor-controlled knee versus an active powered microprocessor-controlled knee for level walking
title_short Assessment of transfemoral amputees using a passive microprocessor-controlled knee versus an active powered microprocessor-controlled knee for level walking
title_sort assessment of transfemoral amputees using a passive microprocessor-controlled knee versus an active powered microprocessor-controlled knee for level walking
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5249022/
https://www.ncbi.nlm.nih.gov/pubmed/28105945
http://dx.doi.org/10.1186/s12938-016-0287-6
work_keys_str_mv AT creylmanveerle assessmentoftransfemoralamputeesusingapassivemicroprocessorcontrolledkneeversusanactivepoweredmicroprocessorcontrolledkneeforlevelwalking
AT knippelsingrid assessmentoftransfemoralamputeesusingapassivemicroprocessorcontrolledkneeversusanactivepoweredmicroprocessorcontrolledkneeforlevelwalking
AT janssenpaul assessmentoftransfemoralamputeesusingapassivemicroprocessorcontrolledkneeversusanactivepoweredmicroprocessorcontrolledkneeforlevelwalking
AT biesbrouckevelyne assessmentoftransfemoralamputeesusingapassivemicroprocessorcontrolledkneeversusanactivepoweredmicroprocessorcontrolledkneeforlevelwalking
AT lechlerknut assessmentoftransfemoralamputeesusingapassivemicroprocessorcontrolledkneeversusanactivepoweredmicroprocessorcontrolledkneeforlevelwalking
AT peeraerlouis assessmentoftransfemoralamputeesusingapassivemicroprocessorcontrolledkneeversusanactivepoweredmicroprocessorcontrolledkneeforlevelwalking