Cargando…

Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial

BACKGROUND: Positive end-expiratory pressure (PEEP) can increase intracranial pressure. Pneumoperitoneum and the Trendelenburg position are associated with an increased intracranial pressure. We investigated whether PEEP ventilation could additionally influence the sonographic optic nerve sheath dia...

Descripción completa

Detalles Bibliográficos
Autores principales: Chin, Ji-Hyun, Kim, Wook-Jong, Lee, Joonho, Han, Yun A., Lim, Jinwook, Hwang, Jai-Hyun, Cho, Seong-Sik, Kim, Young-Kug
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Public Library of Science 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5249217/
https://www.ncbi.nlm.nih.gov/pubmed/28107408
http://dx.doi.org/10.1371/journal.pone.0170369
_version_ 1782497417642377216
author Chin, Ji-Hyun
Kim, Wook-Jong
Lee, Joonho
Han, Yun A.
Lim, Jinwook
Hwang, Jai-Hyun
Cho, Seong-Sik
Kim, Young-Kug
author_facet Chin, Ji-Hyun
Kim, Wook-Jong
Lee, Joonho
Han, Yun A.
Lim, Jinwook
Hwang, Jai-Hyun
Cho, Seong-Sik
Kim, Young-Kug
author_sort Chin, Ji-Hyun
collection PubMed
description BACKGROUND: Positive end-expiratory pressure (PEEP) can increase intracranial pressure. Pneumoperitoneum and the Trendelenburg position are associated with an increased intracranial pressure. We investigated whether PEEP ventilation could additionally influence the sonographic optic nerve sheath diameter as a surrogate for intracranial pressure during pneumoperitoneum combined with the Trendelenburg position in patients undergoing robot-assisted laparoscopic prostatectomy. METHODS: After anesthetic induction, 38 patients were randomly allocated to a low tidal volume ventilation (8 ml/kg) without PEEP group (zero end-expiratory pressure [ZEEP] group, n = 19) or low tidal volume ventilation with 8 cmH(2)O PEEP group (PEEP group, n = 19). The sonographic optic nerve sheath diameter was measured prior to skin incision, 5 min and 30 min after pneumoperitoneum and the Trendelenburg position, and at the end of surgery. The study endpoint was the difference in the sonographic optic nerve sheath diameter 5 min after pneumoperitoneum and the Trendelenburg position between the ZEEP and PEEP groups. RESULTS: Optic nerve sheath diameters 5 min after pneumoperitoneum and the Trendelenburg position did not significantly differ between the groups [least square mean (95% confidence interval); 4.8 (4.6–4.9) mm vs 4.8 (4.7–5.0) mm, P = 0.618]. Optic nerve sheath diameters 30 min after pneumoperitoneum and the Trendelenburg position also did not differ between the groups [least square mean (95% confidence interval); 4.5 (4.3–4.6) mm vs 4.5 (4.4–4.6) mm, P = 0.733]. CONCLUSIONS: An 8 cmH(2)O PEEP application under low tidal volume ventilation does not induce an increase in the optic nerve sheath diameter during pneumoperitoneum combined with the steep Trendelenburg position, suggesting that there might be no detrimental effects of PEEP on the intracranial pressure during robot-assisted laparoscopic prostatectomy. TRIAL REGISTRATION: ClinicalTrial.gov NCT02516566
format Online
Article
Text
id pubmed-5249217
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Public Library of Science
record_format MEDLINE/PubMed
spelling pubmed-52492172017-02-06 Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial Chin, Ji-Hyun Kim, Wook-Jong Lee, Joonho Han, Yun A. Lim, Jinwook Hwang, Jai-Hyun Cho, Seong-Sik Kim, Young-Kug PLoS One Research Article BACKGROUND: Positive end-expiratory pressure (PEEP) can increase intracranial pressure. Pneumoperitoneum and the Trendelenburg position are associated with an increased intracranial pressure. We investigated whether PEEP ventilation could additionally influence the sonographic optic nerve sheath diameter as a surrogate for intracranial pressure during pneumoperitoneum combined with the Trendelenburg position in patients undergoing robot-assisted laparoscopic prostatectomy. METHODS: After anesthetic induction, 38 patients were randomly allocated to a low tidal volume ventilation (8 ml/kg) without PEEP group (zero end-expiratory pressure [ZEEP] group, n = 19) or low tidal volume ventilation with 8 cmH(2)O PEEP group (PEEP group, n = 19). The sonographic optic nerve sheath diameter was measured prior to skin incision, 5 min and 30 min after pneumoperitoneum and the Trendelenburg position, and at the end of surgery. The study endpoint was the difference in the sonographic optic nerve sheath diameter 5 min after pneumoperitoneum and the Trendelenburg position between the ZEEP and PEEP groups. RESULTS: Optic nerve sheath diameters 5 min after pneumoperitoneum and the Trendelenburg position did not significantly differ between the groups [least square mean (95% confidence interval); 4.8 (4.6–4.9) mm vs 4.8 (4.7–5.0) mm, P = 0.618]. Optic nerve sheath diameters 30 min after pneumoperitoneum and the Trendelenburg position also did not differ between the groups [least square mean (95% confidence interval); 4.5 (4.3–4.6) mm vs 4.5 (4.4–4.6) mm, P = 0.733]. CONCLUSIONS: An 8 cmH(2)O PEEP application under low tidal volume ventilation does not induce an increase in the optic nerve sheath diameter during pneumoperitoneum combined with the steep Trendelenburg position, suggesting that there might be no detrimental effects of PEEP on the intracranial pressure during robot-assisted laparoscopic prostatectomy. TRIAL REGISTRATION: ClinicalTrial.gov NCT02516566 Public Library of Science 2017-01-20 /pmc/articles/PMC5249217/ /pubmed/28107408 http://dx.doi.org/10.1371/journal.pone.0170369 Text en © 2017 Chin et al http://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Research Article
Chin, Ji-Hyun
Kim, Wook-Jong
Lee, Joonho
Han, Yun A.
Lim, Jinwook
Hwang, Jai-Hyun
Cho, Seong-Sik
Kim, Young-Kug
Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial
title Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial
title_full Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial
title_fullStr Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial
title_full_unstemmed Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial
title_short Effect of Positive End-Expiratory Pressure on the Sonographic Optic Nerve Sheath Diameter as a Surrogate for Intracranial Pressure during Robot-Assisted Laparoscopic Prostatectomy: A Randomized Controlled Trial
title_sort effect of positive end-expiratory pressure on the sonographic optic nerve sheath diameter as a surrogate for intracranial pressure during robot-assisted laparoscopic prostatectomy: a randomized controlled trial
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5249217/
https://www.ncbi.nlm.nih.gov/pubmed/28107408
http://dx.doi.org/10.1371/journal.pone.0170369
work_keys_str_mv AT chinjihyun effectofpositiveendexpiratorypressureonthesonographicopticnervesheathdiameterasasurrogateforintracranialpressureduringrobotassistedlaparoscopicprostatectomyarandomizedcontrolledtrial
AT kimwookjong effectofpositiveendexpiratorypressureonthesonographicopticnervesheathdiameterasasurrogateforintracranialpressureduringrobotassistedlaparoscopicprostatectomyarandomizedcontrolledtrial
AT leejoonho effectofpositiveendexpiratorypressureonthesonographicopticnervesheathdiameterasasurrogateforintracranialpressureduringrobotassistedlaparoscopicprostatectomyarandomizedcontrolledtrial
AT hanyuna effectofpositiveendexpiratorypressureonthesonographicopticnervesheathdiameterasasurrogateforintracranialpressureduringrobotassistedlaparoscopicprostatectomyarandomizedcontrolledtrial
AT limjinwook effectofpositiveendexpiratorypressureonthesonographicopticnervesheathdiameterasasurrogateforintracranialpressureduringrobotassistedlaparoscopicprostatectomyarandomizedcontrolledtrial
AT hwangjaihyun effectofpositiveendexpiratorypressureonthesonographicopticnervesheathdiameterasasurrogateforintracranialpressureduringrobotassistedlaparoscopicprostatectomyarandomizedcontrolledtrial
AT choseongsik effectofpositiveendexpiratorypressureonthesonographicopticnervesheathdiameterasasurrogateforintracranialpressureduringrobotassistedlaparoscopicprostatectomyarandomizedcontrolledtrial
AT kimyoungkug effectofpositiveendexpiratorypressureonthesonographicopticnervesheathdiameterasasurrogateforintracranialpressureduringrobotassistedlaparoscopicprostatectomyarandomizedcontrolledtrial